Daikin Ducted Air Conditioning Melbourne
A Daikin ducted reverse cycle system heats and cools the whole home from a concealed indoor unit in the roof, ceiling or under the floor, with air delivered to each room through ducts and discreet outlets. EZYAIR designs, supplies and installs Daikin ducted air conditioning across Melbourne.
Is Daikin ducted air conditioning right for your home?
Ducted air conditioning suits Melbourne homes that want even, quiet comfort in every room through cold winters and hot summers. Daikin notes that its Heating Focus models are ideal for cold climates such as Melbourne. A ducted system needs space for the indoor unit and ductwork, and a suitable location for the outdoor unit. If you only need to condition a few rooms, a Daikin multi split system or Daikin split system may suit better.
Current Daikin ducted ranges
The following ranges are listed on Daikin Australia's residential ducted page at the time of writing (October 2026).
- Daikin Premium Inverter Ducted
- Daikin Inverter Ducted
- Daikin Slimline Ducted
- Daikin Bulkhead
- Daikin Premium Inverter Ducted Underfloor
- Daikin Inverter Ducted Underfloor
EZYAIR is an independent air conditioning installer. Product information on this page is copied from Daikin Australia's official website and brochures. Figures are as published by the manufacturer. Where a figure is not published it is not shown. Tables scroll sideways on smaller screens.
Daikin Premium Inverter Ducted
Daikin's flagship ducted series, which Daikin describes as offering high energy performance, design flexibility and R22 retrofit capability.
- System: Reverse Cycle
- Capacities: 7.1kW, 8.5kW, 10.0kW, 12.5kW, 14.0kW, 16.0kW, 18.0kW, 20.0kW, 24.0kW
- Indoor Type: Ducted
- Power Supply: 1 Phase, 220-240v, 50Hz or 3 Phase, 380-415v, 50Hz
- Refrigerant: 7.1-20.0kW: R32 / 18.0-24.0kW: R410A
- Daikin notes that Heating Focus models (18.0 kW to 24.0 kW) offer improved heating performance and are ideal for cold climates such as Canberra, Hobart and Melbourne
- R22 retrofit capability is listed as not available for 18.0 kW, 20.0 kW and Heating Focus models
- Other features listed by Daikin: night time quiet mode, continuous operation up to 50°CDB ambient, Australian Made indoor units
- Controllers listed: Daikin AirHub and Daikin Airbase
Official Daikin Ducted Systems brochure (PDF) | Official range page
Specifications: Premium Inverter, single phase (7 models)
| INDOOR UNIT | FDYA71AV19 | FDYA85AV19 | FDYA100AV19 | FDYA125AV19 | FDYA140AV19 | FDYA160AV19 | FDYA180AV1 |
|---|---|---|---|---|---|---|---|
| OUTDOOR UNIT | RZAS71C2V1 | RZAS85C2V1 | RZAS100C2V1 | RZAS125C2V1 | RZAS140C2V1 | RZAS160C2V1 | RZAS180DV1 |
| Rated Capacity Cool (kW) | 7.1 | 8.5 | 10.0 | 12.5 | 14.0 | 16.0 | 18.0 |
| Rated Capacity Heat (kW) | 7.5 | 10.0 | 12.5 | 15.0 | 16.5 | 18.0 | 20.0 |
| Capacity Range Cool (kW) | 3.2-8.0 | 3.7-10.0 | 5.0-11.2 | 5.0-14.0 | 5.0-16.0 | 7.3-17.0 | 9.0-20.0 |
| Capacity Range Heat (kW) | 2.2-9.0 | 3.0-11.2 | 5.1-14.0 | 4.1-16.0 | 6.7-18.0 | 7.0-20.0 | 10.0-22.4 |
| Power Input (Rated) Cool (kW) | 1.90 | 2.35 | 2.61 | 3.45 | 3.93 | 4.85 | 5.16 |
| Power Input (Rated) Heat (kW) | 1.75 | 2.46 | 3.13 | 3.80 | 4.28 | 4.65 | 4.79 |
| E.E.R/C.O.P C/H | 3.74/4.29 | 3.62/4.07 | 3.83/3.99 | 3.62/3.95 | 3.56/3.86 | 3.30/3.87 | 3.49/4.18 |
| TCSPF (Residential) Hot/Average/Cold | 5.20/4.50/4.55 | 4.99/4.40/4.45 | 4.69/4.22/4.25 | 4.96/4.47/4.59 | 5.00/4.54/4.67 | 4.77/4.37/4.55 | 5.17/4.41/4.42 |
| HSPF (Residential) Hot/Average/Cold | 4.79/4.34/3.86 | 4.43/4.04/3.60 | 4.43/4.07/3.62 | 4.72/4.08/3.45 | 5.01/4.12/3.41 | 4.55/3.97/3.41 | 5.33/4.52/3.82 |
| Airflow Rate (Nominal/Max) l/s | 425/566 | 580/600 | 680/800 | 755/840 | 900/1000 | 950/1120 | 1160/1200 |
| Indoor Sound Level (H) @ 1.5m dBA (C/H) | 37.3/40.5 | 42.0/42.5 | 42.3/45.0 | 44.8/46.2 | 45.9/47.4 | 47.2/49.6 | 42.1/42.1 |
| Piping Length m | 75 | 50 | |||||
| Indoor Fan Speeds | H/M/L | ||||||
| Dimensions (HxWxD) Indoor (mm) | 300x1210x900 | 360x1520x935 | 400x1505x980 | 470x1200x997 | |||
| Dimensions (HxWxD) Outdoor (mm) | 990x940x320 | 1430x940x320 | |||||
| Weight Indoor (kg) | 40 | 41 | 46 | 56 | 60 | 60 | 70 |
| Weight Outdoor (kg) | 69 | 78 | 93 | 93 | 93 | 99 | 118 |
| Power Supply V/Hz | 1 Phase, 220-240V, 50Hz | ||||||
| Compressor Type | Hermetically Sealed Swing Type | ||||||
| Refrigerant | R32 | ||||||
| Pipe Sizes Liquid (mm) | 9.5 (Flared) | 9.5 (Brazed) | |||||
| Pipe Sizes Gas (mm) | 15.9 (Flared) | 19.1 (Brazed) | |||||
| Pipe Sizes Drain (mm) | ID 25 / OD 32 | BSP 3/4 inch Internal Thread | |||||
| Supply Air Opening mm (HxW, Flange) | 185x852 | 245x1152 | 295x1152 | 350x918 | |||
| Return Air Opening mm | 1x400 (Oval) | 2x350 (Oval) | 2x400 (Oval) | 393x918 (Flange) | |||
| Outdoor Operating Range Cool (ºCDB) | -5 to 50 | -5 to 52 | |||||
| Outdoor Operating Range Heat (ºCWB) | -15 to 15.5 | -20 to 15.5 | |||||
| EPA Sound Power Level dBA | 67 | 71 | 70 | 71 | 73 | 75 | 82 |
| Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) | 48/50 | 52/53 | 51/53 | 52/54 | 54/56 | 56/58 | 59/61 |
Source: Daikin Australia, Ducted Systems brochure (PDF), page 13. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Premium Inverter, three phase and Heating Focus (6 models)
| HEATING FOCUS OPTION | ||||||
|---|---|---|---|---|---|---|
| INDOOR UNIT | FDYA180AV1 | FDYA200AV1 | FDYQ250LCV1 | FDYQ180LCV1 | FDYQ200LCV1 | FDYQ250LCV1 |
| OUTDOOR UNIT | RZAS180DY1 | RZAS200DY1 | RZYQ10TY1 | RZYQ7TA2Y1 | RZYQ8TAY1 | RZYQ10TAY1 |
| Rated Capacity Cool (kW) | 18.0 | 20.0 | 24.0 | 18.0 | 20.0 | 24.0 |
| Rated Capacity Heat (kW) | 20.0 | 22.4 | 26.8 | 20.0 | 22.4 | 26.8 |
| Capacity Range Cool (kW) | 9.0-20.0 | 10.0-22.4 | 11.7-24.0 | 9.0-20.0 | 10.0-22.4 | 11.7-24.0 |
| Capacity Range Heat (kW) | 10.0-22.4 | 11.2-25.0 | 13.4-26.8 | 10.0-22.4 | 11.2-25.0 | 13.4-26.8 |
| Power Input (Rated) Cool (kW) | 5.09 | 5.94 | 7.47 | 5.60 | 6.08 | 7.47 |
| Power Input (Rated) Heat (kW) | 4.85 | 5.80 | 8.14 | 5.81 | 6.17 | 8.14 |
| E.E.R/C.O.P C/H | 3.54/4.12 | 3.37/3.86 | 3.21/3.29 | 3.21/3.44 | 3.29/3.63 | 3.21/3.29 |
| TCSPF (Residential) Hot/Average/Cold | 5.20/4.41/4.42 | 5.11/4.40/4.43 | 3.98/3.50/3.51 | 3.79/3.23/3.18 | 3.86/3.32/3.29 | 3.97/3.48/3.48 |
| HSPF (Residential) Hot/Average/Cold | 5.22/4.47/3.82 | 5.23/4.32/3.64 | 3.60/3.37/3.15 | 3.21/3.15/3.02 | 3.42/3.35/3.20 | 3.60/3.37/3.15 |
| Airflow Rate (Nominal/Max) l/s | 1160/1200 | 1200/1300 | 1400/1600 | 1160/1200 | 1200/1300 | 1400/1600 |
| Indoor Sound Level (H) @ 1.5m dBA (C/H) | 42.1/42.1 | 39.7/39.7 | 46.0/46.0 | 45.0/45.0 | 44.0/44.0 | 46.0/46.0 |
| Piping Length m | 50 | 150 | 165 | |||
| Indoor Fan Speeds | H/M/L | |||||
| Dimensions (HxWxD) Indoor (mm) | 470x1200x997 | 470x1400x997 | 470x1200x997 | 470x1400x997 | ||
| Dimensions (HxWxD) Outdoor (mm) | 1430x940x320 | 1657x930x765 | ||||
| Weight Indoor (kg) | 70 | 77 | 85 | 70 | 79 | 85 |
| Weight Outdoor (kg) | 118 | 118 | 203 | 185 | 185 | 200 |
| Power Supply V/Hz | 3 Phase, 380-415V, 50Hz | |||||
| Compressor Type | Hermetically Sealed Swing Type | Hermetically Sealed Scroll Type | ||||
| Refrigerant | R32 | R410A | ||||
| Pipe Sizes Liquid (mm) | 9.5 (Brazed) | |||||
| Pipe Sizes Gas (mm) | 19.1 (Brazed) | 22.2 (Brazed) | 19.1 (Brazed) | 22.2 (Brazed) | ||
| Pipe Sizes Drain (mm) | BSP 3/4 inch Internal Thread | |||||
| Supply Air Opening mm (HxW, Flange) | 350x918 | 350x1118 | 350x918 | 350x1118 | ||
| Return Air Opening mm | 393x918 (Flange) | 393x1118 (Flange) | 393x918 (Flange) | 393x1118 (Flange) | ||
| Outdoor Operating Range Cool (°CDB) | -5 to 52 | -5 to 49 | ||||
| Outdoor Operating Range Heat (°CWB) | -20 to 15.5 | |||||
| EPA Sound Power Level dBA | 82 | 82 | - | 76 | 76 | 78 |
| Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) | 59/61 | 59/61 | 57/57 | 56/56 | 56/56 | 57/57 |
Source: Daikin Australia, Ducted Systems brochure (PDF), page 13. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Daikin Inverter Ducted
A compact and efficient ducted series designed for the tight roof space of modern homes, with an indoor unit height of 360 mm or less (as published).
- System: Reverse Cycle
- Capacities: 5.0kW, 6.0kW, 7.1kW, 8.5kW, 10.0kW, 12.5kW, 14.0kW, 15.5kW, 18.0kW, 19.5kW, 20.0kW, 23.5kW
- Indoor Type: Ducted
- Power Supply: 1 Phase, 220-240v, 50Hz or 3 Phase, 380-415v, 50Hz
- Refrigerant: 5.0-15.5kW: R32 / 18.0-23.5kW: R410A
- Features listed by Daikin: night time quiet mode, R22 retrofit capability, Australian Made indoor units, space saving side discharge outdoor unit on models up to 19.5 kW
- Controllers listed: Daikin AirHub and Daikin Airbase
Official Daikin Ducted Systems brochure (PDF) | Official range page
Specifications: Inverter, single phase (8 models)
| INDOOR UNIT | FDYAN50AV1 | FDYAN60AV1 | FDYAN71AV1 | FDYAN85AV1 | FDYAN100AV1 | FDYAN125AV1 | FDYAN140AV1 | FDYAN160AV1 |
|---|---|---|---|---|---|---|---|---|
| OUTDOOR UNIT | RZA50C2V1 | RZA60C2V1 | RZA71C2V1 | RZA85C2V1 | RZA100C2V1 | RZA125C2V1 | RZA140C2V1 | RZA160C2V1 |
| Rated Capacity Cool (kW) | 5.0 | 6.0 | 7.1 | 8.5 | 10.0 | 12.5 | 14.0 | 15.5 |
| Rated Capacity Heat (kW) | 6.0 | 7.0 | 7.5 | 10.0 | 12.5 | 15.0 | 16.5 | 18.0 |
| Capacity Range Cool (kW) | 1.4-6.0 | 1.4-7.1 | 1.8-8.0 | 3.2-10.0 | 3.2-11.2 | 4.0-14.0 | 5.0-16.0 | 7.3-16.3 |
| Capacity Range Heat (kW) | 1.4-7.1 | 1.4-8.0 | 2.0-9.0 | 3.5-11.2 | 3.5-14.0 | 4.1-16.0 | 5.1-18.0 | 7.3-18.2 |
| Power Input (Rated) Cool (kW) | 1.35 | 1.78 | 2.20 | 2.53 | 3.10 | 3.94 | 4.30 | 4.95 |
| Power Input (Rated) Heat (kW) | 1.62 | 1.95 | 1.93 | 2.80 | 3.35 | 4.00 | 4.50 | 4.90 |
| E.E.R/C.O.P C/H | 3.70/3.70 | 3.37/3.59 | 3.23/3.89 | 3.36/3.57 | 3.23/3.73 | 3.17/3.75 | 3.26/3.67 | 3.13/3.67 |
| TCSPF (Residential) Hot/Average/ Cold | 4.42/3.72/3.65 | 4.35/3.75/3.75 | 4.42/3.86/3.92 | 4.28/3.84/3.89 | 4.28/3.87/3.96 | 4.25/3.90/4.01 | 4.19/3.86/3.96 | 4.05/3.76/3.86 |
| HSPF (Residential) Hot/Average/ Cold | 4.51/4.02/3.49 | 4.46/3.76/3.15 | 4.17/3.85/3.41 | 3.97/3.67/3.32 | 3.85/3.48/3.04 | 4.31/3.31/2.77 | 3.90/3.51/3.05 | 3.87/3.53/3.12 |
| Airflow Rate (Nominal/Max) l/s | 315/370 | 340/400 | 425/566 | 580/600 | 680/800 | 755/840 | 900/1000 | 950/1120 |
| Indoor Sound Level (H) @1.5m dBA (C/H) | 33.3/35.0 | 34.1/35.9 | 37.3/40.5 | 42.0/42.4 | 43.5/45.8 | 44.2/45.5 | 46.6/47.9 | 47.9/50.7 |
| Piping Length m | 50 | |||||||
| Indoor Fan Speeds | H/M/L | |||||||
| Dimensions (HxWxD) Indoor (mm) | 300x1210x900 | 360x1520x935 | ||||||
| Dimensions (HxWxD) Outdoor (mm) | 595x845x300 | 990x940x320 | 1430x940x320 | |||||
| Weight Indoor (kg) | 37 | 37 | 40 | 40 | 45 | 55 | 55 | 56 |
| Weight Outdoor (kg) | 45 | 45 | 45 | 69 | 69 | 78 | 93 | 99 |
| Power Supply V/Hz | 1 Phase, 220-240V, 50Hz | |||||||
| Compressor Type | Hermetically Sealed Swing Type | |||||||
| Refrigerant | R32 | |||||||
| Pipe Sizes Liquid (mm) | 6.4 (Flare) | 9.5 (Flare) | ||||||
| Pipe Sizes Gas (mm) | 12.7 (Flare) | 15.9 (Flare) | ||||||
| Pipe Sizes Drain (mm) | ID 25 / OD 32 | |||||||
| Supply Air Opening mm (HxW, Flange) | 185x852 | 245x1152 | ||||||
| Return Air Opening mm | 1x400 (Oval) | 2x350 (Oval) | 2x400 (Oval) | |||||
| Outdoor Operating Range Cool (ºCDB) | -5 to 46 | |||||||
| Outdoor Operating Range Heat (ºCWB) | -15 to 15.5 | |||||||
| EPA Sound Power Level dBA | 68 | 68 | 68 | 70 | 71 | 72 | 73 | 75 |
| Outdoor Sound Level (H) @1m Pressure dBA (C/H) | 48/51 | 48/51 | 48/51 | 51/54 | 52/54 | 53/56 | 54/56 | 56/58 |
Source: Daikin Australia, Ducted Systems brochure (PDF), page 14. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Inverter, three phase (9 models)
| INDOOR UNIT | FDYAN71AV1 | FDYAN85AV1 | FDYAN100AV1 | FDYAN125AV1 | FDYAN140AV1 | FDYAN160AV1 | FDYQN180LCV1 | FDYQN200LCV1 | FDYQN250LBV1 |
|---|---|---|---|---|---|---|---|---|---|
| OUTDOOR UNIT | RZA71C2Y1 | RZA85C2Y1 | RZA100C2Y1 | RZA125C2Y1 | RZA140C2Y1 | RZA160C2Y1 | RZQ180M2Y1 | RZQ200MY1 | RZQ250LY1 |
| Rated Capacity Cool (kW) | 7.1 | 8.5 | 10.0 | 12.5 | 14.0 | 15.5 | 18.0 | 19.5 | 23.5 |
| Rated Capacity Heat (kW) | 7.5 | 10.0 | 12.5 | 15.0 | 16.5 | 18.0 | 20.0 | 22.4 | 26.8 |
| Capacity Range Cool (kW) | 3.2-8.0 | 3.2-10.0 | 3.2-11.2 | 4.0-14.0 | 5.0-16.0 | 7.3-16.3 | 9.0-18.0 | 10.1-19.5 | 15.0-23.5 |
| Capacity Range Heat (kW) | 3.5-9.0 | 3.5-11.2 | 3.5-14.0 | 4.1-16.0 | 5.1-18.0 | 7.3-18.2 | 10.0-20.0 | 11.2-22.4 | 16.8-26.8 |
| Power Input (Rated) Cool (kW) | 2.20 | 2.53 | 3.10 | 3.94 | 4.30 | 4.95 | 5.82 | 6.11 | 7.85 |
| Power Input (Rated) Heat (kW) | 1.93 | 2.80 | 3.35 | 4.00 | 4.50 | 4.90 | 6.11 | 6.85 | 8.47 |
| E.E.R/C.O.P C/H | 3.23/3.89 | 3.36/3.57 | 3.23/3.73 | 3.17/3.75 | 3.26/3.67 | 3.13/3.67 | 3.09/3.27 | 3.19/3.27 | 2.99/3.16 |
| TCSPF (Residential) Hot/Average /Cold | 4.44/3.91/3.98 | 4.28/3.84/3.89 | 4.28/3.87/3.96 | 4.25/3.90/4.01 | 4.19/3.86/3.96 | 4.05/3.76/3.86 | 3.61/3.15/3.12 | 4.05/3.76/3.86 | 3.73/3.41/3.46 |
| HSPF (Residential) Hot/Average /Cold | 4.17/3.90/3.55 | 3.97/3.67/3.32 | 3.85/3.48/3.04 | 4.31/3.31/2.77 | 3.90/3.51/3.05 | 3.87/3.53/3.12 | 3.23/2.95/2.61 | 3.87/3.53/3.12 | 3.41/3.08/2.72 |
| Airflow Rate (Nominal/Max) l/s | 425/566 | 580/600 | 680/800 | 755/840 | 900/1000 | 950/1120 | 1160/1200 | 1400/1600 | 1400/1600 |
| Indoor Sound Level (H) @1.5m dBA (C/H) | 37.3/40.5 | 42.0/42.4 | 43.5/45.8 | 44.2/45.5 | 46.6/47.9 | 47.9/50.7 | 45.0/45.0 | 46.0/46.0 | 49.5/49.5 |
| Piping Length m | 50 | ||||||||
| Indoor Fan Speeds | H/M/L | ||||||||
| Dimensions (HxWxD) Indoor (mm) | 300x1210x900 | 360x1520x935 | 470x1200x997 | 470x1400x997 | 500x1430x970 | ||||
| Dimensions (HxWxD) Outdoor (mm) | 990x940x320 | 1430x940x320 | 1680x930x765 | ||||||
| Weight Indoor (kg) | 40 | 40 | 45 | 55 | 55 | 56 | 70 | 85 | 92 |
| Weight Outdoor (kg) | 69 | 69 | 69 | 78 | 93 | 99 | 138 | 138 | 193 |
| Power Supply V/Hz | 3 Phase, 380-415V, 50Hz | ||||||||
| Compressor Type | Hermetically Sealed Swing Type | Hermetically Sealed Scroll Type | |||||||
| Refrigerant | R32 | R410A | |||||||
| Pipe Sizes Liquid (mm) | 9.5 (Flare) | 9.5 (Brazed) | |||||||
| Pipe Sizes Gas (mm) | 15.9 (Flare) | 19.1 (Brazed) | 22.2 (Brazed) | ||||||
| Pipe Sizes Drain (mm) | ID 25/OD 32 | BSP 3/4 inch Internal Thread | |||||||
| Supply Air Opening mm (HxW, Flange) | 185x852 | 245x1152 | 350x918 | 350x1118 | 376x938 | ||||
| Return Air Opening mm | 1x400 (Oval) | 2x350 (Oval) | 2x400 (Oval) | 393x918 (Flange) | 393x1118 (Flange) | 350x1118 (Flange) | |||
| Outdoor Operating Range Cool (ºCDB) | -5 to 46 | -5 to 43 | |||||||
| Outdoor Operating Range Heat (ºCWB) | -15 to 15.5 | -20 to 15.5 | |||||||
| EPA Sound Power Level dBA | 67 | 70 | 71 | 72 | 73 | 75 | 72 | 74 | 79 |
| Outdoor Sound Level (H) @1m Pressure dBA (C/H) | 48/50 | 51/54 | 52/54 | 53/56 | 54/56 | 56/58 | 57/58 | 58/59 | 57/58 |
Source: Daikin Australia, Ducted Systems brochure (PDF), page 14. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Daikin Slimline Ducted
A low profile ducted series with an indoor unit height of 245 mm, designed for narrow ceiling spaces, apartments and under floor installation.
- System: Reverse Cycle
- Capacities: 5.0kW, 6.0kW, 7.1kW, 8.5kW, 10.0kW, 12.5kW, 14.0kW
- Indoor Type: Ducted
- Power Supply: 1 Phase, 220-240v, 50Hz or 3 Phase, 380-415v, 50Hz
- Refrigerant: R32
- Features listed by Daikin: static pressure of 150 Pa, up to 85 m of pipe run (100 to 140 class), automatic airflow adjustment, rear or bottom return air and a built in condensate pump
- Controllers listed: Nav Ease controller and zone controller
Official Daikin Ducted Systems brochure (PDF) | Official range page
Specifications: Slimline (FBA), single phase (9 models)
| SERIES | PREMIUM INVERTER | INVERTER | |||||||
|---|---|---|---|---|---|---|---|---|---|
| INDOOR UNIT | FBA50BAVMA | FBA60BAVMA | FBA71BVMA | FBA85BVMA | FBA100BVMA | FBA125BVMA | FBA140BVMA | FBA71BVMA | FBA85BVMA |
| OUTDOOR UNIT | RZAV50C2V1 | RZAV60C2V1 | RZAV71C2V1 | RZAV85C2V1 | RZAV100F2V1 | RZAV125F2V1 | RZAV140F2V1 | RZAC71C2V1 | RZAC85C2V1 |
| Rated Capacity Cool (kW) | 5.0 | 6.0 | 7.1 | 8.5 | 10.0 | 12.5 | 14.0 | 7.1 | 8.5 |
| Rated Capacity Heat (kW) | 6.0 | 7.1 | 8.0 | 10.0 | 12.0 | 15.0 | 16.5 | 8.0 | 10.0 |
| Capacity Range Cool (kW) | 1.4-6.0 | 1.4-7.1 | 3.2-8.0 | 4.0-10.0 | 3.5-11.5 | 3.5-14.0 | 3.5-15.0 | 1.8-8.0 | 3.2-10.0 |
| Capacity Range Heat (kW) | 1.4-7.1 | 1.4-8.0 | 3.5-9.0 | 4.1-11.2 | 3.5-14.0 | 3.5-16.5 | 3.5-18.0 | 2.0-9.0 | 3.5-11.2 |
| Power Input (Rated) Cool (kW) | 1.37 | 1.67 | 2.02 | 2.30 | 2.79 | 3.68 | 4.28 | 2.15 | 2.64 |
| Power Input (Rated) Heat (kW) | 1.41 | 1.71 | 1.99 | 2.50 | 2.92 | 3.88 | 4.52 | 2.30 | 2.95 |
| E.E.R/C.O.P C/H | 3.65/4.26 | 3.59/4.15 | 3.51/4.02 | 3.70/4.00 | 3.58/4.11 | 3.40/3.87 | 3.27/3.65 | 3.30/3.48 | 3.22/3.39 |
| TCSPF (Residential) Hot/Average /Cold | 4.63/3.87/3.83 | 4.58/3.92/3.91 | 4.52/3.97/4.00 | 4.79/4.26/4.31 | 5.55/4.92/5.07 | 5.03/4.62/4.76 | 4.90/4.53/4.69 | 4.18/3.67/3.69 | 4.32/3.87/3.95 |
| HSPF (Residential) Hot/Average /Cold | 5.01/4.57/4.11 | 4.94/4.47/3.96 | 4.49/4.14/3.71 | 4.64/4.27/3.87 | 5.57/4.75/4.18 | 5.32/4.49/3.88 | 5.24/4.35/3.77 | 3.96/3.68/3.42 | 4.24/3.83/3.49 |
| Airflow Rate (Nominal) l/s | 300 | 300 | 383 | 533 | 533 | 600 | 600 | 383 | 533 |
| Indoor Sound Level (H) @1.5m dBA | 35 | 35 | 38 | 38 | 38 | 40 | 40 | 38 | 38 |
| Piping Length m | 50 | 75 | 85 | 50 | |||||
| Indoor Fan Speeds | H/M/L | ||||||||
| Dimensions (HxWxD) Indoor (mm) | 245x1000x800 | 245x1400x800 | 245x1000x800 | 245x1400x800 | |||||
| Dimensions (HxWxD) Outdoor (mm) | 595x845x300 | 990x940x320 | 870x1100x460 | 595x845x300 | 990x940x320 | ||||
| Weight Indoor (kg) | 37 | 37 | 37 | 47 | 47 | 47 | 47 | 37 | 47 |
| Weight Outdoor (kg) | 45 | 45 | 69 | 78 | 93 | 95 | 95 | 45 | 69 |
| Power Supply V/Hz | 1 Phase, 220-240V, 50Hz | ||||||||
| Compressor Type | Hermetically Sealed Swing Type | ||||||||
| Refrigerant | R32 | ||||||||
| Pipe Sizes Liquid (mm) | 6.4 (Flared) | 9.5 (Flared) | |||||||
| Pipe Sizes Gas (mm) | 12.7 (Flared) | 15.9 (Flared) | |||||||
| Pipe Sizes Drain (mm) | ID 25 / OD 32 | ||||||||
| Supply Air Opening mm (HxW, Flange) | 176x792 | 176x1192 | 176x792 | 176x1192 | |||||
| Return Air Opening mm (HxW, Flange) | 208x952 | 208x1352 | 208x952 | 208x1352 | |||||
| Outdoor Operating Range Cool (ºCDB) | -5 to 50 | -5 to 46 | |||||||
| Outdoor Operating Range Heat (ºCWB) | -15 to 15.5 | ||||||||
| EPA Sound Power Level dBA | 68 | 68 | 67 | 71 | 68 | 69 | 70 | 68 | 70 |
| Outdoor Sound Level (H) @1m Pressure dBA (C/H) | 48/51 | 48/51 | 48/50 | 52/53 | 49/50 | 50/51 | 52/53 | 48/51 | 51/54 |
Source: Daikin Australia, Ducted Systems brochure (PDF), page 15. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Slimline (FBA), three phase (6 models)
| SERIES | PREMIUM INVERTER | INVERTER | ||||
|---|---|---|---|---|---|---|
| INDOOR UNIT | FBA71BVMA | FBA85BVMA | FBA100BVMA | FBA125BVMA | FBA140BVMA | FBA85BVMA |
| OUTDOOR UNIT | RZAV71C2Y1 | RZAV85C2Y1 | RZAV100F2Y1 | RZAV125F2Y1 | RZAV140F2Y1 | RZAC85C2Y1 |
| Rated Capacity Cool (kW) | 7.1 | 8.5 | 10.0 | 12.5 | 14.0 | 8.5 |
| Rated Capacity Heat (kW) | 8.0 | 10.0 | 12.0 | 15.0 | 16.5 | 10.0 |
| Capacity Range Cool (kW) | 3.2-8.0 | 4.0-10.0 | 3.5-11.5 | 3.5-14.0 | 3.5-15.0 | 3.2-10.0 |
| Capacity Range Heat (kW) | 3.5-9.0 | 4.1-11.2 | 3.5-14.0 | 3.5-16.5 | 3.5-18.0 | 3.5-11.2 |
| Power Input (Rated) Cool (kW) | 2.02 | 2.30 | 2.79 | 3.68 | 4.28 | 2.64 |
| Power Input (Rated) Heat (kW) | 1.99 | 2.50 | 2.92 | 3.88 | 4.52 | 2.95 |
| E.E.R/C.O.P C/H | 3.51/4.02 | 3.70/4.00 | 3.58/4.11 | 3.40/3.87 | 3.27/3.65 | 3.22/3.39 |
| TCSPF (Residential) Hot/Average/Cold | 4.52/3.97/4.00 | 4.79/4.26/4.31 | 5.55/4.92/5.07 | 5.03/4.62/4.76 | 4.90/4.53/4.69 | 4.32/3.87/3.95 |
| HSPF (Residential) Hot/Average/Cold | 4.49/4.14/3.71 | 4.64/4.27/3.87 | 5.57/4.75/4.18 | 5.32/4.49/3.88 | 5.24/4.35/3.77 | 4.24/3.83/3.49 |
| Airflow Rate (Nominal) l/s | 383 | 533 | 533 | 600 | 600 | 533 |
| Indoor Sound Level (H) @1.5m dBA | 38 | 38 | 38 | 40 | 40 | 38 |
| Piping Length m | 75 | 85 | 50 | |||
| Indoor Fan Speeds | H/M/L | |||||
| Dimensions (HxWxD) Indoor (mm) | 245x1000x800 | 245x1400x800 | ||||
| Dimensions (HxWxD) Outdoor (mm) | 990x940x320 | 870x1100x460 | 990x940x320 | |||
| Weight Indoor (kg) | 37 | 47 | 47 | 47 | 47 | 47 |
| Weight Outdoor (kg) | 69 | 78 | 93 | 95 | 95 | 69 |
| Power Supply V/Hz | 3 Phase, 380-415V, 50Hz | |||||
| Compressor Type | Hermetically Sealed Swing Type | |||||
| Refrigerant | R32 | |||||
| Pipe Sizes Liquid (mm) | 9.5 (Flared) | |||||
| Pipe Sizes Gas (mm) | 15.9 (Flared) | |||||
| Pipe Sizes Drain (mm) | ID 25 / OD 32 | |||||
| Supply Air Opening mm (HxW, Flange) | 176x792 | 176x1192 | ||||
| Return Air Opening mm (HxW, Flange) | 208x952 | 208x1352 | ||||
| Outdoor Operating Range Cool (ºCDB) | -5 to 50 | -5 to 46 | ||||
| Outdoor Operating Range Heat (ºCWB) | -15 to 15.5 | |||||
| EPA Sound Power Level dBA | 67 | 71 | 68 | 69 | 70 | 70 |
| Outdoor Sound Level (H) @1m Pressure dBA (C/H) | 48/50 | 52/53 | 49/50 | 50/51 | 52/53 | 51/54 |
Source: Daikin Australia, Ducted Systems brochure (PDF), page 15. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Daikin Bulkhead
A small ducted unit that fits flush into a bulkhead or ceiling, with only the suction and discharge grilles visible. Daikin notes a 450 mm deep indoor unit suited to wardrobe installations.
- System: Reverse Cycle
- Capacities: 2.5kW, 3.5kW, 5.0kW, 6.0kW, 7.1kW
- Indoor Type: Bulkhead
- Power Supply: 1 Phase, 220-240v, 50Hz
- Refrigerant: R32
- Daikin quotes a quiet operation level of 19 dBA (low fan speed, 35 class model)
- Controllers listed: wireless remote controller and Nav Ease controller
Official Daikin Ducted Systems brochure (PDF) | Official range page
Specifications: Bulkhead (FDYBA), single phase (5 models)
| INDOOR UNIT | FDYBA25AV1 | FDYBA35AV1 | FDYBA50AV1 | FDYBA60AV1 | FDYBA71AV1 |
|---|---|---|---|---|---|
| OUTDOOR UNIT | RZAC25G2V1 | RZAC35G2V1 | RZAC50G2V1 | RZAC60G2V1 | RZAC71G2V1 |
| Rated Capacity Cool (kW) | 2.50 | 3.50 | 5.00 | 6.00 | 7.10 |
| Rated Capacity Heat (kW) | 3.50 | 4.00 | 6.00 | 7.00 | 8.00 |
| Capacity Range Cool (kW) | 0.8-2.8 | 0.8-4.0 | 1.6-6.2 | 2.0-6.7 | 1.7-7.6 |
| Capacity Range Heat (kW) | 0.9-3.7 | 1.0-4.3 | 1.5-7.4 | 2.0-8.0 | 1.4-8.6 |
| Power Input (Rated) Cool (kW) | 0.60 | 1.02 | 1.37 | 1.70 | 2.12 |
| Power Input (Rated) Heat (kW) | 0.97 | 1.11 | 1.73 | 1.80 | 2.22 |
| E.E.R/C.O.P C/H | 4.17/3.61 | 3.45/3.60 | 3.65/3.47 | 3.53/3.89 | 3.35/3.60 |
| TCSPF (Residential) Hot/Average/Cold | 4.82/4.11/4.04 | 4.37/3.88/3.92 | 5.09/4.20/4.19 | 5.21/4.38/4.45 | 4.61/4.26/4.41 |
| HSPF (Residential) Hot/Average/Cold | 4.29/3.64/3.05 | 4.53/4.06/3.69 | 4.76/4.12/3.58 | 5.28/4.58/3.98 | 6.09/4.13/3.28 |
| Airflow Rate (Rated) l/s | 150 | 195 | 240 | 325 | 325 |
| Indoor Sound Level (H) @ 1.5m Discharge (dBA) | 41.6 | 43.1 | 45.3 | 47.7 | 47.7 |
| Indoor Sound Level (H) @ 1.5m Suction (dBA) | 40.8 | 38.9 | 41.2 | 46.2 | 46.2 |
| Indoor Sound Level (H) @ 1.5m Casing Breakout (dBA) | 30.1 | 31.6 | 33.8 | 35.6 | 35.6 |
| Piping Length m | 20 | 20 | 30 | 30 | 30 |
| Indoor Fan Speeds | 5 Steps, Quiet and Automatic | ||||
| Dimensions (HxWxD) Indoor (mm) | 200x700x450 | 200x900x450 | 200x1100x450 | ||
| Dimensions (HxWxD) Outdoor (mm) | 550x675x284 | 595x845x300 | 695x930x350 | ||
| Weight Indoor (kg) | 18 | 21 | 24 | ||
| Weight Outdoor (kg) | 28 | 64 | 128 | ||
| Power Supply V/Hz | 1 Phase 220-240V, 50Hz | ||||
| Compressor Type | Hermetically Sealed Swing Type | ||||
| Refrigerant | R32 | ||||
| Pipe Sizes Liquid (mm) | 6.4 (Flared) | 6.4 (Flared) | |||
| Pipe Sizes Gas (mm) | 9.5 (Flared) | 12.7 (Flared) | |||
| Pipe Sizes Drain (mm) | ID 20 / OD 26 | ||||
| Supply Air Opening mm (HxW, Flange) | 153x660 | 153x860 | 153x1060 | ||
| Return Air Opening mm (HxW) | 163x575 | 163x775 | 163x975 | ||
| Outdoor Operating Range Cool (°CDB) | -10 to 50 | ||||
| Outdoor Operating Range Heat (°CWB) | -15 to 18 | ||||
| EPA Sound Power Level dBA | 60 | 60 | 62 | 63 | 67 |
| Outdoor Sound Level (H) @ 1m Pressure dBA (C/H) | 45/48 | 47/48 | 47/50 | 48/51 | 53/55 |
Source: Daikin Australia, Ducted Systems brochure (PDF), page 16. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Daikin Premium Inverter Ducted Underfloor
Daikin's underfloor ducted solution, which Daikin describes as ideal for homes in colder climates where heating is a focus, with units installed under the floor to promote even warm air distribution.
- System: Reverse Cycle
- Capacities: 7.1kW, 12.5kW, 16.0kW
- Indoor Type: Ducted
- Power Supply: 1 Phase, 220-240V, 50Hz
- Refrigerant: R32
- Controllers listed: Daikin AirHub and Daikin Airbase
Official Daikin Ducted Systems brochure (PDF) | Official range page
Daikin's Ducted Systems brochure does not include a separate underfloor specification table, so only the summary published on the official range page is shown.
Daikin Inverter Ducted Underfloor
An underfloor version of the Inverter ducted series, available in single phase and three phase.
- System: Reverse Cycle
- Capacities: Single Phase: 7.1kW, 12.5kW, 15.5kW, Three Phase: 7.1kW, 12.5kW, 15.5kW
- Indoor Type: Ducted
- Power Supply: 1 Phase, 220-240V, 50Hz, 3 Phase, 380-415V, 50Hz
- Refrigerant: R32
- Controllers listed: Daikin AirHub and Daikin Airbase
Official Daikin Ducted Systems brochure (PDF) | Official range page
Daikin's Ducted Systems brochure does not include a separate underfloor specification table, so only the technical summary published on the official range page is shown.
How we install a Daikin ducted system in Melbourne
- Enquiry and assessment. We discuss the rooms you want to heat and cool, then assess the home, including room sizes, insulation, windows and orientation, and where the indoor and outdoor units can go.
- Recommendation and written quote. We recommend a Daikin ducted range and capacity that suits the home and explain the options before you commit.
- Installation. Our team installs the indoor and outdoor units, runs the refrigerant pipework and condensate drain, and completes the electrical connection as required by Victorian regulations.
- Commissioning and handover. We test heating and cooling operation, set up the controller and show you how to use the system and look after the filters.
- Ongoing service. Regular maintenance keeps the system running efficiently. See our maintenance services.
Manufacturer warranty
Daikin Australia states that "Daikin's 5-year parts and labour warranty applies to split, multi split and ducted air conditioners purchased and installed in homes across Australia" (Daikin Australia). Warranty periods, coverage, conditions and exclusions are set out in the Daikin Manufacturer's Warranty Card on the Daikin warranty page.
Victorian Energy Upgrades
EZYAIR is a Victorian Energy Upgrades (VEU) accredited provider (accreditation A2261). If you are replacing an older heater with an efficient reverse cycle system, ask us whether your project may be eligible for a VEU discount. Eligibility depends on the existing heater, the new product and the program rules at the time. Learn more on our Victorian Energy Upgrades page.
You can see a range of wall hung, cassette, ducted, bulkhead and floor console units on display, many of them operational, at our Burwood showroom at 49 Huntingdale Rd, Burwood VIC 3125.
Related pages
- Daikin air conditioning in Melbourne (overview)
- Daikin split systems
- Daikin multi split systems
- Ducted reverse cycle air conditioning in Melbourne
- Ducted heating in Melbourne
- Bulkhead air conditioner installation
- Ducted air conditioning maintenance
Daikin ducted air conditioning FAQs
Which Daikin ducted series suits a Melbourne home?
Premium Inverter suits homes wanting the highest efficiency, and Daikin offers Heating Focus models for cold climates such as Melbourne. Inverter suits typical family homes with tighter roof space, Slimline suits narrow ceilings and apartments, and the underfloor ranges suit homes where floor outlets are preferred. We assess your home before recommending a series.
Can a Daikin ducted system be zoned?
Yes. Daikin lists the Daikin Airbase controller with 4 or 8 zone designs for the Premium Inverter and Inverter ranges, and a zone controller for Slimline. Zoning lets you heat or cool selected areas only.
Can I keep my existing pipework when upgrading an old R22 ducted system?
Daikin lists R22 retrofit capability for several ducted series, retaining the field piping. It is not available for 18.0 kW, 20.0 kW and Heating Focus models. We inspect the existing system to confirm whether this is suitable.
What warranty applies to Daikin ducted air conditioning?
Daikin Australia states that its 5-year parts and labour warranty applies to split, multi split and ducted air conditioners purchased and installed in homes across Australia. Full conditions are in the Daikin Manufacturer's Warranty Card.
Can EZYAIR replace my gas ducted heating with a Daikin ducted system?
Yes. We replace older ducted heating with reverse cycle ducted systems. As a VEU accredited provider (A2261) we can check whether your project may be eligible for a Victorian Energy Upgrades discount.
Request a quote
Planning Daikin ducted air conditioning for your Melbourne home? Contact EZYAIR or call 1300 EZYAIR (1300 399 247).