Daikin Multi Split Systems Melbourne
A Daikin multi split system connects several indoor units to one outdoor unit, so you can heat and cool multiple rooms with independent control in each. EZYAIR designs and installs Daikin multi split systems across Melbourne, from two bedroom apartments to large homes.
Who a Daikin multi split suits
Multi split systems suit Melbourne apartments, townhouses and homes with limited outdoor space, and homes that want to add rooms later within the capacity of the outdoor unit. For a single room, a Daikin split system is simpler. For whole home comfort through ducts, see Daikin ducted air conditioning.
Current Daikin multi split ranges
The following ranges are listed on Daikin Australia's residential multi split page at the time of writing (October 2026).
EZYAIR is an independent air conditioning installer. Product information on this page is copied from Daikin Australia's official website and brochures. Figures are as published by the manufacturer. Where a figure is not published it is not shown. Tables scroll sideways on smaller screens.
Daikin Super Multi NX
Daikin's residential multi split system, using one outdoor unit to maintain comfort in up to five rooms. Indoor unit options include wall mounted, bulkhead, ducted and cassette types, each controlled individually.
- Capacities listed on the official page: Reverse Cycle: 5.2kW, 6.8kW, 8.0kW, 10.0kW; Cooling Only: 5.2kW, 6.8kW, 8.0kW, 10.0kW. Refrigerant: R32
- Features listed by Daikin: 2-Area Intelligent Eye, Heat Plus (wall mounted units), Priority Room Comfort and up to 5 indoor units per outdoor unit
Official Daikin Super Multi NX brochure (PDF) | Official range page
Note: the technical summary box on Daikin's Super Multi NX web page repeats the wall mounted split capacities. The outdoor unit capacities above are taken from the main section of the same page, and the tables are copied from the Super Multi NX brochure linked from that page.
Specifications: Outdoor units, reverse cycle (4 models)
| Model name | Reverse cycle | |||
|---|---|---|---|---|
| Model name | 3MXM52RVMA | 4MXM68RVMA | 4MXM80RVMA | 5MXM100RVMA |
| Power supply | 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz | |||
| Max. connected indoor units capacity kW | 9.0 | 11.0 | 14.5 | 15.6 |
| Casing colour | Ivory white | |||
| Compressor type | Hermetically sealed swing type | |||
| Refrigerant type | R-32 | |||
| Outdoor sound pressure level*1 Rated/ Quiet Cooling | 45/43 | 47/44 | 48/45 | 48/46 |
| Outdoor sound pressure level*1 Heating dB(A) | 47/45 | 48/46 | 49/47 | |
| Outdoor sound power level H Cooling | 57 | 59 | 60 | |
| Outdoor sound power level Heating dB(A) | 59 | 60 | 61 | |
| Dimensions H x W x D mm | 695 x 930 x 350 | 990 x 940 x 320 | ||
| Machine weight kg | 53 | 56 | 61 | 83 |
| Outdoor operating range Cooling ˚CDB | -10 to 46 | |||
| Outdoor operating range Heating ˚CWB | -15 to 18 | |||
| Max. piping length m | 50 (total) | 60 (total) | 70 (total) | 80 (total) |
| Max. piping length | 30 (for one room) | |||
| Additional charge g/m | 20 (for over 40 m) | |||
| Max. level difference m | 15 (between indoor and outdoor units) / 7.5 (between indoor units) | |||
Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Outdoor units, cooling only (4 models)
| Model name | Cooling only | |||
|---|---|---|---|---|
| Model name | 3MKM52RVMA | 4MKM68RVMA | 4MKM80RVMA | 5MKM100RVMA |
| Power supply | 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz | |||
| Max. connected indoor units capacity kW | 9.0 | 11.0 | 14.5 | 15.6 |
| Casing colour | Ivory white | |||
| Compressor type | Hermetically sealed swing type | |||
| Refrigerant type | R-32 | |||
| Outdoor sound pressure level*1 Rated/Quiet dB(A) | 45/43 | 47/44 | 48/45 | 48/46 |
| Outdoor sound power level H dB(A) | 57 | 59 | 60 | |
| Dimensions H x W x D mm | 695 x 930 x 350 | 990 x 940 x 320 | ||
| Machine weight kg | 49 | 52 | 79 | |
| Outdoor operating range ˚CDB | 10 to 46 | |||
| Max. piping length m | 50 (total) | 60 (total) | 70 (total) | 80 (total) |
| Max. piping length | 30 (for one room) | |||
| Additional charge g/m | Chargeless | |||
| Max. level difference m | 15 (between indoor and outdoor units) / 7.5 (between indoor units) | |||
Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Wall mounted indoor units CTXM (50 to 95 class), reverse cycle (5 models)
| Reverse cycle | |||||
|---|---|---|---|---|---|
| Model name | CTXM50RVMA | CTXM60RVMA | CTXM71RVMA | CTXM85RVMA | CTXM95RVMA |
| Power supply | 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz | ||||
| Front panel colour | White | ||||
| Indoor airflow rate H Cooling l/s | 282 (597) | 325 (689) | 333 (706) | 398 (844) | 400 (848) |
| Indoor airflow rate Heating (cfm) | 287 (607) | 333 (706) | 328 (696) | 422 (893) | 413 (876) |
| Indoor sound pressure level H/L/SL Cooling | 45/35/28 | 48/36/29 | 49/37/30 | 51/40/37 | 53/42/38 |
| Indoor sound pressure level Heating dB(A) | 45/33/28 | 48/33/29 | 49/35/30 | 51/38/35 | 52/38/35 |
| Indoor sound power level H Cooling | 59 | 62 | 63 | 65 | 67 |
| Indoor sound power level Heating dB(A) | 59 | 62 | 63 | 65 | 66 |
| Fan speed | 5 steps, quiet and automatic | ||||
| Temperature control | Microcomputer control | ||||
| Dimensions H x W x D mm | 295 x 990 x 263 | 340 x 1,200 x 259 | |||
| Machine weight kg | 13 | 17 | 18 | ||
| Piping connections Liquid (flare) mm | ø6.4 | ||||
| Piping connections Gas (flare) | ø12.7 | ø15.9 | |||
| Piping connections Drain | ø16.0 | ||||
| Heat insulation | Both liquid and gas pipes | ||||
Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Wall mounted indoor units CTXM (20 to 46 class), reverse cycle (4 models)
| Reverse cycle | ||||
|---|---|---|---|---|
| Model name | CTXM20RVMA | CTXM25RVMA | CTXM35RVMA | CTXM46RVMA |
| Power supply | 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz | |||
| Front panel colour | White | |||
| Indoor airflow rate H Cooling l/s | 155 (328) | 173 (367) | 188 (399) | 203 (431) |
| Indoor airflow rate Heating (cfm) | 160 (339) | 173 (367) | 188 (399) | 202 (427) |
| Indoor sound pressure level H/L/SL Cooling dB(A) | 38/25/19 | 40/25/19 | 42/26/19 | 44/35/26 |
| Indoor sound pressure level Heating | 39/28/20 | 40/28/20 | 42/29/20 | 43/33/26 |
| Indoor sound power level H Cooling dB(A) | 52 | 54 | 56 | 58 |
| Indoor sound power level Heating | 53 | 54 | 56 | 57 |
| Fan speed | 5 steps, quiet and automatic | |||
| Temperature control | Microcomputer control | |||
| Dimensions H x W x D mm | 285 x 770 x 223 | |||
| Machine weight kg | 9 | |||
| Piping connections Liquid (flare) mm | ø6.4 | |||
| Piping connections Gas (flare) | ø9.5 | ø12.7 | ||
| Piping connections Drain | ø16.0 | |||
| Heat insulation | Both liquid and gas pipes | |||
Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Wall mounted indoor units CTKM, cooling only (7 models)
| Cooling only | |||||||
|---|---|---|---|---|---|---|---|
| Model name | CTKM20RVMA | CTKM25RVMA | CTKM35RVMA | CTKM46RVMA | CTKM50RVMA | CTKM60RVMA | CTKM71RVMA |
| Power supply | 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz | ||||||
| Front panel colour | White | ||||||
| Indoor airflow rate H l/s (cfm) | 160 (339) | 178 (378) | 195 (413) | 203 (431) | 282 (597) | 325 (689) | 333 (706) |
| Indoor sound pressure level H/L/SL dB(A) | 38/25/19 | 40/25/19 | 42/26/19 | 44/35/26 | 45/35/28 | 48/36/29 | 49/37/30 |
| Indoor sound power level H dB(A) | 52 | 54 | 56 | 58 | 59 | 62 | 63 |
| Fan speed | 5 steps, quiet and automatic | ||||||
| Temperature control | Microcomputer control | ||||||
| Dimensions H x W x D mm | 285 x 770 x 223 | 295 x 990 x 263 | |||||
| Machine weight kg | 8 | 9 | 13 | ||||
| Piping connections Liquid (flare) mm | ø6.4 | ||||||
| Piping connections Gas (flare) | ø9.5 | ø12.7 | ø15.9 | ||||
| Piping connections Drain | ø16.0 | ||||||
| Heat insulation | Both liquid and gas pipes | ||||||
Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Wall mounted indoor units CTXJ, White hairline (4 models)
| Reverse cycle | ||||
|---|---|---|---|---|
| Model name | CTXJ25TVMAW | CTXJ35TVMAW | CTXJ50TVMAW | CTXJ60TVMAW |
| Power supply | 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz | |||
| Front panel colour | White hairline | |||
| Indoor airflow rate H Cooling | 177 (374) | 190 (403) | 218 (463) | 243 (516) |
| Indoor airflow rate Heating l/s (cfm) | 203 (431) | 212 (448) | 238 (505) | 273 (579) |
| Indoor sound pressure level H/L/SL Cooling | 40/25/19 | 42/26/20 | 45/35/32 | 48/36/33 |
| Indoor sound pressure level Heating dB(A) | 41/28/19 | 42/29/20 | 45/35/32 | 48/37/33 |
| Indoor sound power level H Cooling | 56 | 58 | 61 | 64 |
| Indoor sound power level Heating dB(A) | 57 | 58 | 61 | 64 |
| Fan speed | 5 steps, quiet and automatic | |||
| Temperature control | Microcomputer control | |||
| Dimensions H x W x D mm | 295×798×185 | |||
| Machine weight kg | 11 | |||
| Piping connections Liquid (flare) mm | ø6.4 | |||
| Piping connections Gas (flare) | ø9.5 | ø12.7 | ||
| Piping connections Drain | ø16.0 | |||
| Heat insulation | Both liquid and gas pipes | |||
Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Wall mounted indoor units CTXJ, Black wood (4 models)
| Reverse cycle | ||||
|---|---|---|---|---|
| Model name | CTXJ25TVMAK | CTXJ35TVMAK | CTXJ50TVMAK | CTXJ60TVMAK |
| Power supply | 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz | |||
| Front panel colour | Black wood | |||
| Indoor airflow rate H Cooling | 177 (374) | 190 (403) | 218 (463) | 243 (516) |
| Indoor airflow rate Heating l/s (cfm) | 203 (431) | 212 (448) | 238 (505) | 273 (579) |
| Indoor sound pressure level H/L/SL Cooling dB(A) | 40/25/19 | 42/26/20 | 45/35/32 | 48/36/33 |
| Indoor sound pressure level Heating | 41/28/19 | 42/29/20 | 45/35/32 | 48/37/33 |
| Indoor sound power level H Cooling dB(A) | 56 | 58 | 61 | 64 |
| Indoor sound power level Heating | 57 | 58 | 61 | 64 |
| Fan speed | 5 steps, quiet and automatic | |||
| Temperature control | Microcomputer control | |||
| Dimensions H x W x D mm | 295×798×185 | |||
| Machine weight kg | 11 | |||
| Piping connections Liquid (flare) mm | ø6.4 | |||
| Piping connections Gas (flare) | ø9.5 | ø12.7 | ||
| Piping connections Drain | ø16.0 | |||
| Heat insulation | Both liquid and gas pipes | |||
Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Duct connected indoor units CDXP and CDXM, reverse cycle (7 models)
| Reverse cycle | |||||||
|---|---|---|---|---|---|---|---|
| Model name | CDXP25RVMA | CDXP35RVMA | CDXM25RVMA | CDXM35RVMA | CDXM50RVMA | CDXM60RVMA | CDXM71RVMA |
| Power supply | 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz | ||||||
| Indoor airflow rate H Cooling l/s | 145 (307) | 158 (335) | 167 (353) | 200 (424) | 267 (565) | ||
| Indoor airflow rate Heating (cfm) | 145 (307) | 158 (335) | 167 (353) | 200 (424) | 267 (565) | ||
| Indoor sound pressure level*1 H/L/SL Cooling | 35/31/29 | 37/33/31 | 38/34/32 | ||||
| Indoor sound pressure level*1 Heating dB(A) | 35/31/29 | 37/33/31 | 38/34/32 | ||||
| Indoor sound power level H Cooling dB(A) | 49 | 51 | 52 | ||||
| Indoor sound power level Heating | 49 | 51 | 52 | ||||
| Fan speed | 5 steps, quiet and automatic | ||||||
| Temperature control | Microcomputer control | ||||||
| Dimensions H x W x D mm | 200 x 700 x 620 | 200 x 900 x 620 | 200 x 1,100 x 620 | ||||
| Machine weight kg | 21 | 25 | 27 | 30 | |||
| Piping connections Liquid (flare) mm | ø6.4 | ||||||
| Piping connections Gas (flare) | ø9.5 | ø12.7 | ø15.9 | ||||
| Piping connections Drain | VP 20 (Inside diameter ø20, Outside diameter ø26) | ||||||
| Heat insulation | Both liquid and gas pipes | ||||||
Source: Daikin Australia, Super Multi NX brochure (PDF), page 20. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Duct connected indoor units CDXP and CDXM, cooling only (7 models)
| Cooling only | |||||||
|---|---|---|---|---|---|---|---|
| Model name | CDXP25RVMA | CDXP35RVMA | CDXM25RVMA | CDXM35RVMA | CDXM50RVMA | CDXM60RVMA | CDXM71RVMA |
| Power supply | 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz | ||||||
| Indoor airflow rate H l/s (cfm) | 145 (307) | 158 (335) | 167 (353) | 200 (424) | 267 (565) | ||
| Indoor sound pressure level*1 H/L/SL dB(A) | 35/31/29 | 37/33/31 | 38/34/32 | ||||
| Indoor sound power level H dB(A) | 49 | 51 | 52 | ||||
| Fan speed | 5 steps, quiet and automatic | ||||||
| Temperature control | Microcomputer control | ||||||
| Dimensions H x W x D mm | 200 x 700 x 620 | 200 x 900 x 620 | 200 x 1,100 x 620 | ||||
| Machine weight kg | 21 | 25 | 27 | 30 | |||
| Piping connections Liquid (flare) mm | ø6.4 | ||||||
| Piping connections Gas (flare) | ø9.5 | ø12.7 | ø15.9 | ||||
| Piping connections Drain | VP 20 (Inside diameter ø20, Outside diameter ø26) | ||||||
| Heat insulation | Both liquid and gas pipes | ||||||
Source: Daikin Australia, Super Multi NX brochure (PDF), page 20. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Duct connected indoor units FMA (6 models)
| Model name | Cooling only | Reverse cycle | ||||
|---|---|---|---|---|---|---|
| Model name | FMA50RVMA | FMA60RVMA | FMA71RVMA | FMA50RVMA | FMA60RVMA | FMA71RVMA |
| Power supply | 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz | |||||
| Indoor airflow rate H Cooling l/s | 300 | 383 | 300 | 383 | ||
| Indoor airflow rate Heating | - | 300 | 383 | |||
| Indoor sound pressure level H/L Cooling dB(A) | 35/31 | 38/33 | 35/31 | 38/33 | ||
| Indoor sound pressure level Heating | - | 35/31 | 38/33 | |||
| Indoor sound power level H Cooling dB(A) | 49 | 52 | 49 | 52 | ||
| Indoor sound power level Heating | - | 49 | 52 | |||
| Fan speed | 3 steps | |||||
| Temperature control | - | |||||
| Dimensions H x W x D mm | 245 x 1,000 x 800 | |||||
| Machine weight kg | 37 | |||||
| Piping connections Liquid (flare) mm | ø6.4 | |||||
| Piping connections Gas (flare) | ø12.7 | ø15.9 | ø12.7 | ø15.9 | ||
| Piping connections Drain | VP 25 (Inside diameter ø25, Outside diameter ø32) | |||||
| Heat insulation | - | |||||
Source: Daikin Australia, Super Multi NX brochure (PDF), page 20. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: Ceiling mounted cassette indoor units FFA (8 models)
| Model name | Cooling only | Reverse cycle | ||||||
|---|---|---|---|---|---|---|---|---|
| Model name | FFA25RV1A | FFA35RV1A | FFA50RV1A | FFA60RV1A | FFA25RV1A | FFA35RV1A | FFA50RV1A | FFA60RV1A |
| Power supply | 1 phase, 220-240 V, 50 Hz | |||||||
| Indoor airflow rate H Cooling l/s | 150 (318) | 167 (353) | 200 (424) | 250 (530) | 150 (318) | 167 (353) | 200 (424) | 250 (530) |
| Indoor airflow rate Heating (cfm) | - | 150 (318) | 167 (353) | 200 (424) | 250 (530) | |||
| Indoor sound pressure level H/L Cooling | 33/27 | 36/29 | 38/30 | 42/34 | 33/27 | 36/29 | 38/30 | 42/34 |
| Indoor sound pressure level Heating dB(A) | - | 33/27 | 36/28 | 38/28 | 42/34 | |||
| Indoor sound power level H Cooling | 46 | 49 | 51 | 55 | 46 | 49 | 51 | 55 |
| Indoor sound power level Heating dB(A) | - | 46 | 49 | 51 | 55 | |||
| Fan speed | 2 steps | |||||||
| Temperature control | Microcomputer control | |||||||
| dimensions H x W x D mm | 286 x 575 x 575 | |||||||
| Machine weight kg | 17.5 | |||||||
| Piping connections Liquid (flare) mm | ø6.4 | |||||||
| Piping connections Gas (flare) | ø9.5 | ø12.7 | ø9.5 | ø12.7 | ||||
| Piping connections Drain | VP 20 (Inside diameter ø20, Outside diameter ø26) | |||||||
| Heat insulation | Both liquid and gas pipes | |||||||
Source: Daikin Australia, Super Multi NX brochure (PDF), page 20. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Daikin VRV IV-S
A residential VRV system that Daikin describes as bringing technology from its commercial VRV range to the home, with up to 14 indoor units (bulkhead and ducted types) on one compact outdoor unit and pipe runs of up to 100 m (24 kW model).
- Capacities listed on the official page: 9.0kW, 11.2kW, 14.0kW, 16.0kW, 22.4kW, 24.0kW. Refrigerant: R410A
- Controllers listed: residential wall controller
Official Daikin VRV brochure (PDF) | Official range page
Specifications: VRV IV-S outdoor units (6 models)
| MODEL | RXYMQ3A2V4A | RXYMQ4A2V4A | RXYMQ5B2VM | RXYMQ6B2VM | RXYMQ8AY1 | RXYMQ9AY1 |
|---|---|---|---|---|---|---|
| Power supply | 1-phase, 220-230 V, 50 Hz | 1-phase, 220-240 V/220-230 V, 50/60 Hz | 3-phase, 380-415 V, 50 Hz | |||
| Cooling capacity Btu/h | 30,700 | 38,200 | 47,800 | 54,600 | 76,400 | 81,900 |
| Cooling capacity kW | 9.0 | 11.2 | 14.0 | 16.0 | 22.4 | 24.0 |
| Heating capacity Btu/h | 34,100 | 42,700 | 47,800 | 54,600 | 85,300 | 88,700 |
| Heating capacity kW | 10.0 | 12.5 | 14.0 | 16.0 | 25.0 | 26.0 |
| Power consumption Cooling kW | 2.44 | 2.88 | 3.83 | 4.51 | 5.94 | 6.88 |
| Power consumption Heating | 2.28 | 2.60 | 3.04 | 3.59 | 6.25 | 6.82 |
| Capacity control % | 24 to 100 | 15 to 100 | 20 to 100 | |||
| AEER★ Cooling | - | - | 3.39 | 3.31 | - | - |
| ACOP★ Heating | - | - | 4.20 | 4.09 | - | - |
| TCSPF★ (Cooling) Commercial / Residential Hot | - | - | 5.38 / 4.87 | 5.16 / 4.70 | - | - |
| TCSPF★ (Cooling) Commercial / Residential Average | - | - | 5.29 / 4.02 | 5.11 / 3.97 | - | - |
| TCSPF★ (Cooling) Commercial / Residential Cold | - | - | 5.58 / 4.01 | 5.40 / 3.99 | - | - |
| HSPF★ (Heating) Commercial / Residential Hot | - | - | 4.33 / 4.35 | 4.28 / 4.30 | - | - |
| HSPF★ (Heating) Commercial / Residential Average | - | - | 4.20 / 4.16 | 4.14 / 4.08 | - | - |
| HSPF★ (Heating) Commercial / Residential Cold | - | - | 3.91 / 3.80 | 3.84 / 3.71 | - | - |
| Casing colour | Ivory white (5Y7.5/1) | |||||
| Compressor Type | Hermetically sealed swing type | Hermetically sealed scroll type | ||||
| Compressor Motor output (Cooling/Heating) kW | 1.92 | 3.2/3.5 | 3.7 | 3.8 | 4.8 | |
| Airflow rate l/s | 1,267 | 1,350 | 1,333 | 2,333 | ||
| Airflow rate m3/min | 76 | 81 | 80 | 140 | ||
| Dimensions (H×W×D) mm | 990×940×320 | 1,430×940×320 | ||||
| Machine weight kg | 71 | 78 | 80 | 138 | ||
| Sound level (Cooling/Heating) dB(A) | 51/52 | 52/54 | 53/54 | 55/56 | 57/58 | 58/59 |
| Sound power dB(A) | 69 | 70 | 74 | 76 | 75 | 76 |
| Operation range Cooling °CDB | -5 to 46 | |||||
| Operation range Heating °CWB | -20 to 15.5 | |||||
| Refrigerant Type | R-410A | |||||
| Refrigerant Charge kg | 2.9 | 3.4 | 4.0 | 5.8 | ||
| Piping connections Liquid mm | 9.5 (Flare) | 9.5 (Brazing) | ||||
| Piping connections Gas | 15.9 (Flare) | 19.1 (Brazing) | 22.2 (Brazing) | |||
Source: Daikin Australia, VRV brochure (PDF), page 39. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Specifications: VRV IV-S connectable indoor units (6 models)
| MODEL | RXYMQ3A2V4A | RXYMQ4A2V4A | RXYMQ5B2VM | RXYMQ6B2VM | RXYMQ8AY1 | RXYMQ9AY1 |
|---|---|---|---|---|---|---|
| kW | 9.0 | 11.2 | 14.0 | 16.0 | 22.4 | 24.0 |
| class | 3.5 | 4 | 5 | 6 | 8 | 9 |
| Capacity index | 80 | 100 | 125 | 150 | 200 | 215 |
| Total capacity index of connectable indoor units Combination (%) 50% | 40 | 50 | 62.5 | 75 | 100 | 107.5 |
| Total capacity index of connectable indoor units 100% | 80 | 100 | 125 | 150 | 200 | 215 |
| Total capacity index of connectable indoor units 130% | 104 | 130 | 162.5 | 195 | 260 | 280 |
| Maximum number of connectable indoor units | 5 | 6 | 8 | 9 | 13 | 14 |
Source: Daikin Australia, VRV brochure (PDF), page 39. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
How we install a Daikin multi split system in Melbourne
- Enquiry and assessment. We discuss the rooms you want to heat and cool, then assess the home, including room sizes, insulation, windows and orientation, and where the indoor and outdoor units can go.
- Recommendation and written quote. We recommend a Daikin multi split range and capacity that suits the home and explain the options before you commit.
- Installation. Our team installs the indoor and outdoor units, runs the refrigerant pipework and condensate drain, and completes the electrical connection as required by Victorian regulations.
- Commissioning and handover. We test heating and cooling operation, set up the controller and show you how to use the system and look after the filters.
- Ongoing service. Regular maintenance keeps the system running efficiently. See our maintenance services.
Manufacturer warranty
Daikin Australia states that "Daikin's 5-year parts and labour warranty applies to split, multi split and ducted air conditioners purchased and installed in homes across Australia" (Daikin Australia). Warranty periods, coverage, conditions and exclusions are set out in the Daikin Manufacturer's Warranty Card on the Daikin warranty page.
Victorian Energy Upgrades
EZYAIR is a Victorian Energy Upgrades (VEU) accredited provider (accreditation A2261). If you are replacing an older heater with an efficient reverse cycle system, ask us whether your project may be eligible for a VEU discount. Eligibility depends on the existing heater, the new product and the program rules at the time. Learn more on our Victorian Energy Upgrades page.
You can see a range of wall hung, cassette, ducted, bulkhead and floor console units on display, many of them operational, at our Burwood showroom at 49 Huntingdale Rd, Burwood VIC 3125.
Related pages
- Daikin air conditioning in Melbourne (overview)
- Daikin ducted air conditioning
- Daikin split systems
- Multi split air conditioning in Melbourne
- Apartment air conditioning
- Townhouse air conditioning
- Multi split service and maintenance
Daikin multi split system FAQs
How many rooms can a Daikin multi split system serve?
Daikin states that Super Multi NX can serve up to five rooms from one outdoor unit, and VRV IV-S can connect as many as 14 indoor units. The exact number depends on the outdoor unit and the indoor units selected.
Can I mix wall mounted and ducted units on a Daikin multi split?
Yes. Daikin lists wall mounted, bulkhead, ducted and cassette indoor units for Super Multi NX, and bulkhead and ducted indoor units for VRV IV-S. We confirm compatible combinations when we design the system.
Is a multi split suitable for a Melbourne apartment?
Often, yes. Daikin notes that multi split systems suit apartments, townhouses and houses with limited outdoor space, because one outdoor unit serves several rooms. Body corporate approval may be needed for the outdoor unit location.
What warranty applies to Daikin multi split systems?
Daikin Australia states that its 5-year parts and labour warranty applies to split, multi split and ducted air conditioners purchased and installed in homes across Australia. Full conditions are in the Daikin Manufacturer's Warranty Card.
Request a quote
Want to heat and cool several rooms with one Daikin outdoor unit? Contact EZYAIR or call 1300 EZYAIR (1300 399 247).