Daikin Multi Split Systems Melbourne

A Daikin multi split system connects several indoor units to one outdoor unit, so you can heat and cool multiple rooms with independent control in each. EZYAIR designs and installs Daikin multi split systems across Melbourne, from two bedroom apartments to large homes.

Who a Daikin multi split suits

Multi split systems suit Melbourne apartments, townhouses and homes with limited outdoor space, and homes that want to add rooms later within the capacity of the outdoor unit. For a single room, a Daikin split system is simpler. For whole home comfort through ducts, see Daikin ducted air conditioning.

Current Daikin multi split ranges

The following multi split range is listed on Daikin Australia's residential multi split page at the time of writing (October 2026).

EZYAIR is an independent air conditioning installer. Product information on this page is copied from Daikin Australia's official website and brochures. Figures are as published by the manufacturer. Where a figure is not published it is not shown. Tables scroll sideways on smaller screens.

Daikin Super Multi NX

Daikin's residential multi split system, using one outdoor unit to maintain comfort in up to five rooms. Indoor unit options include wall mounted, bulkhead, ducted and cassette types, each controlled individually.

Key facts

  • Reverse cycle capacities listed on the official page: 5.2kW, 6.8kW, 8.0kW, 10.0kW
  • Refrigerant: R32

Features listed by Daikin

  • 2-Area Intelligent Eye
  • Heat Plus (wall mounted units)
  • Priority Room Comfort
  • Up to 5 indoor units per outdoor unit

Official Daikin Super Multi NX brochure (PDF) | Official range page

Note: the technical summary box on Daikin's Super Multi NX web page repeats the wall mounted split capacities. The outdoor unit capacities above are taken from the main section of the same page, and the tables are copied from the Super Multi NX brochure linked from that page.

Specifications: Outdoor units, reverse cycle (4 models)
Outdoor units, reverse cycle
Model name Reverse cycle
Model name 3MXM52RVMA 4MXM68RVMA 4MXM80RVMA 5MXM100RVMA
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Max. connected indoor units capacity kW 9.0 11.0 14.5 15.6
Casing colour Ivory white
Compressor type Hermetically sealed swing type
Refrigerant type R-32
Outdoor sound pressure level*1 Rated/ Quiet Cooling 45/43 47/44 48/45 48/46
Outdoor sound pressure level*1 Heating dB(A) 47/45 48/46 49/47
Outdoor sound power level H Cooling 57 59 60
Outdoor sound power level Heating dB(A) 59 60 61
Dimensions H x W x D mm 695 x 930 x 350 990 x 940 x 320
Machine weight kg 53 56 61 83
Outdoor operating range Cooling ˚CDB -10 to 46
Outdoor operating range Heating ˚CWB -15 to 18
Max. piping length m 50 (total) 60 (total) 70 (total) 80 (total)
Max. piping length 30 (for one room)
Additional charge g/m 20 (for over 40 m)
Max. level difference m 15 (between indoor and outdoor units) / 7.5 (between indoor units)

Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Specifications: Wall mounted indoor units CTXM (50 to 95 class), reverse cycle (5 models)
Wall mounted indoor units CTXM (50 to 95 class), reverse cycle
Reverse cycle
Model name CTXM50RVMA CTXM60RVMA CTXM71RVMA CTXM85RVMA CTXM95RVMA
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Front panel colour White
Indoor airflow rate H Cooling l/s 282 (597) 325 (689) 333 (706) 398 (844) 400 (848)
Indoor airflow rate Heating (cfm) 287 (607) 333 (706) 328 (696) 422 (893) 413 (876)
Indoor sound pressure level H/L/SL Cooling 45/35/28 48/36/29 49/37/30 51/40/37 53/42/38
Indoor sound pressure level Heating dB(A) 45/33/28 48/33/29 49/35/30 51/38/35 52/38/35
Indoor sound power level H Cooling 59 62 63 65 67
Indoor sound power level Heating dB(A) 59 62 63 65 66
Fan speed 5 steps, quiet and automatic
Temperature control Microcomputer control
Dimensions H x W x D mm 295 x 990 x 263 340 x 1,200 x 259
Machine weight kg 13 17 18
Piping connections Liquid (flare) mm ø6.4
Piping connections Gas (flare) ø12.7 ø15.9
Piping connections Drain ø16.0
Heat insulation Both liquid and gas pipes

Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Specifications: Wall mounted indoor units CTXM (20 to 46 class), reverse cycle (4 models)
Wall mounted indoor units CTXM (20 to 46 class), reverse cycle
Reverse cycle
Model name CTXM20RVMA CTXM25RVMA CTXM35RVMA CTXM46RVMA
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Front panel colour White
Indoor airflow rate H Cooling l/s 155 (328) 173 (367) 188 (399) 203 (431)
Indoor airflow rate Heating (cfm) 160 (339) 173 (367) 188 (399) 202 (427)
Indoor sound pressure level H/L/SL Cooling dB(A) 38/25/19 40/25/19 42/26/19 44/35/26
Indoor sound pressure level Heating 39/28/20 40/28/20 42/29/20 43/33/26
Indoor sound power level H Cooling dB(A) 52 54 56 58
Indoor sound power level Heating 53 54 56 57
Fan speed 5 steps, quiet and automatic
Temperature control Microcomputer control
Dimensions H x W x D mm 285 x 770 x 223
Machine weight kg 9
Piping connections Liquid (flare) mm ø6.4
Piping connections Gas (flare) ø9.5 ø12.7
Piping connections Drain ø16.0
Heat insulation Both liquid and gas pipes

Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Specifications: Wall mounted indoor units CTXJ, White hairline (4 models)
Wall mounted indoor units CTXJ, White hairline
Reverse cycle
Model name CTXJ25TVMAW CTXJ35TVMAW CTXJ50TVMAW CTXJ60TVMAW
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Front panel colour White hairline
Indoor airflow rate H Cooling 177 (374) 190 (403) 218 (463) 243 (516)
Indoor airflow rate Heating l/s (cfm) 203 (431) 212 (448) 238 (505) 273 (579)
Indoor sound pressure level H/L/SL Cooling 40/25/19 42/26/20 45/35/32 48/36/33
Indoor sound pressure level Heating dB(A) 41/28/19 42/29/20 45/35/32 48/37/33
Indoor sound power level H Cooling 56 58 61 64
Indoor sound power level Heating dB(A) 57 58 61 64
Fan speed 5 steps, quiet and automatic
Temperature control Microcomputer control
Dimensions H x W x D mm 295×798×185
Machine weight kg 11
Piping connections Liquid (flare) mm ø6.4
Piping connections Gas (flare) ø9.5 ø12.7
Piping connections Drain ø16.0
Heat insulation Both liquid and gas pipes

Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Specifications: Wall mounted indoor units CTXJ, Black wood (4 models)
Wall mounted indoor units CTXJ, Black wood
Reverse cycle
Model name CTXJ25TVMAK CTXJ35TVMAK CTXJ50TVMAK CTXJ60TVMAK
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Front panel colour Black wood
Indoor airflow rate H Cooling 177 (374) 190 (403) 218 (463) 243 (516)
Indoor airflow rate Heating l/s (cfm) 203 (431) 212 (448) 238 (505) 273 (579)
Indoor sound pressure level H/L/SL Cooling dB(A) 40/25/19 42/26/20 45/35/32 48/36/33
Indoor sound pressure level Heating 41/28/19 42/29/20 45/35/32 48/37/33
Indoor sound power level H Cooling dB(A) 56 58 61 64
Indoor sound power level Heating 57 58 61 64
Fan speed 5 steps, quiet and automatic
Temperature control Microcomputer control
Dimensions H x W x D mm 295×798×185
Machine weight kg 11
Piping connections Liquid (flare) mm ø6.4
Piping connections Gas (flare) ø9.5 ø12.7
Piping connections Drain ø16.0
Heat insulation Both liquid and gas pipes

Source: Daikin Australia, Super Multi NX brochure (PDF), page 19. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Specifications: Duct connected indoor units CDXP and CDXM, reverse cycle (7 models)
Duct connected indoor units CDXP and CDXM, reverse cycle
Reverse cycle
Model name CDXP25RVMA CDXP35RVMA CDXM25RVMA CDXM35RVMA CDXM50RVMA CDXM60RVMA CDXM71RVMA
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Indoor airflow rate H Cooling l/s 145 (307) 158 (335) 167 (353) 200 (424) 267 (565)
Indoor airflow rate Heating (cfm) 145 (307) 158 (335) 167 (353) 200 (424) 267 (565)
Indoor sound pressure level*1 H/L/SL Cooling 35/31/29 37/33/31 38/34/32
Indoor sound pressure level*1 Heating dB(A) 35/31/29 37/33/31 38/34/32
Indoor sound power level H Cooling dB(A) 49 51 52
Indoor sound power level Heating 49 51 52
Fan speed 5 steps, quiet and automatic
Temperature control Microcomputer control
Dimensions H x W x D mm 200 x 700 x 620 200 x 900 x 620 200 x 1,100 x 620
Machine weight kg 21 25 27 30
Piping connections Liquid (flare) mm ø6.4
Piping connections Gas (flare) ø9.5 ø12.7 ø15.9
Piping connections Drain VP 20 (Inside diameter ø20, Outside diameter ø26)
Heat insulation Both liquid and gas pipes

Source: Daikin Australia, Super Multi NX brochure (PDF), page 20. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Specifications: Duct connected indoor units FMA (6 models)
Duct connected indoor units FMA
Model name Cooling only Reverse cycle
Model name FMA50RVMA FMA60RVMA FMA71RVMA FMA50RVMA FMA60RVMA FMA71RVMA
Power supply 1 phase, 220-240 V, 50 Hz / 1 phase, 220-230 V, 60 Hz
Indoor airflow rate H Cooling l/s 300 383 300 383
Indoor airflow rate Heating - 300 383
Indoor sound pressure level H/L Cooling dB(A) 35/31 38/33 35/31 38/33
Indoor sound pressure level Heating - 35/31 38/33
Indoor sound power level H Cooling dB(A) 49 52 49 52
Indoor sound power level Heating - 49 52
Fan speed 3 steps
Temperature control -
Dimensions H x W x D mm 245 x 1,000 x 800
Machine weight kg 37
Piping connections Liquid (flare) mm ø6.4
Piping connections Gas (flare) ø12.7 ø15.9 ø12.7 ø15.9
Piping connections Drain VP 25 (Inside diameter ø25, Outside diameter ø32)
Heat insulation -

Source: Daikin Australia, Super Multi NX brochure (PDF), page 20. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

How we install a Daikin multi split system in Melbourne

  1. Enquiry and assessment. We discuss the rooms you want to heat and cool, then assess the home, including room sizes, insulation, windows and orientation, and where the indoor and outdoor units can go.
  2. Recommendation and written quote. We recommend a Daikin multi split range and capacity that suits the home and explain the options before you commit.
  3. Installation. Our team installs the indoor and outdoor units, runs the refrigerant pipework and condensate drain, and completes the electrical connection as required by Victorian regulations.
  4. Commissioning and handover. We test heating and cooling operation, set up the controller and show you how to use the system and look after the filters.
  5. Ongoing service. Regular maintenance keeps the system running efficiently. See our maintenance services.

Manufacturer warranty

Daikin Australia states that "Daikin's 5-year parts and labour warranty applies to split, multi split and ducted air conditioners purchased and installed in homes across Australia" (Daikin Australia). Warranty periods, coverage, conditions and exclusions are set out in the Daikin Manufacturer's Warranty Card on the Daikin warranty page.

Victorian Energy Upgrades

EZYAIR is a Victorian Energy Upgrades (VEU) accredited provider (accreditation A2261). If you are replacing an older heater with an efficient reverse cycle system, ask us whether your project may be eligible for a VEU discount. Eligibility depends on the existing heater, the new product and the program rules at the time. Learn more on our Victorian Energy Upgrades page.

You can see a range of wall hung, ducted and bulkhead units on display, many of them operational, at our Burwood showroom at 49 Huntingdale Rd, Burwood VIC 3125.

Related pages

Daikin multi split system FAQs

How many rooms can a Daikin multi split system serve?

Daikin states that Super Multi NX can serve up to five rooms from one outdoor unit. The exact number depends on the outdoor unit and the indoor units selected.

Can I mix wall mounted and ducted units on a Daikin multi split?

Yes. Daikin lists wall mounted, bulkhead and ducted indoor units for Super Multi NX. We confirm compatible combinations when we design the system.

Is a multi split suitable for a Melbourne apartment?

Often, yes. Daikin notes that multi split systems suit apartments, townhouses and houses with limited outdoor space, because one outdoor unit serves several rooms. Body corporate approval may be needed for the outdoor unit location.

What warranty applies to Daikin multi split systems?

Daikin Australia states that its 5-year parts and labour warranty applies to split, multi split and ducted air conditioners purchased and installed in homes across Australia. Full conditions are in the Daikin Manufacturer's Warranty Card.

Request a quote

Want to heat and cool several rooms with one Daikin outdoor unit? Contact EZYAIR or call 1300 EZYAIR (1300 399 247).

You have successfully subscribed!