Panasonic Ducted Air Conditioning Melbourne

A Panasonic ducted reverse cycle system heats and cools the whole home from a concealed indoor unit in the roof or ceiling, with air delivered to each room through ducts and discreet outlets. EZYAIR designs, supplies and installs Panasonic ducted air conditioning across Melbourne on request. Request a Panasonic ducted air conditioning quote or call 1300 EZYAIR (1300 399 247).

Is Panasonic ducted air conditioning right for your home?

Ducted air conditioning suits Melbourne homes that want even, quiet comfort in every room, with only grilles visible inside. It needs space for the indoor unit and ductwork, and a location for the outdoor unit. If you only need to condition a few rooms, a Panasonic multi split system or Panasonic split system may suit better.

Current Panasonic ducted ranges

The following ducted ranges are listed on Panasonic Australia's ducted page at the time of writing (October 2026). EZYAIR supplies and installs reverse cycle ducted systems up to 25kW. Panasonic's product pages publish a line up table and indoor unit specifications for each range; brochures, specification sheets and dimension drawings are available from each official product page.

Ranges are ordered from the smallest starting capacity. Select a range to jump to its details.

EZYAIR is an independent air conditioning installer. We supply and install the Panasonic systems below on request; availability of individual models is confirmed at quote stage. Specifications on this page are copied from the specification tables on Panasonic Australia's official product pages, with links to the official product pages and, where available, Panasonic's brochures. Figures are as published by the manufacturer (dash characters in ranges are shown as hyphens). Where a figure is not published it is not shown. Tables scroll sideways on smaller screens.

Panasonic R32 Inverter Ultra Slim Ducted (UD3)

A slim ducted unit from 2.6 kW to 5.6 kW (cooling) with a height of only 200 mm, which Panasonic says suits compact ceiling spaces. It can be paired with its own outdoor unit or connected to a Panasonic multi split system.

Slim ducted units such as the UD3 can be concealed in a bulkhead or ceiling space to condition one or two rooms. See our bulkhead air conditioner installation page for how we plan and install them in Melbourne homes.

Key facts

  • Refrigerant: R32
  • Operation: Reverse Cycle (heating and cooling capacities published)
  • Indoor unit height: 200 mm (all models)
  • Connection: own outdoor unit or a Panasonic multi split system
Ultra Slim Ducted (UD3): models and rated capacities
Indoor unit Outdoor unit (single split) Cooling (kW) Heating (kW)
CS-Z25UD3RAW CU-Z25UBRA 2.6 3.3
CS-Z35UD3RAW CU-Z35UBRA 3.7 4.2
CS-Z50UD3RAW CU-Z50UBRA 5.0 6.1
CS-Z60UD3RAW CU-Z60UBRA 5.6 7.0

Cooling and heating figures are as published in the line up table on the official Panasonic product page. Where Panasonic shows two heating figures (for example 7.1/8.0) they are reproduced exactly as published. Panasonic does not publish a separate nominal size, so it is not shown.

Features listed by Panasonic

  • Ultra slim 200 mm profile on all models
  • DC fan motor greatly reduces power consumption
  • 49 Pa static pressure enables ductwork to be fitted
  • Built-in drain pump
  • Easy maintenance and service by an external electrical box
  • Low sound pressure level from 23 dB(A) (CS-Z35UD3RAW)

Official range page

Specifications: Ultra Slim Ducted (UD3) line up (4 models)
Ultra Slim Ducted (UD3) line up
Rated Capacity (kW) *in case of single connection Cooling 2.6 3.7 5.0 5.6
Rated Capacity (kW) *in case of single connection Heating 3.3 4.2 6.1 7.0
Indoor Unit CS-Z25UD3RAW CS-Z35UD3RAW CS-Z50UD3RAW CS-Z60UD3RAW
Outdoor Unit (Single Split) CU-Z25UBRA CU-Z35UBRA CU-Z50UBRA CU-Z60UBRA
Outdoor Unit (Multi Split) Multi Split Air Conditioning System

Source: Panasonic Australia, R32 Inverter Ultra Slim Ducted product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Specifications: Ultra Slim Ducted (UD3) indoor units (4 models)
Ultra Slim Ducted (UD3) indoor units
Indoor unit CS-Z25UD3RAW CS-Z35UD3RAW CS-Z50UD3RAW CS-Z60UD3RAW
Air Volume (Cooling) (H/M/L) 175 Ls 187 Ls 255 Ls 262 Ls
Air Volume (Heating) (H/M/L) 175 Ls 187 Ls 255 Ls 262 Ls
Sound Pressure Level (Cooling) (H/M/L) 33/27/24 dB (A) 33/26/23 dB (A) 39/29/26 dB (A) 41/30/27 dB (A)
Sound Pressure Level (Heating) (H/M/L) 34/27/24 dB (A) 35/27/24 dB (A) 39/30/27 dB (A) 41/32/29 dB (A)
Sound Power Level (Cooling) (H/M/L) 49/43/40 dB 49/42/39 dB 55/45/42 dB 57/46/43 dB
Sound Power Level (Heating) (H/M/L) 50/43/40 dB 51/43/40 dB 55/46/43 dB 57/48/45 dB
Dimension H200 x W750 x D640 mm H200 x W750 x D640 mm H200 x W750 x D640 mm H200 x W750 x D640 mm
Net Weight 19 kg 19 kg 19 kg 19 kg

Source: Panasonic Australia, R32 Inverter Ultra Slim Ducted product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Panasonic R32 Inverter NX Series Adaptive Ducted (PF3)

Panasonic's adaptive ducted range from 3.4 kW to 13.4 kW (cooling), with nanoe™ X Generator Mark2 and a new IoT remote controller. Panasonic notes it can be installed vertically as well as horizontally.

Key facts

  • Refrigerant: R32
  • Operation: Reverse Cycle (heating and cooling capacities published)
  • Indoor unit height: 250 mm (as published)
  • Power supply: single phase, with three phase options from 9.5 kW
  • Controllers listed: CONEX remote control (wireless remote controller provided; wired CZ-RTC5B and CZ-RTC4A also available)
NX Series Adaptive Ducted (PF3): models and rated capacities
Indoor unit Power supply Outdoor unit (Deluxe) Outdoor unit (Compact) Cooling (kW) Heating (kW)
S-3650PF3E Single phase not listed U-36PZ3R5 3.4 3.6
S-3650PF3E Single phase not listed U-50PZ3R5 4.6 5.0
S-6071PF3E Single phase not listed U-60PZ4R5 5.7 5.7
S-6071PF3E Single phase U-71PZH3R5 U-71PZ4R5 6.8 6.8/7.5
S-1014PF3E Single phase U-100PZH3R5 U-100PZ4R5 9.5 9.5/10.8
S-1014PF3E Three phase U-100PZH3R8 U-100PZ4R8 9.5 9.5/10.8
S-1014PF3E Single phase U-125PZH3R5 U-125PZ4R5 12.1 12.1/13.5
S-1014PF3E Three phase U-125PZH3R8 U-125PZ4R8 12.1 12.1/13.5
S-1014PF3E Single phase U-140PZH3R5 U-140PZ4R5 13.4 13.4/15.5
S-1014PF3E Three phase U-140PZH3R8 U-140PZ4R8 13.4 13.4/15.5

Cooling and heating figures are as published in the line up table on the official Panasonic product page. Where Panasonic shows two heating figures (for example 7.1/8.0) they are reproduced exactly as published. Panasonic does not publish a separate nominal size, so it is not shown.

Features listed by Panasonic

  • nanoe™ X air purification technology
  • Air intake from rear as standard
  • Horizontal or vertical installation
  • Up to 150 Pa external static pressure
  • Space saving 250 mm height
  • Low sound levels from 22 dB(A)
  • Panasonic Comfort Cloud app control (WLAN adaptor required)

Official range page

The line up table shows the indoor and outdoor unit combinations published by Panasonic; a dash means no outdoor unit of that type is listed for that capacity.

Specifications: NX Series Adaptive Ducted (PF3) line up (10 capacity and phase options)
NX Series Adaptive Ducted (PF3) line up
Capacity (kW) Cooling 3.4 4.6 5.7 6.8 9.5 12.1 13.4
Capacity (kW) Heating 3.6 5.0 5.7 6.8/7.5 9.5/10.8 12.1/13.5 13.4/15.5
Power supply Single phase (1P) Single phase (1P) Single phase (1P) Single phase (1P) Single phase (1P) Three phase (3P) Single phase (1P) Three phase (3P) Single phase (1P) Three phase (3P)
Adaptive Ducted S-3650PF3E S-3650PF3E S-6071PF3E S-6071PF3E S-1014PF3E S-1014PF3E S-1014PF3E
Outdoor Unit (Deluxe) - - - U-71PZH3R5 U-100PZH3R5 U-100PZH3R8 U-125PZH3R5 U-125PZH3R8 U-140PZH3R5 U-140PZH3R8
Outdoor Unit (Compact) U-36PZ3R5 U-50PZ3R5 U-60PZ4R5 U-71PZ4R5 U-100PZ4R5 U-100PZ4R8 U-125PZ4R5 U-125PZ4R8 U-140PZ4R5 U-140PZ4R8

Source: Panasonic Australia, R32 Inverter NX Series Adaptive Ducted product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Specifications: NX Series Adaptive Ducted (PF3) indoor units (3 models)
NX Series Adaptive Ducted (PF3) indoor units
Indoor unit S-3650PF3E S-6071PF3E S-1014PF3E
Dimension H250 x W800 x D730 mm H250 x W1,000 x D730 mm H250 x W1,400 x D730 mm
Net Weight 25 kg 30 kg 39 kg
Number of Fan Speeds 5 5 5
Drain Piping VP-20 mm VP-20 mm VP-20 mm
3.4 kW: Air Volume (Cooling) (H/M/L) 233/217/167 L/s - -
3.4 kW: Air Volume (Heating) (H/M/L) 233/217/167 L/s - -
3.4 kW: External Static Pressure 30 (10-150) Pa - -
3.4 kW: Sound Pressure Level (Cooling) (H/M/L) 30/27/22 dB(A) - -
3.4 kW: Sound Pressure Level (Heating) (H/M/L) 30/27/22 dB(A) - -
3.4 kW: Sound Power Level (Cooling) (H/M/L) 53/50/45 dB - -
3.4 kW: Sound Power Level (Heating) (H/M/L) 53/50/45 dB - -
4.6 kW: Air Volume (Cooling) (H/M/L) 267/250/200 L/s - -
4.6 kW: Air Volume (Heating) (H/M/L) 267/250/200 L/s - -
4.6 kW: External Static Pressure 30 (10-150) Pa - -
4.6 kW: Sound Pressure Level (Cooling) (H/M/L) 34/30/25 dB(A) - -
4.6 kW: Sound Pressure Level (Heating) (H/M/L) 34/30/25 dB(A) - -
4.6 kW: Sound Power Level (Cooling) (H/M/L) 57/53/48 dB - -
4.6 kW: Sound Power Level (Heating) (H/M/L) 57/53/48 dB - -
5.7/6.8 kW: Air Volume (Cooling) (H/M/L) - 350/317/250 L/s -
5.7/6.8 kW: Air Volume (Heating) (H/M/L) - 350/317/250 L/s -
5.7/6.8 kW: External Static Pressure - 30 (10-150) Pa -
5.7/6.8 kW: Sound Pressure Level (Cooling) (H/M/L) - 30/26/23 dB(A) -
5.7/6.8 kW: Sound Pressure Level (Heating) (H/M/L) - 30/26/23 dB(A) -
5.7/6.8 kW: Sound Power Level (Cooling) (H/M/L) - 53/49/46 dB -
5.7/6.8 kW: Sound Power Level (Heating) (H/M/L) - 53/49/46 dB -
9.5 kW: Air Volume (Cooling) (H/M/L) - - 534/434/350 L/s
9.5 kW: Air Volume (Heating) (H/M/L) - - 534/434/350 L/s
9.5 kW: External Static Pressure - - 40 (10-150) Pa
9.5 kW: Sound Pressure Level (Cooling) (H/M/L) - - 33/29/25 dB(A)
9.5 kW: Sound Pressure Level (Heating) (H/M/L) - - 33/29/25 dB(A)
9.5 kW: Sound Power Level (Cooling) (H/M/L) - - 56/52/48 dB
9.5 kW: Sound Power Level (Heating) (H/M/L) - - 56/52/48 dB
12.1 kW: Air Volume (Cooling) (H/M/L) - - 567/484/384 L/s
12.1 kW: Air Volume (Heating) (H/M/L) - - 567/484/384 L/s
12.1 kW: External Static Pressure - - 50 (10-150) Pa
12.1 kW: Sound Pressure Level (Cooling) (H/M/L) - - 35/31/27 dB(A)
12.1 kW: Sound Pressure Level (Heating) (H/M/L) - - 35/31/27 dB(A)
12.1 kW: Sound Power Level (Cooling) (H/M/L) - - 58/54/50 dB
12.1 kW: Sound Power Level (Heating) (H/M/L) - - 58/54/50 dB
13.4 kW: Air Volume (Cooling) (H/M/L) - - 601/534/417 L/s
13.4 kW: Air Volume (Heating) (H/M/L) - - 601/534/417 L/s
13.4 kW: External Static Pressure - - 50 (10-150) Pa
13.4 kW: Sound Pressure Level (Cooling) (H/M/L) - - 39/35/29 dB(A)
13.4 kW: Sound Pressure Level (Heating) (H/M/L) - - 39/35/29 dB(A)
13.4 kW: Sound Power Level (Cooling) (H/M/L) - - 62/58/52 dB
13.4 kW: Sound Power Level (Heating) (H/M/L) - - 62/58/52 dB

Source: Panasonic Australia, R32 Inverter NX Series Adaptive Ducted product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Panasonic R32 Inverter NX Series Splittable Ducted (PE4)

Panasonic's splittable ducted range from 6.0 kW to 22.4 kW (cooling). Panasonic states the indoor unit can be divided into sections, making it easier to move, deliver and install in tight spaces, and that higher external static pressure gives more flexibility for extended duct layouts. It lists nanoe™ X (Generator Mark3) and the CONEX remote control.

Key facts

  • Refrigerant: R32
  • Operation: Reverse Cycle (heating and cooling capacities published)
  • Indoor unit height: 300, 400 or 486 mm depending on model (as published)
  • Power supply: single phase and three phase options
  • Controllers listed: CONEX remote control (wired CZ-RTC5B and CZ-RTC4A also available)
  • S-160PE4RA is an underfloor installation model with an R32 leak detector
NX Series Splittable Ducted (PE4): models and rated capacities
Indoor unit Power supply Outdoor unit (Deluxe) Outdoor unit (Compact) Cooling (kW) Heating (kW)
S-60PE4R Single phase not listed U-60PZ4R5 6.0 6.0
S-71PE4R Single phase U-71PZH3R5 U-71PZ4R5 7.1 7.1/8.0
S-100PE4R Single phase U-100PZH3R5 U-100PZ4R5 10.0 12.5/10
S-100PE4R Three phase U-100PZH3R8 U-100PZ4R8 10.0 12.5/10.0
S-125PE4R Single phase U-125PZH3R5 U-125PZ4R5 12.5 14.0/12.5
S-125PE4R Three phase U-125PZH3R8 U-125PZ4R8 12.5 14.0/12.5
S-140PE4R Single phase U-140PZH3R5 U-140PZ4R5 14.0 16.0/14.0
S-140PE4R Three phase U-140PZH3R8 U-140PZ4R8 14.0 16.0/14.0
S-160PE4R/ S-160PE4RA* Single phase U-160PZH3R5 not listed 16.0 16.0
S-160PE4R/ S-160PE4RA* Three phase U-160PZH3R8 not listed 16.0 18.0
S-180PE4R Single phase U-180PZH3R5 not listed 18.0 20.0
S-180PE4R Three phase U-180PZH3R8 not listed 18.0 20.0
S-200PE4R Three phase U-200PZH3R8 not listed 20.0 22.4
S-224PE4R Three phase U-224PZH3R8 not listed 22.4 25.0

Cooling and heating figures are as published in the line up table on the official Panasonic product page. Where Panasonic shows two heating figures (for example 7.1/8.0) they are reproduced exactly as published. Panasonic does not publish a separate nominal size, so it is not shown.

Features listed by Panasonic

  • nanoe™ X air purification with Generator Mark3
  • Splittable chassis for easier installation in tight spaces
  • High static pressure and large air volume for design flexibility
  • Discharge air temperature control to reduce cold drafts during heating
  • Zoning to heat and cool rooms individually
  • Panasonic Comfort Cloud app control (WLAN adaptor required)

Official range page

*Underfloor installation model with an R32 leak detector (S-160PE4RA). The line up table shows the indoor and outdoor unit combinations published by Panasonic; a dash means no outdoor unit of that type is listed for that capacity.

Specifications: NX Series Splittable Ducted (PE4) line up (14 capacity and phase options)
NX Series Splittable Ducted (PE4) line up
Capacity (kW) Cooling 6.0 7.1 10.0 12.5 14.0 16.0 18.0 20.0 22.4
Capacity (kW) Heating 6.0 7.1/8.0 12.5/10 12.5/10.0 14.0/12.5 14.0/12.5 16.0/14.0 16.0/14.0 16.0 18.0 20.0 22.4 25.0
Power supply Single phase (1P) Single phase (1P) Single phase (1P) Three phase (3P) Single phase (1P) Three phase (3P) Single phase (1P) Three phase (3P) Single phase (1P) Three phase (3P) Single phase (1P) Three phase (3P) Three phase (3P) Three phase (3P)
Indoor Unit S-60PE4R S-71PE4R S-100PE4R S-125PE4R S-140PE4R S-160PE4R/ S-160PE4RA* S-180PE4R S-200PE4R S-224PE4R
Outdoor Unit (Deluxe) ー U-71PZH3R5 U-100PZH3R5 U-100PZH3R8 U-125PZH3R5 U-125PZH3R8 U-140PZH3R5 U-140PZH3R8 U-160PZH3R5 U-160PZH3R8 U-180PZH3R5 U-180PZH3R8 U-200PZH3R8 U-224PZH3R8
Outdoor Unit (Compact) U-60PZ4R5 U-71PZ4R5 U-100PZ4R5 U-100PZ4R8 U-125PZ4R5 U-125PZ4R8 U-140PZ4R5 U-140PZ4R8 ー ー ー ー ー ー

Source: Panasonic Australia, R32 Inverter NX Series Splittable Ducted product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Specifications: NX Series Splittable Ducted (PE4) indoor units (10 models)
NX Series Splittable Ducted (PE4) indoor units
Indoor unit S-60PE4R S-71PE4R S-100PE4R S-125PE4R S-140PE4R S-160PE4R S-160PE4RA S-180PE4R S-200PE4R S-224PE4R
Air Volume (Cooling) (H/M/L) 22.0/20.0/16.0 m³/min 30.0/26.0/22.0 m³/min 42.0/34.0/29.0 m³/min 50.0/46.0/36.0 m³/min 60.0/50.0/42.0 m³/min 60.0/50.0/42.0 m³/min 60.0/50.0/42.0 m³/min 1,202/1,052/885 Ls 1,202/1,052/885 Ls 1,402/1,202/985 Ls
Air Volume (Heating) (H/M/L) 22.0/20.0/16.0 m³/min 30.0/26.0/22.0 m³/min 42.0/34.0/29.0 m³/min 50.0/46.0/36.0 m³/min 60.0/50.0/42.0 m³/min 60.0/50.0/42.0 m³/min 60.0/50.0/42.0 m³/min 1,202/1,052/885 Ls 1,202/1,052/885 Ls 1,402/1,202/985 Ls
External Static Pressure 80 Pa (10/150 Pa) 80 Pa (10/150 Pa) 80 Pa (10/150 Pa) 80 Pa (10/150 Pa) 80 Pa (50/150 Pa) 80 Pa (50/150 Pa) 80 Pa (50/150 Pa) 60 Pa (100/150 Pa) 75 Pa (120/180 Pa) 75 Pa (130/200 Pa)
Sound Pressure Level (Cooling) (H/M/L) 38/36/32 dB(A) 43/39/35 dB(A) 42/37/34 dB(A) 42/39/34 dB(A) 45/41/37 dB(A) 45/41/37 dB(A) 45/41/37 dB(A) 46/44/41 dB (A) 46/44/41 dB (A) 47/45/42 dB (A)
Sound Pressure Level (Heating) (H/M/L) 38/36/32 dB(A) 43/39/35 dB(A) 42/37/34 dB(A) 42/39/34 dB(A) 45/41/37 dB(A) 45/41/37 dB(A) 45/41/37 dB(A) 46/44/41 dB (A) 46/44/41 dB (A) 47/45/42 dB (A)
Sound Power Level (Cooling) (H/M/L) 64/62/58 dB 69/65/61 dB 68/63/60 dB 68/65/60 dB 71/67/63 dB 71/67/63 dB 71/67/63 dB 78/76/73 dB 78/76/73 dB 79/77/74 dB
Sound Power Level (Heating) (H/M/L) 64/62/58 dB 69/65/61 dB 68/63/60 dB 68/65/60 dB 71/67/63 dB 71/67/63 dB 71/67/63 dB 78/76/73 dB 78/76/73 dB 79/77/74 dB
Current (Cooling) (rated) 1.06/0.94 A 1.46/1.34 A 1.82/1.70 A 1.83/1.71 A 2.61/2.61 A 2.61/2.47 A 2.61/2.47 A 3.30/3.20 A 3.40/3.30 A 4.20/4.10 A
Current (Heating) (rated) 1.06/0.94 A 1.46/1.34 A 1.82/1.70 A 1.83/1.71 A 2.47/2.47 A 2.61/2.47 A 2.61/2.47 A 3.30/3.20 A 3.40/3.30 A 4.20/4.10 A
Dimension H300 x W1,297 x D877 mm H300 x W1,297 x D877 mm H300 x W1,297 x D877 mm H400 x W1,297 x D949 mm H400 x W1,297 x D949 mm H400 X W1,297 X D949 mm H400 X W1,297 X D949 mm H486 x W1,456 x D916 mm H486 x W1,456 x D916 mm H486 x W1,456 x D916 mm
Net Weight 51 kg 51 kg 51 kg 61 kg 61 kg 61 kg 61 kg 82 kg 83 kg 87 kg
Number of Fan Speeds 5 5 5 5 5 5 5 3 3 3
Drain Piping VP-25 mm VP-25 mm VP-25 mm VP-25 mm VP-25 mm VP-25 mm VP-25 mm VP-25 mm VP-25 mm VP-25 mm

Source: Panasonic Australia, R32 Inverter NX Series Splittable Ducted product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

How we install a Panasonic ducted system in Melbourne

  1. Enquiry and assessment. We discuss the rooms you want to heat and cool, then assess the home, including room sizes, insulation, windows and orientation, and where the indoor and outdoor units can go.
  2. Recommendation and written quote. We recommend a Panasonic ducted range and capacity that suits the home and explain the options before you commit.
  3. Installation. Our team installs the indoor and outdoor units, runs the refrigerant pipework and condensate drain, and completes the electrical connection as required by Victorian regulations.
  4. Commissioning and handover. We test heating and cooling operation, set up the controller and show you how to use the system and look after the filters.
  5. Ongoing service. Regular maintenance keeps the system running efficiently. See our maintenance services.

Manufacturer warranty

Panasonic Australia states on its air conditioning pages: "With a 5-year warranty encompassing both residential and commercial application, you can rest easily with Panasonic." Warranty terms and conditions are set by Panasonic Australia; see Panasonic Australia's air conditioning pages or ask us for details with your quote.

Victorian Energy Upgrades

EZYAIR is a Victorian Energy Upgrades (VEU) accredited provider (A2261). If you are replacing an older heater with an efficient reverse cycle system, ask us whether your project may be eligible for a VEU discount. Eligibility depends on the existing heater, the new product and the program rules at the time. Learn more on our Victorian Energy Upgrades page.

You can see a range of wall hung, ducted and bulkhead units on display, many of them operational, at our Burwood showroom at 49 Huntingdale Rd, Burwood VIC 3125.

Related pages

Panasonic ducted air conditioning FAQs

Which Panasonic ducted unit suits a home with limited ceiling space?

Panasonic lists the Ultra Slim Ducted (UD3) at only 200 mm high and the Adaptive Ducted (PF3) at 250 mm high. The Splittable Ducted (PE4) indoor unit can be divided into sections to move it into tight spaces. We inspect the roof or ceiling space before recommending a unit.

What size Panasonic ducted system does a large Melbourne home need?

It depends on floor area, insulation, glazing and zoning. The Panasonic ducted ranges listed here span 2.6 kW to 22.4 kW cooling. We calculate the heat load before recommending a capacity.

Can a Panasonic ducted system be zoned?

Panasonic describes zoning for its ducted systems, so you can heat or cool selected rooms and turn off airflow to rooms that are not in use. We design the zones with you.

Can EZYAIR replace my gas ducted heating with a Panasonic ducted system?

Yes. We replace older ducted heating with reverse cycle ducted systems. As a VEU accredited provider (A2261) we can check whether your project may be eligible for a Victorian Energy Upgrades discount.

What warranty applies to Panasonic ducted air conditioning?

Panasonic Australia states: "With a 5-year warranty encompassing both residential and commercial application, you can rest easily with Panasonic." Terms and conditions are set by Panasonic Australia.

Do Panasonic ducted systems include air purification?

Panasonic lists nanoe™ X air purification for the NX Series Adaptive Ducted (PF3) and NX Series Splittable Ducted (PE4) ranges, with the PE4 using the newer Generator Mark3. The Ultra Slim Ducted (UD3) listing does not mention nanoe™ X.

Can a Panasonic ducted unit connect to a multi split system?

Yes. Panasonic states the Ultra Slim Ducted (UD3) can be paired with its own outdoor unit or connected to a Panasonic multi split system, which suits a concealed bulkhead unit in one room alongside other indoor units.

Request a quote

Planning Panasonic ducted air conditioning for your Melbourne home? Contact EZYAIR or call 1300 EZYAIR (1300 399 247).

You have successfully subscribed!