Fujitsu Ducted Air Conditioning Melbourne

A Fujitsu ducted reverse cycle system heats and cools the whole home from one concealed indoor unit, with air delivered through ducts to discreet ceiling or floor outlets. EZYAIR designs, supplies and installs Fujitsu ducted air conditioning across Melbourne, from apartments and townhouses to large family homes. Request a Fujitsu ducted air conditioning quote or call 1300 EZYAIR (1300 399 247).

Is Fujitsu ducted air conditioning right for your home?

Ducted air conditioning suits Melbourne homes that want consistent comfort through cold winters and hot summers without wall mounted units in every room. A ducted system needs space for the indoor unit in the roof, ceiling or under the floor, and a suitable location for the outdoor unit. With zoning, you can choose which areas are heated or cooled. If you only need to condition one or two rooms, a Fujitsu split system or a Fujitsu multi split system may be a better fit.

Current Fujitsu ducted ranges

The following reverse cycle ducted ranges (up to 25kW) and bulkhead units are listed on the official GENERAL Australia website at the time of writing (October 2026) and are the Fujitsu ducted systems we supply and install. Select a range to jump to its details.

EZYAIR is an independent air conditioning installer. Product information on this page is copied from the official GENERAL Australia (Fujitsu) website and brochures. Figures are as published by the manufacturer. Where a figure is not published it is not shown. Tables scroll sideways on smaller screens.

Fujitsu High Static Single Phase R32

A whole home range of six single phase models from 7.1 kW to 15.5 kW cooling. The manufacturer states a guaranteed operating range of up to 50°C in cooling, demand response capability and zone system compatibility.

Key facts

  • Refrigerant: R32
  • Operation: Reverse Cycle
  • Compatible controller options listed: UTY-RVNYN
High Static Single Phase R32: models and rated capacities
Model Cooling (kW) Heating (kW)
ARTH24KHTA 7.10 8.00
ARTH30KHTA 8.50 10.00
ARTH36KHTA 10.00 11.20
ARTH45KHTA 12.50 14.00
ARTH54KHTA 14.00 15.50
ARTH60KHTA 15.50 18.00

Cooling and heating figures are rated capacities as published by the manufacturer.

Features listed by the manufacturer

  • Zone Control
  • Auto Restart
  • Auto Changeover
  • Blue Fin Heat Exchanger
  • Connectable Distributing Duct
  • Connectable Fresh Air Duct
  • Demand Response
  • All DC
  • Economy Mode
  • Filter Sign
  • On-Off Timer
  • Program Timer
  • Weekly Timer
  • Operating Temperature Range 50°C
  • Demo Mode
  • Automatic Static Pressure Setting Adjustment

Official High Static Single Phase R32 brochure (GENERAL Australia on Issuu) | Official range page

Specifications: High Static Single Phase R32 (6 models)
High Static Single Phase R32
Model ARTH24KHTA ARTH30KHTA ARTH36KHTA ARTH45KHTA ARTH54KHTA ARTH60KHTA
Power supply Single phase (1P) Single phase (1P) Single phase (1P) Single phase (1P) Single phase (1P) Single phase (1P)
Operation Type Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 7.10 (1.8 - 8.1) 8.50 (2.8 - 10.3) 10.00 (2.8 - 11.4) 12.50 (4 - 14) 14.00 (4.5 - 15) 15.50 (5 - 16.5)
Heating Capacity kW (Rated (Min - Max)) 8.00 (2 - 9.1) 10.00 (2.7 - 11.3) 11.20 (2.7 - 14) 14.00 (4.2 - 16.5) 15.50 (4.7 - 18) 18.00 (5.1 - 19)
Input Power Cooling kW (Rated (Max)) 2.14 (2.53) 2.35 (3.47) 3.08 (4.01) 3.8 (5.16) 4.64 (5.17) 4.94 (6.02)
Input Power Heating kW (Rated (Max)) 2.05 (2.45) 2.35 (4.12) 2.8 (4.21) 3.42 (5.22) 4.4 (5.23) 4.89 (6.74)
EER Cooling kW/kW 3.32 3.62 3.25 3.29 3.02 3.14
COP Heating kW/kW 3.9 4.26 4 4.09 3.52 3.68
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 3 / 3 3 / 2.5 / 3 3 / 2.5 / 3 3 / 2.5 / 3 2.5 / 2.5 / 2.5 2.5 / 2.5 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 2.5 / 1.5 3 / 2.5 / 2 3 / 2.5 / 1.5 3 / 2.5 / 2 3 / 2 / 1.5 2.5 / 2 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.912 / 4.611 / 4.875 4.695 / 4.469 / 4.637 4.642 / 4.426 / 4.675 4.612 / 4.403 / 4.635 4.339 / 4.147 / 4.39 4.378 / 4.193 / 4.416
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.825 / 4.11 / 3.444 4.61 / 4.211 / 3.654 4.72 / 4.073 / 3.429 4.766 / 4.208 / 3.574 4.691 / 3.937 / 3.306 4.487 / 3.885 / 3.31
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.299 / 5.489 / 5.931 4.982 / 5.065 / 5.397 4.972 / 5.144 / 5.544 4.928 / 5.083 / 5.465 4.647 / 4.816 / 5.195 4.673 / 4.821 / 5.181
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.831 / 4.41 / 3.707 4.6 / 4.35 / 3.895 4.72 / 4.34 / 3.67 4.764 / 4.41 / 3.901 4.706 / 4.101 / 3.573 4.491 / 4.135 / 3.523
Running Current amps (Cooling / Heating) 9.4 / 9 10.4 / 10.4 13.6 / 12.3 16.7 / 15 20.4 / 19.3 21.7 / 21.4
Moisture Removal l/hr 0.5 0.1 1.4 0.9 1.6 2.8
Indoor Sound Pressure Cooling dBA (High / Quiet) 34 / 27 41 / 36 41 / 36 43 / 35 45 / 36 45 / 36
Indoor Sound Pressure Heating dBA (High / Quiet) 34 / 27 41 / 36 41 / 36 43 / 35 45 / 36 45 / 36
Outdoor Sound Pressure dBA (Cooling / Heating) 48 / 50 51 / 53 53 / 53 55 / 57 55 / 57 53 / 55
Outdoor Sound Power dBA 68 69 70 71 72 71
Static Pressure Range PA (Min to Max) 60 to 210 60 to 210 60 to 210 60 to 260 60 to 260 60 to 260
Air Circulation (Indoor - High Fan) Cooling l/sec 500 695 695 903 986 986
Air Circulation (Indoor - High Fan) Heating l/sec 500 695 695 903 986 986
Indoor Unit Dimensions mm (Height x Width x Depth) 400 x 1050 x 500 400 x 1050 x 500 400 x 1050 x 500 425 x 1250 x 490 425 x 1250 x 490 425 x 1250 x 490
Indoor Unit Weight kg 38.00 39.00 39.00 53.00 53.00 53.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 716 x 820 x 315 788 x 940 x 320 788 x 940 x 320 998 x 940 x 320 998 x 940 x 320 1418 x 970 x 370
Outdoor Unit Weight kg 42.00 52.00 52.00 67.00 67.00 95.00
Piping Connects mm Ø (Liquid / Gas) 6.35 / 12.7 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Pipe Length m (Max (Precharged)) 30 (20) 50 (30) 50 (30) 50 (30) 50 (30) 50 (30)
Max Height Difference m 25 30 30 30 30 30
Operation Range Cooling °CDB (Min to Max) -10 to 50 -10 to 50 -10 to 50 -10 to 50 -10 to 50 -10 to 50
Operation Range Heating °CDB (Min to Max) -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24
Refrigerant Type R32 R32 R32 R32 R32 R32
Refrigerant Amount g 1,250 1,900 1,900 2,700 2,700 2,550
Return Air Connection (H x W) 325 x 865 325 x 865 325 x 865 351 x 1062 351 x 1062 351 x 1062
Supply Air Connection (H x W) 295 x 850 295 x 850 295 x 850 304 x 921 304 x 921 304 x 921
UART Communication Yes Yes Yes Yes Yes Yes
UART Communication Port 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75

Source: GENERAL Australia (Fujitsu), High Static Single Phase R32 range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Fujitsu High Static Single Phase R32 (HP)

The high performance version of the High Static Single Phase R32 range, with five models from 8.5 kW to 16 kW cooling, also zone system compatible.

Key facts

  • Refrigerant: R32
  • Operation: Reverse Cycle
  • Compatible controller options listed: UTY-RNRT
High Static Single Phase R32 (HP): models and rated capacities
Model Cooling (kW) Heating (kW)
ARTH30KHTA-HP 8.50 10.00
ARTH36KHTA-HP 10.00 12.50
ARTH45KHTA-HP 12.50 15.00
ARTH54KHTA-HP 14.00 16.50
ARTH60KHTB 16.00 18.00

Cooling and heating figures are rated capacities as published by the manufacturer.

Features listed by the manufacturer

  • Zone Control
  • Auto Restart
  • Auto Changeover
  • Blue Fin Heat Exchanger
  • Connectable Distributing Duct
  • Connectable Fresh Air Duct
  • Demand Response
  • Economy Mode
  • Filter Sign
  • On-Off Timer
  • Program Timer
  • Weekly Timer
  • Operating Temperature Range 50°C
  • Demo Mode
  • Automatic Static Pressure Setting Adjustment
  • All DC
  • Long Piping Capability 75m

Official High Static Single Phase R32 (HP) brochure (GENERAL Australia on Issuu) | Official range page

Specifications: High Static Single Phase R32 (HP) (5 models)
High Static Single Phase R32 (HP)
Model ARTH30KHTA-HP ARTH36KHTA-HP ARTH45KHTA-HP ARTH54KHTA-HP ARTH60KHTB
Power supply Single phase (1P) Single phase (1P) Single phase (1P) Single phase (1P) Single phase (1P)
Operation Type Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 8.50 (4.1 - 11) 10.00 (5 - 13) 12.50 (5.6 - 14.5) 14.00 (6.3 - 16.5) 16.00 (7.4 - 17.5)
Heating Capacity kW (Rated (Min - Max)) 10.00 (4.2 - 12) 12.50 (5.2 - 15) 15.00 (5.2 - 17) 16.50 (5.8 - 18.5) 18.00 (7.4 - 20.5)
Input Power Cooling kW (Rated (Max)) 2.18 (3.36) 2.6 (5.01) 3.43 (4.39) 3.91 (5.35) 4.82 (5.31)
Input Power Heating kW (Rated (Max)) 2.2 (3.12) 2.94 (4.65) 3.49 (4.46) 4 (4.49) 4.63 (5.19)
EER Cooling kW/kW 3.9 3.85 3.61 3.58 3.32
COP Heating kW/kW 4.55 4.25 4.3 4.13 3.89
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 3 / 3 3 / 3 / 3 3 / 3 / 3 3 / 2.5 / 3 3 / 2.5 / 3
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 3 / 2 3 / 2.5 / 2 3 / 2.5 / 2 2.5 / 2.5 / 2 3 / 2.5 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.833 / 4.593 / 4.727 4.964 / 4.727 / 4.9 4.785 / 4.573 / 4.76 4.666 / 4.464 / 4.642 4.533 / 4.342 / 4.555
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.856 / 4.509 / 3.994 4.912 / 4.377 / 3.733 4.702 / 4.305 / 3.753 4.4 / 4.028 / 3.502 4.521 / 4.001 / 3.428
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.108 / 5.148 / 5.458 5.264 / 5.347 / 5.694 5.079 / 5.18 / 5.528 4.947 / 5.04 / 5.375 4.828 / 4.962 / 5.32
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.843 / 4.624 / 4.201 4.909 / 4.58 / 4.043 4.693 / 4.446 / 3.992 4.388 / 4.154 / 3.729 4.519 / 4.195 / 3.734
Running Current amps (Cooling / Heating) 9.6 / 9.7 11.4 / 12.9 15.1 / 15.3 17.2 / 17.5 21.1 / 20.3
Moisture Removal l/hr 0.1 1.4 0.9 1.6 3.4
Indoor Sound Pressure Cooling dBA (High / Quiet) 41 / 36 41 / 36 43 / 35 45 / 36 44 / 39
Indoor Sound Pressure Heating dBA (High / Quiet) 41 / 36 41 / 36 43 / 35 45 / 36 44 / 39
Outdoor Sound Pressure dBA (Cooling / Heating) 51 / 53 53 / 53 53 / 53 53 / 55 53 / 55
Outdoor Sound Power dBA 69 70 70 71 71
Static Pressure Range PA (Min to Max) 60 to 210 60 to 210 60 to 260 60 to 260 60 to 250
Air Circulation (Indoor - High Fan) Cooling l/sec 695 695 903 986 1139
Air Circulation (Indoor - High Fan) Heating l/sec 695 695 903 986 1139
Indoor Unit Dimensions mm (Height x Width x Depth) 400 x 1050 x 500 400 x 1050 x 500 425 x 1250 x 490 425 x 1250 x 490 360 x 1400 x 850
Indoor Unit Weight kg 39.00 39.00 53.00 53.00 69.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 998 x 940 x 320 998 x 940 x 320 1418 x 970 x 370 1418 x 970 x 370 1418 x 970 x 370
Outdoor Unit Weight kg 64.00 67.00 95.00 101.00 101.00
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Pipe Length m (Max (Precharged)) 75 (30) 75 (30) 75 (30) 75 (30) 75 (30)
Max Height Difference m 30 30 30 30 30
Operation Range Cooling °CDB (Min to Max) -10 to 50 -10 to 50 -10 to 50 -10 to 50 -10 to 50
Operation Range Heating °CDB (Min to Max) -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24
Refrigerant Type R32 R32 R32 R32 R32
Refrigerant Amount g 2,100 2,500 3,400 3,800 3,800
Return Air Connection (H x W) 325 x 865 325 x 865 351 x 1062 351 x 1062 316 x 1295
Supply Air Connection (H x W) 295 x 850 295 x 850 304 x 921 304 x 921 277 x 1162
UART Communication Yes Yes Yes Yes Yes
UART Communication Port 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75

Source: GENERAL Australia (Fujitsu), High Static Single Phase R32 (HP) range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Fujitsu Large Capacity High Static Single Phase

A large capacity single phase ducted model for bigger homes. The manufacturer notes touch panel and Wi-Fi control options.

Key facts

  • Refrigerant: R32
  • Operation: Reverse Cycle
  • Compatible controller options listed: UTY-RNRT
Large Capacity High Static Single Phase: models and rated capacities
Model Cooling (kW) Heating (kW)
ARTH65KHTA 18.00 20.00

Cooling and heating figures are rated capacities as published by the manufacturer.

Features listed by the manufacturer

  • Automatic Static Pressure Setting Adjustment
  • All DC
  • Auto Restart
  • Auto Changeover
  • Blue Fin Heat Exchanger
  • Connectable Distributing Duct
  • Connectable Fresh Air Duct
  • Demo Mode
  • Demand Response
  • Economy Mode
  • Filter Sign
  • Program Timer
  • Fresh Air Intake
  • Operating Temperature Range 50°C
  • On-Off Timer
  • Weekly Timer
  • Zone Control

Official Large Capacity High Static Single Phase brochure (GENERAL Australia on Issuu) | Official range page

Specifications: Large Capacity High Static Single Phase (1 models)
Large Capacity High Static Single Phase
Model ARTH65KHTA
Power supply Single phase (1P)
Operation Type Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50
Capacity Class kW 18
Cooling Capacity kW (Rated (Min - Max)) 18.00 (5.5 - 20)
Heating Capacity kW (Rated (Min - Max)) 20.00 (5.5 - 22.4)
Input Power Cooling kW (Rated (Max)) 5.61 (7.8)
Input Power Heating kW (Rated (Max)) 5.24 (6.86)
EER Cooling kW/kW 3.21
COP Heating kW/kW 3.82
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 2.5 / 3
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 2.5 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.532 / 4.343 / 4.585
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.503 / 4.001 / 3.446
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.842 / 5.006 / 5.389
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.503 / 4.192 / 3.732
Running Current amps (Cooling / Heating) 24.6 / 23
Moisture Removal l/hr 4
Indoor Sound Pressure Cooling dBA (High / Quiet) 44 / 35
Indoor Sound Pressure Heating dBA (High / Quiet) 44 / 35
Outdoor Sound Pressure dBA (Cooling / Heating) 57 / 58
Outdoor Sound Power dBA 74
Static Pressure Range PA (Min to Max) 60 to 200
Air Circulation (Indoor - High Fan) Cooling l/sec 1139
Air Circulation (Indoor - High Fan) Heating l/sec 1139
Indoor Unit Dimensions mm (Height x Width x Depth) 360 x 1400 x 850
Indoor Unit Weight kg 69.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 1418 x 970 x 370
Outdoor Unit Weight kg 101.00
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88
Pipe Length m (Max (Precharged)) 75 (30)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -15 to 50
Operation Range Heating °CDB (Min to Max) -20 to 24
Refrigerant Type R32
Refrigerant Amount g 3,800

Source: GENERAL Australia (Fujitsu), Large Capacity High Static Single Phase range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Fujitsu Mid Static Slimline R32

Slimline ducted units with an indoor unit 240 mm high and a built in drain pump, designed for tighter bulkhead and ceiling spaces such as apartments, townhouses and single storey homes with limited roof space.

Key facts

  • Refrigerant: R32
  • Operation: Reverse Cycle
Mid Static Slimline R32: models and rated capacities
Model Cooling (kW) Heating (kW)
ARTH18KMTAP 5.00 6.00
ARTH24KMTAP 7.10 8.00
ARTH30KMTAP 8.50 10.00
ARTH36KMTAP 10.00 11.20
ARTH45KMTAP 12.50 14.00
ARTH54KMTAP 13.00 15.00

Cooling and heating figures are rated capacities as published by the manufacturer.

Features listed by the manufacturer

  • In-Built Safety Tray
  • Program Timer
  • Economy Mode
  • Zone Control
  • Auto Restart
  • Auto Changeover
  • Blue Fin Heat Exchanger
  • Connectable Fresh Air Duct
  • Connectable Distributing Duct
  • Demand Response
  • Filter Sign
  • On-Off Timer
  • Weekly Timer
  • Operating Temperature Range 50°C
  • Demo Mode

Official Mid Static Slimline R32 brochure (GENERAL Australia on Issuu) | Official range page

Specifications: Mid Static Slimline R32 (6 models)
Mid Static Slimline R32
Model ARTH18KMTAP ARTH24KMTAP ARTH30KMTAP ARTH36KMTAP ARTH45KMTAP ARTH54KMTAP
Power supply Single phase (1P) Single phase (1P) Single phase (1P) Single phase (1P) Single phase (1P) Single phase (1P)
Operation Type Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 5.00 (0.9 - 6.4) 7.10 (1.8 - 8.1) 8.50 (2.8 - 10.3) 10.00 (2.8 - 11.4) 12.50 (4 - 14) 13.00 (4.5 - 15)
Heating Capacity kW (Rated (Min - Max)) 6.00 (0.9 - 7.8) 8.00 (2 - 9.1) 10.00 (2.7 - 11.3) 11.20 (2.7 - 14) 14.00 (4.2 - 16.5) 15.00 (4.7 - 18)
Input Power Cooling kW (Rated (Max)) 1.37 (1.95) 2.15 (2.92) 2.6 (4.28) 3.23 (4.3) 4 (5.18) 4.31 (5.19)
Input Power Heating kW (Rated (Max)) 1.58 (2.39) 2.19 (2.67) 2.62 (4.44) 3.3 (4.5) 4 (5.22) 4.45 (5.23)
EER Cooling kW/kW 3.65 3.3 3.5461 3.1914 3.13 3.02
COP Heating kW/kW 3.8 3.65 4.1151 3.7299 3.5 3.37
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 2.5 / 2 3 / 2 / 1.5 2.5 / 2.5 / 2.5 2.5 / 2.5 / 2.5 3 / 2 / 1.5 2.5 / 2 / 1.5
Star Rating Heating (0-10) (Hot / Average / Cold) 3.5 / 3 / 3 3 / 2.5 / 2.5 3 / 2.5 / 2 3 / 2 / 1.5 2.5 / 2.5 / 3 2.5 / 2.5 / 2.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 5.012 / 4.663 / 4.844 4.558 / 4.294 / 4.484 4.781 / 4.91 / 5.264 4.338 / 4.141 / 4.359 4.462 / 4.265 / 4.509 4.354 / 4.163 / 4.412
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.74 / 4.182 / 3.616 4.694 / 3.996 / 3.375 5.036 / 4.472 / 3.899 4.568 / 3.815 / 3.201 4.512 / 3.881 / 3.295 4.371 / 3.688 / 3.113
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.377 / 5.485 / 5.866 4.878 / 4.999 / 5.356 4.781 / 4.91 / 5.264 4.635 / 4.781 / 5.14 4.775 / 4.943 / 5.327 4.664 / 4.837 / 5.221
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.747 / 4.409 / 3.923 4.704 / 4.291 / 3.622 4.731 / 4.361 / 3.834 4.583 / 4.139 / 3.467 4.522 / 4.129 / 3.641 4.382 / 3.98 / 3.356
Running Current amps (Cooling / Heating) 5.9 / 6.8 9.1 / 9.2 11 / 11.2 13.6 / 13.9 16.8 / 16.8 18.1 / 18.7
Moisture Removal l/hr 1.3 1.7 1.6 2.9 4.5 5
Indoor Sound Pressure Cooling dBA (High / Quiet) 33 / 23 38 / 27 38 / 28 38 / 27 40 / 29 40 / 29
Indoor Sound Pressure Heating dBA (High / Quiet) 33 / 23 38 / 27 38 / 28 38 / 27 40 / 29 40 / 29
Outdoor Sound Pressure dBA (Cooling / Heating) 48 / 49 48 / 50 51 / 53 53 / 53 55 / 57 55 / 57
Outdoor Sound Power dBA 62 68 69 70 71 72
Static Pressure Range PA (Min to Max) 50 to 150 50 to 150 50 to 150 50 to 150 50 to 150 50 to 150
Air Circulation (Indoor - High Fan) Cooling l/sec 300 416.67 541.67 575 600 600
Air Circulation (Indoor - High Fan) Heating l/sec 300 416.67 541.67 575 600 600
Indoor Unit Dimensions mm (Height x Width x Depth) 240 x 1000 x 700 240 x 1000 x 700 240 x 1400 x 700 240 x 1400 x 700 240 x 1400 x 700 240 x 1400 x 700
Indoor Unit Weight kg 31.00 31.00 42.00 42.00 42.00 42.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 632 x 799 x 290 716 x 820 x 315 788 x 940 x 320 788 x 940 x 320 998 x 940 x 320 998 x 940 x 320
Outdoor Unit Weight kg 36.00 42.00 52.00 52.00 67.00 67.00
Piping Connects mm Ø (Liquid / Gas) 6.35 / 12.7 6.35 / 12.7 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Pipe Length m (Max (Precharged)) 30 (20) 30 (20) 50 (30) 50 (30) 50 (30) 50 (30)
Max Height Difference m 20 25 30 30 30 30
Operation Range Cooling °CDB (Min to Max) -10 to 50 -10 to 50 -10 to 50 -10 to 50 -10 to 50 -10 to 50
Operation Range Heating °CDB (Min to Max) -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24 -15 to 24
Refrigerant Type R32 R32 R32 R32 R32 R32
Refrigerant Amount g 1,020 1,250 1,900 1,900 2,700 2,700
Return Air Connection (H x W) 195 x 895 195 x 895 195 x 1295 195 x 1295 195 x 1295 195 x 1295
Supply Air Connection (H x W) 177 x 790 177 x 790 177 x 1190 177 x 1190 177 x 1190 177 x 1190
UART Communication Yes Yes Yes Yes Yes Yes
UART Communication Port 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75

Source: GENERAL Australia (Fujitsu), Mid Static Slimline R32 range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Fujitsu Mid Static Slimline R32 (HP)

A high performance version of the Mid Static Slimline R32. The manufacturer quotes a maximum pipe length of 75 m, making these models suited to installations where the outdoor unit is on a roof or in a plant room of an apartment building.

Key facts

  • Refrigerant: R32
  • Operation: Reverse Cycle
Mid Static Slimline R32 (HP): models and rated capacities
Model Cooling (kW) Heating (kW)
ARTH24KMTAP-HP 7.10 8.00
ARTH30KMTAP-HP 8.50 10.00

Cooling and heating figures are rated capacities as published by the manufacturer.

Features listed by the manufacturer

  • Zone Control
  • Auto Restart
  • Auto Changeover
  • Blue Fin Heat Exchanger
  • Connectable Distributing Duct
  • Connectable Fresh Air Duct
  • Demand Response
  • Economy Mode
  • Filter Sign
  • On-Off Timer
  • Program Timer
  • Weekly Timer
  • In-Built Drain Pump
  • Operating Temperature Range 50°C
  • Demo Mode
  • Long Piping Capability 75m

Official Mid Static Slimline R32 (HP) brochure (GENERAL Australia on Issuu) | Official range page

Specifications: Mid Static Slimline R32 (HP) (2 models)
Mid Static Slimline R32 (HP)
Model ARTH24KMTAP-HP ARTH30KMTAP-HP
Power supply Single phase (1P) Single phase (1P)
Operation Type Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 7.10 (3.3 - 8.5) 8.50 (4.1 - 10.5)
Heating Capacity kW (Rated (Min - Max)) 8.00 (3.6 - 10.5) 10.00 (4.2 - 11.5)
Input Power Cooling kW (Rated (Max)) 1.85 (2.72) 2.26 (3.38)
Input Power Heating kW (Rated (Max)) 1.93 (2.89) 2.47 (3.12)
EER Cooling kW/kW 3.84 3.76
COP Heating kW/kW 4.15 4.05
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 2.5 / 2.5 3.5 / 2.5 / 2
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 2.5 / 3 3 / 3 / 3
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.712 / 4.474 / 4.598 4.8 / 4.569 / 4.727
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.962 / 4.491 / 4.043 5.036 / 4.472 / 3.899
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.976 / 5.005 / 5.302 5.084 / 5.154 / 5.481
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.964 / 4.288 / 4.679 5.043 / 4.702 / 4.207
Running Current amps (Cooling / Heating) 8 / 8.4 9.6 / 10.5
Moisture Removal l/hr 1.7 1.6
Indoor Sound Pressure Cooling dBA (High / Quiet) 38 / 27 38 / 28
Indoor Sound Pressure Heating dBA (High / Quiet) 38 / 27 38 / 28
Outdoor Sound Pressure dBA (Cooling / Heating) 48 / 50 51 / 53
Outdoor Sound Power dBA 67 69
Static Pressure Range PA (Min to Max) 50 to 150 50 to 150
Air Circulation (Indoor - High Fan) Cooling l/sec 416.67 541.67
Air Circulation (Indoor - High Fan) Heating l/sec 416.67 541.67
Indoor Unit Dimensions mm (Height x Width x Depth) 240 x 1000 x 700 240 x 1400 x 700
Indoor Unit Weight kg 31.00 42.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 988 x 940 x 320 998 x 940 x 320
Outdoor Unit Weight kg 63.00 64.00
Piping Connects mm Ø (Liquid / Gas) 6.35 / 12.7 9.52 / 15.88
Pipe Length m (Max (Precharged)) 75 (30) 75 (30)
Max Height Difference m 30 30
Operation Range Cooling °CDB (Min to Max) -10 to 50 -10 to 50
Operation Range Heating °CDB (Min to Max) -15 to 24 -15 to 24
Refrigerant Type R32 R32
Refrigerant Amount g 1,800 2,100
Return Air Connection (H x W) 195 x 895 195 x 1295
Supply Air Connection (H x W) 177 x 790 177 x 1190
UART Communication Yes Yes
UART Communication Port 2 Ports - CN65, CN75 2 Ports - CN65, CN75

Source: GENERAL Australia (Fujitsu), Mid Static Slimline R32 (HP) range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Fujitsu High Static Three Phase R32

Four three phase models from 10 kW to 15.5 kW cooling for larger houses with a three phase supply, with demand response and zone system compatibility.

Key facts

  • Refrigerant: R32
  • Operation: Reverse Cycle
  • Compatible controller options listed: UTY-RVNYN
High Static Three Phase R32: models and rated capacities
Model Cooling (kW) Heating (kW)
ARTH36KHTA-3PH 10.00 11.20
ARTH45KHTA-3PH 12.50 14.00
ARTH54KHTA-3PH 14.00 15.50
ARTH60KHTA-3PH 15.50 18.00

Cooling and heating figures are rated capacities as published by the manufacturer.

Features listed by the manufacturer

  • Automatic Static Pressure Setting Adjustment
  • All DC
  • Auto Restart
  • Auto Changeover
  • Blue Fin Heat Exchanger
  • Connectable Distributing Duct
  • Connectable Fresh Air Duct
  • Demo Mode
  • Demand Response
  • Economy Mode
  • Filter Sign
  • Program Timer
  • Fresh Air Intake
  • Operating Temperature Range 50°C
  • On-Off Timer
  • Weekly Timer
  • Zone Control

Official High Static Three Phase R32 brochure (GENERAL Australia on Issuu) | Official range page

Specifications: High Static Three Phase R32 (4 models)
High Static Three Phase R32
Model ARTH36KHTA-3PH ARTH45KHTA-3PH ARTH54KHTA-3PH ARTH60KHTA-3PH
Power supply Three phase (3P) Three phase (3P) Three phase (3P) Three phase (3P)
Operation Type Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50
Cooling Capacity kW (Rated (Min - Max)) 10.00 (2.8 - 11.4) 12.50 (4 - 14) 14.00 (4.5 - 15) 15.50 (5 - 16.5)
Heating Capacity kW (Rated (Min - Max)) 11.20 (2.7 - 14) 14.00 (4.2 - 16.5) 15.50 (4.7 - 18) 18.00 (5.1 - 19)
Input Power Cooling kW (Rated (Max)) 3.08 (4.01) 3.8 (5.16) 4.64 (5.17) 4.94 (6.02)
Input Power Heating kW (Rated (Max)) 2.8 (4.21) 3.42 (5.22) 4.4 (5.23) 4.89 (6.74)
EER Cooling kW/kW 3.25 3.29 3.02 3.14
COP Heating kW/kW 4 4.09 3.52 3.68
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 2.5 / 3 3 / 2.5 / 3 2.5 / 2.5 / 2.5 2.5 / 2.5 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 2.5 / 1.5 3 / 2.5 / 2 3 / 2 / 1.5 2.5 / 2 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.642 / 4.426 / 4.675 4.612 / 4.403 / 4.635 4.339 / 4.147 / 4.39 4.378 / 4.193 / 4.416
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.72 / 4.073 / 3.429 4.766 / 4.208 / 3.574 4.691 / 3.937 / 3.306 4.487 / 3.885 / 3.31
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.972 / 5.144 / 5.544 4.928 / 5.083 / 5.465 4.647 / 4.816 / 5.195 4.673 / 4.821 / 5.181
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.72 / 4.34 / 3.67 4.764 / 4.41 / 3.901 4.706 / 4.101 / 3.573 4.491 / 4.135 / 3.523
Running Current amps (Cooling / Heating) 5.2 / 4.7 6.4 / 5.7 7.7 / 7 7.8 / 7.9
Moisture Removal l/hr 1.4 0.9 1.6 2.8
Indoor Sound Pressure Cooling dBA (High / Quiet) 41 / 36 43 / 35 45 / 36 45 / 36
Indoor Sound Pressure Heating dBA (High / Quiet) 41 / 36 43 / 35 45 / 36 45 / 36
Outdoor Sound Pressure dBA (Cooling / Heating) 53 / 53 55 / 57 55 / 57 53 / 55
Outdoor Sound Power dBA 70 71 72 71
Static Pressure Range PA (Min to Max) 60 to 210 60 to 260 60 to 260 60 to 260
Air Circulation (Indoor - High Fan) Cooling l/sec 695 903 986 986
Air Circulation (Indoor - High Fan) Heating l/sec 695 903 986 986
Indoor Unit Dimensions mm (Height x Width x Depth) 400 x 1050 x 500 425 x 1250 x 490 425 x 1250 x 490 425 x 1250 x 490
Indoor Unit Weight kg 39.00 53.00 53.00 53.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 788 x 940 x 320 998 x 940 x 320 998 x 940 x 320 1418 x 970 x 370
Outdoor Unit Weight kg 53.00 67.00 67.00 96.00
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Pipe Length m (Max (Precharged)) 50 (30) 50 (30) 50 (30) 50 (30)
Max Height Difference m 30 30 30 30
Operation Range Cooling °CDB (Min to Max) -10 to 50 -10 to 50 -10 to 50 -10 to 50
Operation Range Heating °CDB (Min to Max) -15 to 24 -15 to 24 -15 to 24 -15 to 24
Refrigerant Type R32 R32 R32 R32
Refrigerant Amount g 1,500 2,180 2,180 3,400
Return Air Connection (H x W) 325 x 865 351 x 1062 351 x 1062 351 x 1062
Supply Air Connection (H x W) 295 x 850 304 x 921 304 x 921 304 x 921
UART Communication Yes Yes Yes Yes
UART Communication Port 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75

Source: GENERAL Australia (Fujitsu), High Static Three Phase R32 range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Fujitsu Large Capacity High Static Three Phase

Large capacity R32 three phase ducted models from 18 kW to 22.4 kW cooling for large homes.

Key facts

  • Refrigerant: R32
  • Operation: Reverse Cycle
  • Compatible controller options listed: UTY-RNRT, UTY-ANY2, UTY-RVNYN
Large Capacity High Static Three Phase: models and rated capacities
Model Cooling (kW) Heating (kW)
ARTH65KHTA-3PH 18.00 20.00
ARTH72KHTA-3PH 20.00 22.40
ARTH90KHTA-3PH 22.40 25.00

Cooling and heating figures are rated capacities as published by the manufacturer.

Features listed by the manufacturer

  • Automatic Static Pressure Setting Adjustment
  • All DC
  • Auto Restart
  • Auto Changeover
  • Blue Fin Heat Exchanger
  • Connectable Distributing Duct
  • Connectable Fresh Air Duct
  • Demo Mode
  • Demand Response
  • Economy Mode
  • Filter Sign
  • Program Timer
  • Fresh Air Intake
  • Operating Temperature Range 50°C
  • On-Off Timer
  • Weekly Timer
  • Zone Control

Official Large Capacity High Static Three Phase brochure (GENERAL Australia on Issuu) | Official range page

Specifications: Large Capacity High Static Three Phase (3 models)
Large Capacity High Static Three Phase
Model ARTH65KHTA-3PH ARTH72KHTA-3PH ARTH90KHTA-3PH
Power supply Three phase (3P) Three phase (3P) Three phase (3P)
Operation Type Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50
Capacity Class kW 18 20 22.4
Cooling Capacity kW (Rated (Min - Max)) 18.00 (5.5 - 20) 20.00 (6 - 22.4) 22.40 (6.5 - 26)
Heating Capacity kW (Rated (Min - Max)) 20.00 (5.5 - 22.4) 22.40 (6 - 25) 25.00 (6.5 - 30)
Input Power Cooling kW (Rated (Max)) 5.61 (7.8) 6.16 (7.26) 7.42 (9.9)
Input Power Heating kW (Rated (Max)) 5.24 (6.86) 5.82 (6.63) 6.7 (9.82)
EER Cooling kW/kW 3.21 3.25 3.02
COP Heating kW/kW 3.82 3.85 3.73
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 2.5 / 3 2.5 / 2.5 / 2.5 2 / 2 / 2
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 2.5 / 1.5 3 / 2.5 / 1.5 2.5 / 2 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.532 / 4.343 / 4.585 4.396 / 4.214 / 4.415 3.964 / 3.804 / 3.967
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.503 / 4.001 / 3.446 4.651 / 4.047 / 3.402 4.17 / 3.615 / 3.058
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.842 / 5.006 / 5.389 4.676 / 4.8 / 5.141 4.203 / 4.292 / 4.583
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.503 / 4.192 / 3.732 4.654 / 4.275 / 3.743 4.164 / 3.696 / 3.271
Running Current amps (Cooling / Heating) 8.6 / 8.1 9.9 / 9.5 11.7 / 10.6
Moisture Removal l/hr 4 5.3 4.6
Indoor Sound Pressure Cooling dBA (High / Quiet) 44 / 35 46 / 39 50 / 42
Indoor Sound Pressure Heating dBA (High / Quiet) 44 / 35 46 / 39 50 / 42
Outdoor Sound Pressure dBA (Cooling / Heating) 57 / 58 59 / 61 60 / 62
Outdoor Sound Power dBA 75 76 76
Static Pressure Range PA (Min to Max) 60 to 200 60 to 200 60 to 200
Air Circulation (Indoor - High Fan) Cooling l/sec 1139 1194 1400
Air Circulation (Indoor - High Fan) Heating l/sec 1139 1194 1400
Indoor Unit Dimensions mm (Height x Width x Depth) 360 x 1400 x 850 360 x 1400 x 850 360 x 1400 x 850
Indoor Unit Weight kg 69.00 69.00 79.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 1418 x 970 x 370 1418 x 970 x 370 1418 x 970 x 370
Outdoor Unit Weight kg 102.00 107.00 107.00
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88 12.7 / 19.05 12.7 / 19.05
Pipe Length m (Max (Precharged)) 75 (30) 75 (30) 75 (30)
Max Height Difference m 30 30 30
Operation Range Cooling °CDB (Min to Max) -15 to 50 -15 to 50 -15 to 50
Operation Range Heating °CDB (Min to Max) -20 to 24 -20 to 24 -20 to 24
Refrigerant Type R32 R32 R32
Refrigerant Amount g 3,800 4,500 4,500
Return Air Connection (H x W) 316 x 1295 316 x 1295 316 x 1295
Supply Air Connection (H x W) 277 x 1162 277 x 1162 277 x 1162
UART Communication Yes Yes Yes
UART Communication Port 2 Ports - CN65, CN75 2 Ports - CN65, CN75 2 Ports - CN65, CN75

Source: GENERAL Australia (Fujitsu), Large Capacity High Static Three Phase range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

Fujitsu Bulkhead

Small ducted units for one or two rooms, concealed in a bulkhead or ceiling with only the grilles visible. GENERAL Australia lists these under its single room solutions.

Bulkhead units are concealed in a bulkhead or ceiling space and deliver air to one or two rooms through short duct runs. See our bulkhead air conditioner installation page for how we plan and install them in Melbourne homes.

Key facts

  • Refrigerant: R32
  • Operation: Reverse Cycle
  • Compatible controller options listed: UTY-RNRYZ3
Bulkhead: models and rated capacities
Model Nominal size (kW) Cooling (kW) Heating (kW)
ARTH09KSLAP 2.5 2.50 3.20
ARTH12KSLAP 3.5 3.50 4.00
ARTH18KSLAP 5.0 5.00 6.00

Nominal sizes as listed in the range summary on the official page. Cooling and heating figures are rated capacities as published by the manufacturer.

Features listed by the manufacturer

  • All DC
  • Auto Restart
  • Auto Changeover
  • Blue Fin Heat Exchanger
  • Economy Mode
  • Fresh Air Intake
  • On-Off Timer
  • Removable Intake Grill
  • Weekly + Setback Timer
  • Weekly Timer
  • Automatic Air Flow Adjustment
  • Connectable Distributing Duct

Official Bulkhead brochure (GENERAL Australia on Issuu) | Official range page

Specifications: Bulkhead (3 models)
Bulkhead
Model ARTH09KSLAP ARTH12KSLAP ARTH18KSLAP
Power supply Single phase (1P) Single phase (1P) Single phase (1P)
Operation Type Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
Capacity Class kW 2.5 3.5 5
Cooling Capacity kW (Rated (Min - Max)) 2.50 (0.9 - 3.6) 3.50 (0.9 - 4.1) 5.00 (0.9 - 5.9)
Heating Capacity kW (Rated (Min - Max)) 3.20 (0.9 - 4.5) 4.00 (0.9 - 5.1) 6.00 (0.9 - 7.1)
Input Power Cooling kW (Rated (Max)) 0.64 (1.15) 0.98 (1.41) 1.48 (1.95)
Input Power Heating kW (Rated (Max)) 0.8 (1.5) 1.1 (1.97) 1.73 (2.58)
EER Cooling kW/kW 3.91 3.57 3.38
COP Heating kW/kW 4 3.64 3.47
Star Rating Cooling (0-10) (Hot / Average / Cold) 3 / 2.5 / 3 3 / 2.5 / 2.5 3 / 2.5 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold) 2.5 / 2.5 / 2 2.5 / 2 / 1.5 2.5 / 2 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.999 / 4.49 / 4.551 4.645 / 4.269 / 4.374 4.584 / 4.264 / 4.418
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.339 / 4.053 / 3.736 4.371 / 3.934 / 3.492 4.43 / 3.86 / 3.319
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.371 / 5.359 / 5.663 4.97 / 5.006 / 5.313 4.912 / 5 / 5.339
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.329 / 4.151 / 3.879 4.373 / 4.109 / 3.73 4.439 / 4.094 / 3.628
Running Current amps (Cooling / Heating) 3.2 / 4.1 4.6 / 5.1 6.3 / 7.3
Moisture Removal l/hr 0.5 1.5 2
Indoor Sound Pressure Cooling dBA (High / Quiet) 29 / 23 31 / 23 33 / 23
Indoor Sound Pressure Heating dBA (High / Quiet) 29 / 23 31 / 23 33 / 23
Outdoor Sound Pressure dBA (Cooling / Heating) 41 / 46 47 / 48 48 / 49
Outdoor Sound Power dBA 59 61 62
Static Pressure Range PA (Min to Max) 0 to 30 0 to 30 0 to 50
Air Circulation (Indoor - High Fan) Cooling l/sec 167 181 261
Air Circulation (Indoor - High Fan) Heating l/sec 167 181 261
Indoor Unit Dimensions mm (Height x Width x Depth) 198 x 700 x 450 198 x 700 x 450 198 x 900 x 450
Indoor Unit Weight kg 15.50 15.50 18.50
Outdoor Unit Dimensions mm (Height x Width x Depth) 542 x 799 x 290 542 x 799 x 290 632 x 799 x 290
Outdoor Unit Weight kg 32.00 32.00 36.00
Piping Connects mm Ø (Liquid / Gas) 6.35 / 9.52 6.35 / 9.52 6.35 / 12.7
Pipe Length m (Max (Precharged)) 20 (15) 20 (15) 30 (20)
Max Height Difference m 15 15 20
Operation Range Cooling °CDB (Min to Max) -10 to 46 -10 to 46 -10 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24 -15 to 24 -15 to 24
Refrigerant Type R32 R32 R32
Refrigerant Amount g 850 850 1,020

Source: GENERAL Australia (Fujitsu), Bulkhead range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.

How we install a Fujitsu ducted system in Melbourne

  1. Enquiry and assessment. We discuss the rooms you want to heat and cool, then assess the home, including room sizes, insulation, windows and orientation, and where the indoor and outdoor units can go.
  2. Recommendation and written quote. We recommend a Fujitsu ducted range and capacity that suits the home and explain the options before you commit.
  3. Installation. Our team installs the indoor and outdoor units, runs the refrigerant pipework and condensate drain, and completes the electrical connection as required by Victorian regulations.
  4. Commissioning and handover. We test heating and cooling operation, set up the controller and show you how to use the system and look after the filters.
  5. Ongoing service. Regular maintenance keeps the system running efficiently. See our maintenance services.

Manufacturer warranty

Fujitsu air conditioners in Australia are supplied by GENERAL Australia (formerly Fujitsu General Australia). The company changed its name on 1 January 2026 and continues to market products under the Fujitsu and General Airstage brands (source). Its official website is now generalairstage.com.au.

GENERAL Australia states that it "provides a 5 year full parts and labour warranty for all domestic air conditioning systems sold in Australia" (GENERAL Australia warranty information). Conditions are set out in the manufacturer's warranty card. We register the details of your installation and can assist if a warranty claim is needed.

Victorian Energy Upgrades

EZYAIR is a Victorian Energy Upgrades (VEU) accredited provider (A2261). If you are replacing an older heater with an efficient reverse cycle system, ask us whether your project may be eligible for a VEU discount. Eligibility depends on the existing heater, the new product and the program rules at the time. Learn more on our Victorian Energy Upgrades page.

You can see a range of wall hung, ducted and bulkhead units on display, many of them operational, at our Burwood showroom at 49 Huntingdale Rd, Burwood VIC 3125.

Related pages

Fujitsu ducted air conditioning FAQs

Which Fujitsu ducted range suits a Melbourne home?

It depends on the size of the home, the roof or ceiling space available and whether you have single phase or three phase power. Slimline models suit tight ceiling spaces, while the high static ranges suit larger homes with more outlets. We assess the home before recommending a model.

Can a Fujitsu ducted system be zoned?

Yes. GENERAL Australia lists zone control or zone system compatibility for its current R32 ducted ranges, so you can heat or cool selected areas of the home rather than the whole house.

Do Fujitsu ducted systems heat as well as cool?

Yes. The ducted ranges listed on this page are reverse cycle, so they provide heating in winter and cooling in summer. Published heating capacities for each model are shown in the specification tables.

What warranty applies to Fujitsu ducted air conditioning?

GENERAL Australia states that it provides a 5 year full parts and labour warranty for all domestic air conditioning systems sold in Australia. Conditions are set out in the manufacturer's warranty card.

Can EZYAIR replace my old ducted heater with a Fujitsu ducted system?

Yes. We regularly replace older ducted heating with reverse cycle ducted systems. As a VEU accredited provider (A2261) we can also check whether your project may be eligible for a Victorian Energy Upgrades discount.

What capacities do Fujitsu ducted systems come in?

The Fujitsu ducted and bulkhead ranges on this page are rated from 2.5 kW (Bulkhead) to 22.4 kW cooling (Large Capacity High Static Three Phase), as published by GENERAL Australia. Each range section shows the rated cooling and heating capacity of every model. We calculate the heat load of your home before recommending a size.

Does Fujitsu make a bulkhead ducted unit?

Yes. The Fujitsu Bulkhead range is rated from 2.5 to 5.0 kW cooling, uses R32 refrigerant and has a published indoor unit height of 198 mm. It suits one or two rooms; see our bulkhead air conditioning installation page.

Request a quote

Planning Fujitsu ducted air conditioning for your Melbourne home? Contact EZYAIR or call 1300 EZYAIR (1300 399 247).

You have successfully subscribed!