Fujitsu Ducted Air Conditioning Melbourne
A Fujitsu ducted reverse cycle system heats and cools the whole home from one concealed indoor unit, with air delivered through ducts to discreet ceiling or floor outlets. EZYAIR designs, supplies and installs Fujitsu ducted air conditioning across Melbourne, from apartments and townhouses to large family homes. Request a Fujitsu ducted air conditioning quote or call 1300 EZYAIR (1300 399 247).
Is Fujitsu ducted air conditioning right for your home?
Ducted air conditioning suits Melbourne homes that want consistent comfort through cold winters and hot summers without wall mounted units in every room. A ducted system needs space for the indoor unit in the roof, ceiling or under the floor, and a suitable location for the outdoor unit. With zoning, you can choose which areas are heated or cooled. If you only need to condition one or two rooms, a Fujitsu split system or a Fujitsu multi split system may be a better fit.
Current Fujitsu ducted ranges
The following reverse cycle ducted ranges (up to 25kW) and bulkhead units are listed on the official GENERAL Australia website at the time of writing (October 2026) and are the Fujitsu ducted systems we supply and install. Select a range to jump to its details.
- Fujitsu High Static Single Phase R32
- Fujitsu High Static Single Phase R32 (HP)
- Fujitsu Large Capacity High Static Single Phase
- Fujitsu Mid Static Slimline R32
- Fujitsu Mid Static Slimline R32 (HP)
- Fujitsu High Static Three Phase R32
- Fujitsu Large Capacity High Static Three Phase
- Fujitsu Bulkhead
EZYAIR is an independent air conditioning installer. Product information on this page is copied from the official GENERAL Australia (Fujitsu) website and brochures. Figures are as published by the manufacturer. Where a figure is not published it is not shown. Tables scroll sideways on smaller screens.
Fujitsu High Static Single Phase R32
A whole home range of six single phase models from 7.1 kW to 15.5 kW cooling. The manufacturer states a guaranteed operating range of up to 50°C in cooling, demand response capability and zone system compatibility.
Key facts
- Refrigerant: R32
- Operation: Reverse Cycle
- Compatible controller options listed: UTY-RVNYN
| Model | Cooling (kW) | Heating (kW) |
|---|---|---|
| ARTH24KHTA | 7.10 | 8.00 |
| ARTH30KHTA | 8.50 | 10.00 |
| ARTH36KHTA | 10.00 | 11.20 |
| ARTH45KHTA | 12.50 | 14.00 |
| ARTH54KHTA | 14.00 | 15.50 |
| ARTH60KHTA | 15.50 | 18.00 |
Cooling and heating figures are rated capacities as published by the manufacturer.
Features listed by the manufacturer
- Zone Control
- Auto Restart
- Auto Changeover
- Blue Fin Heat Exchanger
- Connectable Distributing Duct
- Connectable Fresh Air Duct
- Demand Response
- All DC
- Economy Mode
- Filter Sign
- On-Off Timer
- Program Timer
- Weekly Timer
- Operating Temperature Range 50°C
- Demo Mode
- Automatic Static Pressure Setting Adjustment
Official High Static Single Phase R32 brochure (GENERAL Australia on Issuu) | Official range page
Specifications: High Static Single Phase R32 (6 models)
| Model | ARTH24KHTA | ARTH30KHTA | ARTH36KHTA | ARTH45KHTA | ARTH54KHTA | ARTH60KHTA |
|---|---|---|---|---|---|---|
| Power supply | Single phase (1P) | Single phase (1P) | Single phase (1P) | Single phase (1P) | Single phase (1P) | Single phase (1P) |
| Operation Type | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
| Cooling Capacity kW (Rated (Min - Max)) | 7.10 (1.8 - 8.1) | 8.50 (2.8 - 10.3) | 10.00 (2.8 - 11.4) | 12.50 (4 - 14) | 14.00 (4.5 - 15) | 15.50 (5 - 16.5) |
| Heating Capacity kW (Rated (Min - Max)) | 8.00 (2 - 9.1) | 10.00 (2.7 - 11.3) | 11.20 (2.7 - 14) | 14.00 (4.2 - 16.5) | 15.50 (4.7 - 18) | 18.00 (5.1 - 19) |
| Input Power Cooling kW (Rated (Max)) | 2.14 (2.53) | 2.35 (3.47) | 3.08 (4.01) | 3.8 (5.16) | 4.64 (5.17) | 4.94 (6.02) |
| Input Power Heating kW (Rated (Max)) | 2.05 (2.45) | 2.35 (4.12) | 2.8 (4.21) | 3.42 (5.22) | 4.4 (5.23) | 4.89 (6.74) |
| EER Cooling kW/kW | 3.32 | 3.62 | 3.25 | 3.29 | 3.02 | 3.14 |
| COP Heating kW/kW | 3.9 | 4.26 | 4 | 4.09 | 3.52 | 3.68 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 3 / 3 / 3 | 3 / 2.5 / 3 | 3 / 2.5 / 3 | 3 / 2.5 / 3 | 2.5 / 2.5 / 2.5 | 2.5 / 2.5 / 2.5 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3 / 2.5 / 1.5 | 3 / 2.5 / 2 | 3 / 2.5 / 1.5 | 3 / 2.5 / 2 | 3 / 2 / 1.5 | 2.5 / 2 / 1.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.912 / 4.611 / 4.875 | 4.695 / 4.469 / 4.637 | 4.642 / 4.426 / 4.675 | 4.612 / 4.403 / 4.635 | 4.339 / 4.147 / 4.39 | 4.378 / 4.193 / 4.416 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.825 / 4.11 / 3.444 | 4.61 / 4.211 / 3.654 | 4.72 / 4.073 / 3.429 | 4.766 / 4.208 / 3.574 | 4.691 / 3.937 / 3.306 | 4.487 / 3.885 / 3.31 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 5.299 / 5.489 / 5.931 | 4.982 / 5.065 / 5.397 | 4.972 / 5.144 / 5.544 | 4.928 / 5.083 / 5.465 | 4.647 / 4.816 / 5.195 | 4.673 / 4.821 / 5.181 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.831 / 4.41 / 3.707 | 4.6 / 4.35 / 3.895 | 4.72 / 4.34 / 3.67 | 4.764 / 4.41 / 3.901 | 4.706 / 4.101 / 3.573 | 4.491 / 4.135 / 3.523 |
| Running Current amps (Cooling / Heating) | 9.4 / 9 | 10.4 / 10.4 | 13.6 / 12.3 | 16.7 / 15 | 20.4 / 19.3 | 21.7 / 21.4 |
| Moisture Removal l/hr | 0.5 | 0.1 | 1.4 | 0.9 | 1.6 | 2.8 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 34 / 27 | 41 / 36 | 41 / 36 | 43 / 35 | 45 / 36 | 45 / 36 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 34 / 27 | 41 / 36 | 41 / 36 | 43 / 35 | 45 / 36 | 45 / 36 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 48 / 50 | 51 / 53 | 53 / 53 | 55 / 57 | 55 / 57 | 53 / 55 |
| Outdoor Sound Power dBA | 68 | 69 | 70 | 71 | 72 | 71 |
| Static Pressure Range PA (Min to Max) | 60 to 210 | 60 to 210 | 60 to 210 | 60 to 260 | 60 to 260 | 60 to 260 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 500 | 695 | 695 | 903 | 986 | 986 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 500 | 695 | 695 | 903 | 986 | 986 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 400 x 1050 x 500 | 400 x 1050 x 500 | 400 x 1050 x 500 | 425 x 1250 x 490 | 425 x 1250 x 490 | 425 x 1250 x 490 |
| Indoor Unit Weight kg | 38.00 | 39.00 | 39.00 | 53.00 | 53.00 | 53.00 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 716 x 820 x 315 | 788 x 940 x 320 | 788 x 940 x 320 | 998 x 940 x 320 | 998 x 940 x 320 | 1418 x 970 x 370 |
| Outdoor Unit Weight kg | 42.00 | 52.00 | 52.00 | 67.00 | 67.00 | 95.00 |
| Piping Connects mm Ø (Liquid / Gas) | 6.35 / 12.7 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 |
| Pipe Length m (Max (Precharged)) | 30 (20) | 50 (30) | 50 (30) | 50 (30) | 50 (30) | 50 (30) |
| Max Height Difference m | 25 | 30 | 30 | 30 | 30 | 30 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 |
| Refrigerant Type | R32 | R32 | R32 | R32 | R32 | R32 |
| Refrigerant Amount g | 1,250 | 1,900 | 1,900 | 2,700 | 2,700 | 2,550 |
| Return Air Connection (H x W) | 325 x 865 | 325 x 865 | 325 x 865 | 351 x 1062 | 351 x 1062 | 351 x 1062 |
| Supply Air Connection (H x W) | 295 x 850 | 295 x 850 | 295 x 850 | 304 x 921 | 304 x 921 | 304 x 921 |
| UART Communication | Yes | Yes | Yes | Yes | Yes | Yes |
| UART Communication Port | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 |
Source: GENERAL Australia (Fujitsu), High Static Single Phase R32 range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu High Static Single Phase R32 (HP)
The high performance version of the High Static Single Phase R32 range, with five models from 8.5 kW to 16 kW cooling, also zone system compatible.
Key facts
- Refrigerant: R32
- Operation: Reverse Cycle
- Compatible controller options listed: UTY-RNRT
| Model | Cooling (kW) | Heating (kW) |
|---|---|---|
| ARTH30KHTA-HP | 8.50 | 10.00 |
| ARTH36KHTA-HP | 10.00 | 12.50 |
| ARTH45KHTA-HP | 12.50 | 15.00 |
| ARTH54KHTA-HP | 14.00 | 16.50 |
| ARTH60KHTB | 16.00 | 18.00 |
Cooling and heating figures are rated capacities as published by the manufacturer.
Features listed by the manufacturer
- Zone Control
- Auto Restart
- Auto Changeover
- Blue Fin Heat Exchanger
- Connectable Distributing Duct
- Connectable Fresh Air Duct
- Demand Response
- Economy Mode
- Filter Sign
- On-Off Timer
- Program Timer
- Weekly Timer
- Operating Temperature Range 50°C
- Demo Mode
- Automatic Static Pressure Setting Adjustment
- All DC
- Long Piping Capability 75m
Official High Static Single Phase R32 (HP) brochure (GENERAL Australia on Issuu) | Official range page
Specifications: High Static Single Phase R32 (HP) (5 models)
| Model | ARTH30KHTA-HP | ARTH36KHTA-HP | ARTH45KHTA-HP | ARTH54KHTA-HP | ARTH60KHTB |
|---|---|---|---|---|---|
| Power supply | Single phase (1P) | Single phase (1P) | Single phase (1P) | Single phase (1P) | Single phase (1P) |
| Operation Type | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
| Cooling Capacity kW (Rated (Min - Max)) | 8.50 (4.1 - 11) | 10.00 (5 - 13) | 12.50 (5.6 - 14.5) | 14.00 (6.3 - 16.5) | 16.00 (7.4 - 17.5) |
| Heating Capacity kW (Rated (Min - Max)) | 10.00 (4.2 - 12) | 12.50 (5.2 - 15) | 15.00 (5.2 - 17) | 16.50 (5.8 - 18.5) | 18.00 (7.4 - 20.5) |
| Input Power Cooling kW (Rated (Max)) | 2.18 (3.36) | 2.6 (5.01) | 3.43 (4.39) | 3.91 (5.35) | 4.82 (5.31) |
| Input Power Heating kW (Rated (Max)) | 2.2 (3.12) | 2.94 (4.65) | 3.49 (4.46) | 4 (4.49) | 4.63 (5.19) |
| EER Cooling kW/kW | 3.9 | 3.85 | 3.61 | 3.58 | 3.32 |
| COP Heating kW/kW | 4.55 | 4.25 | 4.3 | 4.13 | 3.89 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 3 / 3 / 3 | 3 / 3 / 3 | 3 / 3 / 3 | 3 / 2.5 / 3 | 3 / 2.5 / 3 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3 / 3 / 2 | 3 / 2.5 / 2 | 3 / 2.5 / 2 | 2.5 / 2.5 / 2 | 3 / 2.5 / 1.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.833 / 4.593 / 4.727 | 4.964 / 4.727 / 4.9 | 4.785 / 4.573 / 4.76 | 4.666 / 4.464 / 4.642 | 4.533 / 4.342 / 4.555 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.856 / 4.509 / 3.994 | 4.912 / 4.377 / 3.733 | 4.702 / 4.305 / 3.753 | 4.4 / 4.028 / 3.502 | 4.521 / 4.001 / 3.428 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 5.108 / 5.148 / 5.458 | 5.264 / 5.347 / 5.694 | 5.079 / 5.18 / 5.528 | 4.947 / 5.04 / 5.375 | 4.828 / 4.962 / 5.32 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.843 / 4.624 / 4.201 | 4.909 / 4.58 / 4.043 | 4.693 / 4.446 / 3.992 | 4.388 / 4.154 / 3.729 | 4.519 / 4.195 / 3.734 |
| Running Current amps (Cooling / Heating) | 9.6 / 9.7 | 11.4 / 12.9 | 15.1 / 15.3 | 17.2 / 17.5 | 21.1 / 20.3 |
| Moisture Removal l/hr | 0.1 | 1.4 | 0.9 | 1.6 | 3.4 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 41 / 36 | 41 / 36 | 43 / 35 | 45 / 36 | 44 / 39 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 41 / 36 | 41 / 36 | 43 / 35 | 45 / 36 | 44 / 39 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 51 / 53 | 53 / 53 | 53 / 53 | 53 / 55 | 53 / 55 |
| Outdoor Sound Power dBA | 69 | 70 | 70 | 71 | 71 |
| Static Pressure Range PA (Min to Max) | 60 to 210 | 60 to 210 | 60 to 260 | 60 to 260 | 60 to 250 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 695 | 695 | 903 | 986 | 1139 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 695 | 695 | 903 | 986 | 1139 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 400 x 1050 x 500 | 400 x 1050 x 500 | 425 x 1250 x 490 | 425 x 1250 x 490 | 360 x 1400 x 850 |
| Indoor Unit Weight kg | 39.00 | 39.00 | 53.00 | 53.00 | 69.00 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 998 x 940 x 320 | 998 x 940 x 320 | 1418 x 970 x 370 | 1418 x 970 x 370 | 1418 x 970 x 370 |
| Outdoor Unit Weight kg | 64.00 | 67.00 | 95.00 | 101.00 | 101.00 |
| Piping Connects mm Ø (Liquid / Gas) | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 |
| Pipe Length m (Max (Precharged)) | 75 (30) | 75 (30) | 75 (30) | 75 (30) | 75 (30) |
| Max Height Difference m | 30 | 30 | 30 | 30 | 30 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 |
| Refrigerant Type | R32 | R32 | R32 | R32 | R32 |
| Refrigerant Amount g | 2,100 | 2,500 | 3,400 | 3,800 | 3,800 |
| Return Air Connection (H x W) | 325 x 865 | 325 x 865 | 351 x 1062 | 351 x 1062 | 316 x 1295 |
| Supply Air Connection (H x W) | 295 x 850 | 295 x 850 | 304 x 921 | 304 x 921 | 277 x 1162 |
| UART Communication | Yes | Yes | Yes | Yes | Yes |
| UART Communication Port | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 |
Source: GENERAL Australia (Fujitsu), High Static Single Phase R32 (HP) range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu Large Capacity High Static Single Phase
A large capacity single phase ducted model for bigger homes. The manufacturer notes touch panel and Wi-Fi control options.
Key facts
- Refrigerant: R32
- Operation: Reverse Cycle
- Compatible controller options listed: UTY-RNRT
| Model | Cooling (kW) | Heating (kW) |
|---|---|---|
| ARTH65KHTA | 18.00 | 20.00 |
Cooling and heating figures are rated capacities as published by the manufacturer.
Features listed by the manufacturer
- Automatic Static Pressure Setting Adjustment
- All DC
- Auto Restart
- Auto Changeover
- Blue Fin Heat Exchanger
- Connectable Distributing Duct
- Connectable Fresh Air Duct
- Demo Mode
- Demand Response
- Economy Mode
- Filter Sign
- Program Timer
- Fresh Air Intake
- Operating Temperature Range 50°C
- On-Off Timer
- Weekly Timer
- Zone Control
Official Large Capacity High Static Single Phase brochure (GENERAL Australia on Issuu) | Official range page
Specifications: Large Capacity High Static Single Phase (1 models)
| Model | ARTH65KHTA |
|---|---|
| Power supply | Single phase (1P) |
| Operation Type | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 |
| Capacity Class kW | 18 |
| Cooling Capacity kW (Rated (Min - Max)) | 18.00 (5.5 - 20) |
| Heating Capacity kW (Rated (Min - Max)) | 20.00 (5.5 - 22.4) |
| Input Power Cooling kW (Rated (Max)) | 5.61 (7.8) |
| Input Power Heating kW (Rated (Max)) | 5.24 (6.86) |
| EER Cooling kW/kW | 3.21 |
| COP Heating kW/kW | 3.82 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 3 / 2.5 / 3 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3 / 2.5 / 1.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.532 / 4.343 / 4.585 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.503 / 4.001 / 3.446 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.842 / 5.006 / 5.389 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.503 / 4.192 / 3.732 |
| Running Current amps (Cooling / Heating) | 24.6 / 23 |
| Moisture Removal l/hr | 4 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 44 / 35 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 44 / 35 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 57 / 58 |
| Outdoor Sound Power dBA | 74 |
| Static Pressure Range PA (Min to Max) | 60 to 200 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 1139 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 1139 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 360 x 1400 x 850 |
| Indoor Unit Weight kg | 69.00 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 1418 x 970 x 370 |
| Outdoor Unit Weight kg | 101.00 |
| Piping Connects mm Ø (Liquid / Gas) | 9.52 / 15.88 |
| Pipe Length m (Max (Precharged)) | 75 (30) |
| Max Height Difference m | 30 |
| Operation Range Cooling °CDB (Min to Max) | -15 to 50 |
| Operation Range Heating °CDB (Min to Max) | -20 to 24 |
| Refrigerant Type | R32 |
| Refrigerant Amount g | 3,800 |
Source: GENERAL Australia (Fujitsu), Large Capacity High Static Single Phase range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu Mid Static Slimline R32
Slimline ducted units with an indoor unit 240 mm high and a built in drain pump, designed for tighter bulkhead and ceiling spaces such as apartments, townhouses and single storey homes with limited roof space.
Key facts
- Refrigerant: R32
- Operation: Reverse Cycle
| Model | Cooling (kW) | Heating (kW) |
|---|---|---|
| ARTH18KMTAP | 5.00 | 6.00 |
| ARTH24KMTAP | 7.10 | 8.00 |
| ARTH30KMTAP | 8.50 | 10.00 |
| ARTH36KMTAP | 10.00 | 11.20 |
| ARTH45KMTAP | 12.50 | 14.00 |
| ARTH54KMTAP | 13.00 | 15.00 |
Cooling and heating figures are rated capacities as published by the manufacturer.
Features listed by the manufacturer
- In-Built Safety Tray
- Program Timer
- Economy Mode
- Zone Control
- Auto Restart
- Auto Changeover
- Blue Fin Heat Exchanger
- Connectable Fresh Air Duct
- Connectable Distributing Duct
- Demand Response
- Filter Sign
- On-Off Timer
- Weekly Timer
- Operating Temperature Range 50°C
- Demo Mode
Official Mid Static Slimline R32 brochure (GENERAL Australia on Issuu) | Official range page
Specifications: Mid Static Slimline R32 (6 models)
| Model | ARTH18KMTAP | ARTH24KMTAP | ARTH30KMTAP | ARTH36KMTAP | ARTH45KMTAP | ARTH54KMTAP |
|---|---|---|---|---|---|---|
| Power supply | Single phase (1P) | Single phase (1P) | Single phase (1P) | Single phase (1P) | Single phase (1P) | Single phase (1P) |
| Operation Type | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
| Cooling Capacity kW (Rated (Min - Max)) | 5.00 (0.9 - 6.4) | 7.10 (1.8 - 8.1) | 8.50 (2.8 - 10.3) | 10.00 (2.8 - 11.4) | 12.50 (4 - 14) | 13.00 (4.5 - 15) |
| Heating Capacity kW (Rated (Min - Max)) | 6.00 (0.9 - 7.8) | 8.00 (2 - 9.1) | 10.00 (2.7 - 11.3) | 11.20 (2.7 - 14) | 14.00 (4.2 - 16.5) | 15.00 (4.7 - 18) |
| Input Power Cooling kW (Rated (Max)) | 1.37 (1.95) | 2.15 (2.92) | 2.6 (4.28) | 3.23 (4.3) | 4 (5.18) | 4.31 (5.19) |
| Input Power Heating kW (Rated (Max)) | 1.58 (2.39) | 2.19 (2.67) | 2.62 (4.44) | 3.3 (4.5) | 4 (5.22) | 4.45 (5.23) |
| EER Cooling kW/kW | 3.65 | 3.3 | 3.5461 | 3.1914 | 3.13 | 3.02 |
| COP Heating kW/kW | 3.8 | 3.65 | 4.1151 | 3.7299 | 3.5 | 3.37 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 3 / 2.5 / 2 | 3 / 2 / 1.5 | 2.5 / 2.5 / 2.5 | 2.5 / 2.5 / 2.5 | 3 / 2 / 1.5 | 2.5 / 2 / 1.5 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3.5 / 3 / 3 | 3 / 2.5 / 2.5 | 3 / 2.5 / 2 | 3 / 2 / 1.5 | 2.5 / 2.5 / 3 | 2.5 / 2.5 / 2.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 5.012 / 4.663 / 4.844 | 4.558 / 4.294 / 4.484 | 4.781 / 4.91 / 5.264 | 4.338 / 4.141 / 4.359 | 4.462 / 4.265 / 4.509 | 4.354 / 4.163 / 4.412 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.74 / 4.182 / 3.616 | 4.694 / 3.996 / 3.375 | 5.036 / 4.472 / 3.899 | 4.568 / 3.815 / 3.201 | 4.512 / 3.881 / 3.295 | 4.371 / 3.688 / 3.113 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 5.377 / 5.485 / 5.866 | 4.878 / 4.999 / 5.356 | 4.781 / 4.91 / 5.264 | 4.635 / 4.781 / 5.14 | 4.775 / 4.943 / 5.327 | 4.664 / 4.837 / 5.221 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.747 / 4.409 / 3.923 | 4.704 / 4.291 / 3.622 | 4.731 / 4.361 / 3.834 | 4.583 / 4.139 / 3.467 | 4.522 / 4.129 / 3.641 | 4.382 / 3.98 / 3.356 |
| Running Current amps (Cooling / Heating) | 5.9 / 6.8 | 9.1 / 9.2 | 11 / 11.2 | 13.6 / 13.9 | 16.8 / 16.8 | 18.1 / 18.7 |
| Moisture Removal l/hr | 1.3 | 1.7 | 1.6 | 2.9 | 4.5 | 5 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 33 / 23 | 38 / 27 | 38 / 28 | 38 / 27 | 40 / 29 | 40 / 29 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 33 / 23 | 38 / 27 | 38 / 28 | 38 / 27 | 40 / 29 | 40 / 29 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 48 / 49 | 48 / 50 | 51 / 53 | 53 / 53 | 55 / 57 | 55 / 57 |
| Outdoor Sound Power dBA | 62 | 68 | 69 | 70 | 71 | 72 |
| Static Pressure Range PA (Min to Max) | 50 to 150 | 50 to 150 | 50 to 150 | 50 to 150 | 50 to 150 | 50 to 150 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 300 | 416.67 | 541.67 | 575 | 600 | 600 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 300 | 416.67 | 541.67 | 575 | 600 | 600 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 240 x 1000 x 700 | 240 x 1000 x 700 | 240 x 1400 x 700 | 240 x 1400 x 700 | 240 x 1400 x 700 | 240 x 1400 x 700 |
| Indoor Unit Weight kg | 31.00 | 31.00 | 42.00 | 42.00 | 42.00 | 42.00 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 632 x 799 x 290 | 716 x 820 x 315 | 788 x 940 x 320 | 788 x 940 x 320 | 998 x 940 x 320 | 998 x 940 x 320 |
| Outdoor Unit Weight kg | 36.00 | 42.00 | 52.00 | 52.00 | 67.00 | 67.00 |
| Piping Connects mm Ø (Liquid / Gas) | 6.35 / 12.7 | 6.35 / 12.7 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 |
| Pipe Length m (Max (Precharged)) | 30 (20) | 30 (20) | 50 (30) | 50 (30) | 50 (30) | 50 (30) |
| Max Height Difference m | 20 | 25 | 30 | 30 | 30 | 30 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 |
| Refrigerant Type | R32 | R32 | R32 | R32 | R32 | R32 |
| Refrigerant Amount g | 1,020 | 1,250 | 1,900 | 1,900 | 2,700 | 2,700 |
| Return Air Connection (H x W) | 195 x 895 | 195 x 895 | 195 x 1295 | 195 x 1295 | 195 x 1295 | 195 x 1295 |
| Supply Air Connection (H x W) | 177 x 790 | 177 x 790 | 177 x 1190 | 177 x 1190 | 177 x 1190 | 177 x 1190 |
| UART Communication | Yes | Yes | Yes | Yes | Yes | Yes |
| UART Communication Port | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 |
Source: GENERAL Australia (Fujitsu), Mid Static Slimline R32 range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu Mid Static Slimline R32 (HP)
A high performance version of the Mid Static Slimline R32. The manufacturer quotes a maximum pipe length of 75 m, making these models suited to installations where the outdoor unit is on a roof or in a plant room of an apartment building.
Key facts
- Refrigerant: R32
- Operation: Reverse Cycle
| Model | Cooling (kW) | Heating (kW) |
|---|---|---|
| ARTH24KMTAP-HP | 7.10 | 8.00 |
| ARTH30KMTAP-HP | 8.50 | 10.00 |
Cooling and heating figures are rated capacities as published by the manufacturer.
Features listed by the manufacturer
- Zone Control
- Auto Restart
- Auto Changeover
- Blue Fin Heat Exchanger
- Connectable Distributing Duct
- Connectable Fresh Air Duct
- Demand Response
- Economy Mode
- Filter Sign
- On-Off Timer
- Program Timer
- Weekly Timer
- In-Built Drain Pump
- Operating Temperature Range 50°C
- Demo Mode
- Long Piping Capability 75m
Official Mid Static Slimline R32 (HP) brochure (GENERAL Australia on Issuu) | Official range page
Specifications: Mid Static Slimline R32 (HP) (2 models)
| Model | ARTH24KMTAP-HP | ARTH30KMTAP-HP |
|---|---|---|
| Power supply | Single phase (1P) | Single phase (1P) |
| Operation Type | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 | 230 / 1 / 50 |
| Cooling Capacity kW (Rated (Min - Max)) | 7.10 (3.3 - 8.5) | 8.50 (4.1 - 10.5) |
| Heating Capacity kW (Rated (Min - Max)) | 8.00 (3.6 - 10.5) | 10.00 (4.2 - 11.5) |
| Input Power Cooling kW (Rated (Max)) | 1.85 (2.72) | 2.26 (3.38) |
| Input Power Heating kW (Rated (Max)) | 1.93 (2.89) | 2.47 (3.12) |
| EER Cooling kW/kW | 3.84 | 3.76 |
| COP Heating kW/kW | 4.15 | 4.05 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 3 / 2.5 / 2.5 | 3.5 / 2.5 / 2 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3 / 2.5 / 3 | 3 / 3 / 3 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.712 / 4.474 / 4.598 | 4.8 / 4.569 / 4.727 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.962 / 4.491 / 4.043 | 5.036 / 4.472 / 3.899 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.976 / 5.005 / 5.302 | 5.084 / 5.154 / 5.481 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.964 / 4.288 / 4.679 | 5.043 / 4.702 / 4.207 |
| Running Current amps (Cooling / Heating) | 8 / 8.4 | 9.6 / 10.5 |
| Moisture Removal l/hr | 1.7 | 1.6 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 38 / 27 | 38 / 28 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 38 / 27 | 38 / 28 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 48 / 50 | 51 / 53 |
| Outdoor Sound Power dBA | 67 | 69 |
| Static Pressure Range PA (Min to Max) | 50 to 150 | 50 to 150 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 416.67 | 541.67 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 416.67 | 541.67 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 240 x 1000 x 700 | 240 x 1400 x 700 |
| Indoor Unit Weight kg | 31.00 | 42.00 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 988 x 940 x 320 | 998 x 940 x 320 |
| Outdoor Unit Weight kg | 63.00 | 64.00 |
| Piping Connects mm Ø (Liquid / Gas) | 6.35 / 12.7 | 9.52 / 15.88 |
| Pipe Length m (Max (Precharged)) | 75 (30) | 75 (30) |
| Max Height Difference m | 30 | 30 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 50 | -10 to 50 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 | -15 to 24 |
| Refrigerant Type | R32 | R32 |
| Refrigerant Amount g | 1,800 | 2,100 |
| Return Air Connection (H x W) | 195 x 895 | 195 x 1295 |
| Supply Air Connection (H x W) | 177 x 790 | 177 x 1190 |
| UART Communication | Yes | Yes |
| UART Communication Port | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 |
Source: GENERAL Australia (Fujitsu), Mid Static Slimline R32 (HP) range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu High Static Three Phase R32
Four three phase models from 10 kW to 15.5 kW cooling for larger houses with a three phase supply, with demand response and zone system compatibility.
Key facts
- Refrigerant: R32
- Operation: Reverse Cycle
- Compatible controller options listed: UTY-RVNYN
| Model | Cooling (kW) | Heating (kW) |
|---|---|---|
| ARTH36KHTA-3PH | 10.00 | 11.20 |
| ARTH45KHTA-3PH | 12.50 | 14.00 |
| ARTH54KHTA-3PH | 14.00 | 15.50 |
| ARTH60KHTA-3PH | 15.50 | 18.00 |
Cooling and heating figures are rated capacities as published by the manufacturer.
Features listed by the manufacturer
- Automatic Static Pressure Setting Adjustment
- All DC
- Auto Restart
- Auto Changeover
- Blue Fin Heat Exchanger
- Connectable Distributing Duct
- Connectable Fresh Air Duct
- Demo Mode
- Demand Response
- Economy Mode
- Filter Sign
- Program Timer
- Fresh Air Intake
- Operating Temperature Range 50°C
- On-Off Timer
- Weekly Timer
- Zone Control
Official High Static Three Phase R32 brochure (GENERAL Australia on Issuu) | Official range page
Specifications: High Static Three Phase R32 (4 models)
| Model | ARTH36KHTA-3PH | ARTH45KHTA-3PH | ARTH54KHTA-3PH | ARTH60KHTA-3PH |
|---|---|---|---|---|
| Power supply | Three phase (3P) | Three phase (3P) | Three phase (3P) | Three phase (3P) |
| Operation Type | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 400 / 3 / 50 | 400 / 3 / 50 | 400 / 3 / 50 | 400 / 3 / 50 |
| Cooling Capacity kW (Rated (Min - Max)) | 10.00 (2.8 - 11.4) | 12.50 (4 - 14) | 14.00 (4.5 - 15) | 15.50 (5 - 16.5) |
| Heating Capacity kW (Rated (Min - Max)) | 11.20 (2.7 - 14) | 14.00 (4.2 - 16.5) | 15.50 (4.7 - 18) | 18.00 (5.1 - 19) |
| Input Power Cooling kW (Rated (Max)) | 3.08 (4.01) | 3.8 (5.16) | 4.64 (5.17) | 4.94 (6.02) |
| Input Power Heating kW (Rated (Max)) | 2.8 (4.21) | 3.42 (5.22) | 4.4 (5.23) | 4.89 (6.74) |
| EER Cooling kW/kW | 3.25 | 3.29 | 3.02 | 3.14 |
| COP Heating kW/kW | 4 | 4.09 | 3.52 | 3.68 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 3 / 2.5 / 3 | 3 / 2.5 / 3 | 2.5 / 2.5 / 2.5 | 2.5 / 2.5 / 2.5 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3 / 2.5 / 1.5 | 3 / 2.5 / 2 | 3 / 2 / 1.5 | 2.5 / 2 / 1.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.642 / 4.426 / 4.675 | 4.612 / 4.403 / 4.635 | 4.339 / 4.147 / 4.39 | 4.378 / 4.193 / 4.416 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.72 / 4.073 / 3.429 | 4.766 / 4.208 / 3.574 | 4.691 / 3.937 / 3.306 | 4.487 / 3.885 / 3.31 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.972 / 5.144 / 5.544 | 4.928 / 5.083 / 5.465 | 4.647 / 4.816 / 5.195 | 4.673 / 4.821 / 5.181 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.72 / 4.34 / 3.67 | 4.764 / 4.41 / 3.901 | 4.706 / 4.101 / 3.573 | 4.491 / 4.135 / 3.523 |
| Running Current amps (Cooling / Heating) | 5.2 / 4.7 | 6.4 / 5.7 | 7.7 / 7 | 7.8 / 7.9 |
| Moisture Removal l/hr | 1.4 | 0.9 | 1.6 | 2.8 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 41 / 36 | 43 / 35 | 45 / 36 | 45 / 36 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 41 / 36 | 43 / 35 | 45 / 36 | 45 / 36 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 53 / 53 | 55 / 57 | 55 / 57 | 53 / 55 |
| Outdoor Sound Power dBA | 70 | 71 | 72 | 71 |
| Static Pressure Range PA (Min to Max) | 60 to 210 | 60 to 260 | 60 to 260 | 60 to 260 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 695 | 903 | 986 | 986 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 695 | 903 | 986 | 986 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 400 x 1050 x 500 | 425 x 1250 x 490 | 425 x 1250 x 490 | 425 x 1250 x 490 |
| Indoor Unit Weight kg | 39.00 | 53.00 | 53.00 | 53.00 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 788 x 940 x 320 | 998 x 940 x 320 | 998 x 940 x 320 | 1418 x 970 x 370 |
| Outdoor Unit Weight kg | 53.00 | 67.00 | 67.00 | 96.00 |
| Piping Connects mm Ø (Liquid / Gas) | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 |
| Pipe Length m (Max (Precharged)) | 50 (30) | 50 (30) | 50 (30) | 50 (30) |
| Max Height Difference m | 30 | 30 | 30 | 30 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 |
| Refrigerant Type | R32 | R32 | R32 | R32 |
| Refrigerant Amount g | 1,500 | 2,180 | 2,180 | 3,400 |
| Return Air Connection (H x W) | 325 x 865 | 351 x 1062 | 351 x 1062 | 351 x 1062 |
| Supply Air Connection (H x W) | 295 x 850 | 304 x 921 | 304 x 921 | 304 x 921 |
| UART Communication | Yes | Yes | Yes | Yes |
| UART Communication Port | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 |
Source: GENERAL Australia (Fujitsu), High Static Three Phase R32 range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu Large Capacity High Static Three Phase
Large capacity R32 three phase ducted models from 18 kW to 22.4 kW cooling for large homes.
Key facts
- Refrigerant: R32
- Operation: Reverse Cycle
- Compatible controller options listed: UTY-RNRT, UTY-ANY2, UTY-RVNYN
| Model | Cooling (kW) | Heating (kW) |
|---|---|---|
| ARTH65KHTA-3PH | 18.00 | 20.00 |
| ARTH72KHTA-3PH | 20.00 | 22.40 |
| ARTH90KHTA-3PH | 22.40 | 25.00 |
Cooling and heating figures are rated capacities as published by the manufacturer.
Features listed by the manufacturer
- Automatic Static Pressure Setting Adjustment
- All DC
- Auto Restart
- Auto Changeover
- Blue Fin Heat Exchanger
- Connectable Distributing Duct
- Connectable Fresh Air Duct
- Demo Mode
- Demand Response
- Economy Mode
- Filter Sign
- Program Timer
- Fresh Air Intake
- Operating Temperature Range 50°C
- On-Off Timer
- Weekly Timer
- Zone Control
Official Large Capacity High Static Three Phase brochure (GENERAL Australia on Issuu) | Official range page
Specifications: Large Capacity High Static Three Phase (3 models)
| Model | ARTH65KHTA-3PH | ARTH72KHTA-3PH | ARTH90KHTA-3PH |
|---|---|---|---|
| Power supply | Three phase (3P) | Three phase (3P) | Three phase (3P) |
| Operation Type | Reverse Cycle | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 400 / 3 / 50 | 400 / 3 / 50 | 400 / 3 / 50 |
| Capacity Class kW | 18 | 20 | 22.4 |
| Cooling Capacity kW (Rated (Min - Max)) | 18.00 (5.5 - 20) | 20.00 (6 - 22.4) | 22.40 (6.5 - 26) |
| Heating Capacity kW (Rated (Min - Max)) | 20.00 (5.5 - 22.4) | 22.40 (6 - 25) | 25.00 (6.5 - 30) |
| Input Power Cooling kW (Rated (Max)) | 5.61 (7.8) | 6.16 (7.26) | 7.42 (9.9) |
| Input Power Heating kW (Rated (Max)) | 5.24 (6.86) | 5.82 (6.63) | 6.7 (9.82) |
| EER Cooling kW/kW | 3.21 | 3.25 | 3.02 |
| COP Heating kW/kW | 3.82 | 3.85 | 3.73 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 3 / 2.5 / 3 | 2.5 / 2.5 / 2.5 | 2 / 2 / 2 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3 / 2.5 / 1.5 | 3 / 2.5 / 1.5 | 2.5 / 2 / 1.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.532 / 4.343 / 4.585 | 4.396 / 4.214 / 4.415 | 3.964 / 3.804 / 3.967 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.503 / 4.001 / 3.446 | 4.651 / 4.047 / 3.402 | 4.17 / 3.615 / 3.058 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.842 / 5.006 / 5.389 | 4.676 / 4.8 / 5.141 | 4.203 / 4.292 / 4.583 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.503 / 4.192 / 3.732 | 4.654 / 4.275 / 3.743 | 4.164 / 3.696 / 3.271 |
| Running Current amps (Cooling / Heating) | 8.6 / 8.1 | 9.9 / 9.5 | 11.7 / 10.6 |
| Moisture Removal l/hr | 4 | 5.3 | 4.6 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 44 / 35 | 46 / 39 | 50 / 42 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 44 / 35 | 46 / 39 | 50 / 42 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 57 / 58 | 59 / 61 | 60 / 62 |
| Outdoor Sound Power dBA | 75 | 76 | 76 |
| Static Pressure Range PA (Min to Max) | 60 to 200 | 60 to 200 | 60 to 200 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 1139 | 1194 | 1400 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 1139 | 1194 | 1400 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 360 x 1400 x 850 | 360 x 1400 x 850 | 360 x 1400 x 850 |
| Indoor Unit Weight kg | 69.00 | 69.00 | 79.00 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 1418 x 970 x 370 | 1418 x 970 x 370 | 1418 x 970 x 370 |
| Outdoor Unit Weight kg | 102.00 | 107.00 | 107.00 |
| Piping Connects mm Ø (Liquid / Gas) | 9.52 / 15.88 | 12.7 / 19.05 | 12.7 / 19.05 |
| Pipe Length m (Max (Precharged)) | 75 (30) | 75 (30) | 75 (30) |
| Max Height Difference m | 30 | 30 | 30 |
| Operation Range Cooling °CDB (Min to Max) | -15 to 50 | -15 to 50 | -15 to 50 |
| Operation Range Heating °CDB (Min to Max) | -20 to 24 | -20 to 24 | -20 to 24 |
| Refrigerant Type | R32 | R32 | R32 |
| Refrigerant Amount g | 3,800 | 4,500 | 4,500 |
| Return Air Connection (H x W) | 316 x 1295 | 316 x 1295 | 316 x 1295 |
| Supply Air Connection (H x W) | 277 x 1162 | 277 x 1162 | 277 x 1162 |
| UART Communication | Yes | Yes | Yes |
| UART Communication Port | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 |
Source: GENERAL Australia (Fujitsu), Large Capacity High Static Three Phase range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu Bulkhead
Small ducted units for one or two rooms, concealed in a bulkhead or ceiling with only the grilles visible. GENERAL Australia lists these under its single room solutions.
Bulkhead units are concealed in a bulkhead or ceiling space and deliver air to one or two rooms through short duct runs. See our bulkhead air conditioner installation page for how we plan and install them in Melbourne homes.
Key facts
- Refrigerant: R32
- Operation: Reverse Cycle
- Compatible controller options listed: UTY-RNRYZ3
| Model | Nominal size (kW) | Cooling (kW) | Heating (kW) |
|---|---|---|---|
| ARTH09KSLAP | 2.5 | 2.50 | 3.20 |
| ARTH12KSLAP | 3.5 | 3.50 | 4.00 |
| ARTH18KSLAP | 5.0 | 5.00 | 6.00 |
Nominal sizes as listed in the range summary on the official page. Cooling and heating figures are rated capacities as published by the manufacturer.
Features listed by the manufacturer
- All DC
- Auto Restart
- Auto Changeover
- Blue Fin Heat Exchanger
- Economy Mode
- Fresh Air Intake
- On-Off Timer
- Removable Intake Grill
- Weekly + Setback Timer
- Weekly Timer
- Automatic Air Flow Adjustment
- Connectable Distributing Duct
Official Bulkhead brochure (GENERAL Australia on Issuu) | Official range page
Specifications: Bulkhead (3 models)
| Model | ARTH09KSLAP | ARTH12KSLAP | ARTH18KSLAP |
|---|---|---|---|
| Power supply | Single phase (1P) | Single phase (1P) | Single phase (1P) |
| Operation Type | Reverse Cycle | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
| Capacity Class kW | 2.5 | 3.5 | 5 |
| Cooling Capacity kW (Rated (Min - Max)) | 2.50 (0.9 - 3.6) | 3.50 (0.9 - 4.1) | 5.00 (0.9 - 5.9) |
| Heating Capacity kW (Rated (Min - Max)) | 3.20 (0.9 - 4.5) | 4.00 (0.9 - 5.1) | 6.00 (0.9 - 7.1) |
| Input Power Cooling kW (Rated (Max)) | 0.64 (1.15) | 0.98 (1.41) | 1.48 (1.95) |
| Input Power Heating kW (Rated (Max)) | 0.8 (1.5) | 1.1 (1.97) | 1.73 (2.58) |
| EER Cooling kW/kW | 3.91 | 3.57 | 3.38 |
| COP Heating kW/kW | 4 | 3.64 | 3.47 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 3 / 2.5 / 3 | 3 / 2.5 / 2.5 | 3 / 2.5 / 2.5 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 2.5 / 2.5 / 2 | 2.5 / 2 / 1.5 | 2.5 / 2 / 1.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.999 / 4.49 / 4.551 | 4.645 / 4.269 / 4.374 | 4.584 / 4.264 / 4.418 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.339 / 4.053 / 3.736 | 4.371 / 3.934 / 3.492 | 4.43 / 3.86 / 3.319 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 5.371 / 5.359 / 5.663 | 4.97 / 5.006 / 5.313 | 4.912 / 5 / 5.339 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.329 / 4.151 / 3.879 | 4.373 / 4.109 / 3.73 | 4.439 / 4.094 / 3.628 |
| Running Current amps (Cooling / Heating) | 3.2 / 4.1 | 4.6 / 5.1 | 6.3 / 7.3 |
| Moisture Removal l/hr | 0.5 | 1.5 | 2 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 29 / 23 | 31 / 23 | 33 / 23 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 29 / 23 | 31 / 23 | 33 / 23 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 41 / 46 | 47 / 48 | 48 / 49 |
| Outdoor Sound Power dBA | 59 | 61 | 62 |
| Static Pressure Range PA (Min to Max) | 0 to 30 | 0 to 30 | 0 to 50 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 167 | 181 | 261 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 167 | 181 | 261 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 198 x 700 x 450 | 198 x 700 x 450 | 198 x 900 x 450 |
| Indoor Unit Weight kg | 15.50 | 15.50 | 18.50 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 542 x 799 x 290 | 542 x 799 x 290 | 632 x 799 x 290 |
| Outdoor Unit Weight kg | 32.00 | 32.00 | 36.00 |
| Piping Connects mm Ø (Liquid / Gas) | 6.35 / 9.52 | 6.35 / 9.52 | 6.35 / 12.7 |
| Pipe Length m (Max (Precharged)) | 20 (15) | 20 (15) | 30 (20) |
| Max Height Difference m | 15 | 15 | 20 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 46 | -10 to 46 | -10 to 46 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 | -15 to 24 | -15 to 24 |
| Refrigerant Type | R32 | R32 | R32 |
| Refrigerant Amount g | 850 | 850 | 1,020 |
Source: GENERAL Australia (Fujitsu), Bulkhead range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
How we install a Fujitsu ducted system in Melbourne
- Enquiry and assessment. We discuss the rooms you want to heat and cool, then assess the home, including room sizes, insulation, windows and orientation, and where the indoor and outdoor units can go.
- Recommendation and written quote. We recommend a Fujitsu ducted range and capacity that suits the home and explain the options before you commit.
- Installation. Our team installs the indoor and outdoor units, runs the refrigerant pipework and condensate drain, and completes the electrical connection as required by Victorian regulations.
- Commissioning and handover. We test heating and cooling operation, set up the controller and show you how to use the system and look after the filters.
- Ongoing service. Regular maintenance keeps the system running efficiently. See our maintenance services.
Manufacturer warranty
Fujitsu air conditioners in Australia are supplied by GENERAL Australia (formerly Fujitsu General Australia). The company changed its name on 1 January 2026 and continues to market products under the Fujitsu and General Airstage brands (source). Its official website is now generalairstage.com.au.
GENERAL Australia states that it "provides a 5 year full parts and labour warranty for all domestic air conditioning systems sold in Australia" (GENERAL Australia warranty information). Conditions are set out in the manufacturer's warranty card. We register the details of your installation and can assist if a warranty claim is needed.
Victorian Energy Upgrades
EZYAIR is a Victorian Energy Upgrades (VEU) accredited provider (A2261). If you are replacing an older heater with an efficient reverse cycle system, ask us whether your project may be eligible for a VEU discount. Eligibility depends on the existing heater, the new product and the program rules at the time. Learn more on our Victorian Energy Upgrades page.
You can see a range of wall hung, ducted and bulkhead units on display, many of them operational, at our Burwood showroom at 49 Huntingdale Rd, Burwood VIC 3125.
Related pages
- Fujitsu air conditioning in Melbourne (overview)
- Fujitsu split systems
- Fujitsu multi split systems
- Ducted reverse cycle air conditioning in Melbourne
- Ducted heating in Melbourne
- Bulkhead air conditioner installation
- Ducted air conditioning maintenance
- Other ducted brands we install: Daikin ducted air conditioning, Mitsubishi Electric ducted air conditioning, Panasonic ducted air conditioning and Midea ducted air conditioning
- Victorian Energy Upgrades (VEU) program
Fujitsu ducted air conditioning FAQs
Which Fujitsu ducted range suits a Melbourne home?
It depends on the size of the home, the roof or ceiling space available and whether you have single phase or three phase power. Slimline models suit tight ceiling spaces, while the high static ranges suit larger homes with more outlets. We assess the home before recommending a model.
Can a Fujitsu ducted system be zoned?
Yes. GENERAL Australia lists zone control or zone system compatibility for its current R32 ducted ranges, so you can heat or cool selected areas of the home rather than the whole house.
Do Fujitsu ducted systems heat as well as cool?
Yes. The ducted ranges listed on this page are reverse cycle, so they provide heating in winter and cooling in summer. Published heating capacities for each model are shown in the specification tables.
What warranty applies to Fujitsu ducted air conditioning?
GENERAL Australia states that it provides a 5 year full parts and labour warranty for all domestic air conditioning systems sold in Australia. Conditions are set out in the manufacturer's warranty card.
Can EZYAIR replace my old ducted heater with a Fujitsu ducted system?
Yes. We regularly replace older ducted heating with reverse cycle ducted systems. As a VEU accredited provider (A2261) we can also check whether your project may be eligible for a Victorian Energy Upgrades discount.
What capacities do Fujitsu ducted systems come in?
The Fujitsu ducted and bulkhead ranges on this page are rated from 2.5 kW (Bulkhead) to 22.4 kW cooling (Large Capacity High Static Three Phase), as published by GENERAL Australia. Each range section shows the rated cooling and heating capacity of every model. We calculate the heat load of your home before recommending a size.
Does Fujitsu make a bulkhead ducted unit?
Yes. The Fujitsu Bulkhead range is rated from 2.5 to 5.0 kW cooling, uses R32 refrigerant and has a published indoor unit height of 198 mm. It suits one or two rooms; see our bulkhead air conditioning installation page.
Request a quote
Planning Fujitsu ducted air conditioning for your Melbourne home? Contact EZYAIR or call 1300 EZYAIR (1300 399 247).