Fujitsu Split Systems Melbourne
A Fujitsu split system pairs one indoor unit with one outdoor unit to heat and cool a single room or open living area. EZYAIR supplies and installs Fujitsu split systems across Melbourne, including wall mounted, floor console and ceiling cassette models.

Who a Fujitsu split system suits
Split systems suit bedrooms, studies and living areas, and are a cost effective way to add efficient reverse cycle heating to a Melbourne home. If you want to condition several rooms with a single outdoor unit, consider a Fujitsu multi split system. For whole home comfort, see Fujitsu ducted air conditioning.
Current Fujitsu split system ranges
The following single room ranges are listed on the official GENERAL Australia website at the time of writing (October 2026). Fujitsu bulkhead units are covered on our Fujitsu ducted page.
- Fujitsu Lifestyle Range
- Fujitsu Lifestyle Next Range
- Fujitsu Comfort Range
- Fujitsu Comfort Cooling Range
- Fujitsu Compact Cassette
- Fujitsu Floor Console
- Fujitsu Floor/Ceiling Dual Console
EZYAIR is an independent air conditioning installer. Product information on this page is copied from the official GENERAL Australia (Fujitsu) website and brochures. Figures are as published by the manufacturer. Where a figure is not published it is not shown. Tables scroll sideways on smaller screens.
Fujitsu Lifestyle Range
Wall mounted split systems with a stylish design and efficiency features such as Human Sensor control and Economy mode. EZYAIR lists several Lifestyle models in our online store (see below).
- Models and rated capacities as published: ASTG09KMTC (2.50 kW cooling 3.20 kW heating); ASTG12KMTC (3.50 kW cooling 3.70 kW heating); ASTH18KMTD (5.00 kW cooling 6.00 kW heating); ASTG18KMTC (5.00 kW cooling 6.00 kW heating); ASTG22KMTC (6.00 kW cooling 7.20 kW heating); ASTH22KMTD (6.00 kW cooling 7.20 kW heating); ASTG24KMTC (7.10 kW cooling 8.00 kW heating); ASTH24KMTD (7.10 kW cooling 8.00 kW heating); ASTH24KMTE (7.10 kW cooling 8.00 kW heating); ASTG30KMTC (8.50 kW cooling 9.00 kW heating); ASTH30KMTD (8.50 kW cooling 9.00 kW heating); ASTG34KMTC (9.40 kW cooling 10.30 kW heating); ASTH34KMTD (9.50 kW cooling 10.30 kW heating)
- Refrigerant: R32
- Operation: Reverse Cycle
- Range summary on the official page: Split System, Reverse Cycle - 2.5kW, 3.5kW, 5.0kW, 6.0kW, 7.1kW, 8.5kW, 9.4kW, 9.5kW, R32
- Features listed by the manufacturer: 10°C Heat Operation, All DC, Apple-Catechin Filter, Auto Restart, Auto Shut Louvre, Auto Changeover, Automatic Air Flow Adjustment, Automatic Louvre, Blue Fin Heat Exchanger, Economy Mode, Filter Sign, Human Sensor, i-PAM, Long-Life Ion Deodorisation Filter, Low Noise Mode, On-Off Timer, Powerful Mode, Program Timer, Sleep Timer, Super Quiet Mode, Up/Down Swing Louvre, V-PAM, Washable Panel, Weekly + Setback Timer, Weekly Timer, Demand Response
- Compatible controller options listed: AR-REW3E, AR-REW1E
Official Lifestyle Range brochure (GENERAL Australia on Issuu) | Official range page
Lifestyle models in our store (contact us for a quote that includes installation): ASTG09KMTC 2.5 kW | ASTG12KMTC 3.5 kW | ASTH18KMTD 5.0 kW | ASTH22KMTD 6.0 kW | ASTH24KMTD 7.1 kW | ASTH30KMTD 8.5 kW | ASTH34KMTD 9.5 kW
Specifications: Lifestyle Range (13 models)
| Model | ASTG09KMTC | ASTG12KMTC | ASTH18KMTD | ASTG18KMTC | ASTG22KMTC | ASTH22KMTD | ASTG24KMTC | ASTH24KMTD | ASTH24KMTE | ASTG30KMTC | ASTH30KMTD | ASTG34KMTC | ASTH34KMTD |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Operation Type | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
| Cooling Capacity kW (Rated (Min - Max)) | 2.50 (0.8 - 3.6) | 3.50 (0.8 - 4.1) | 5.00 (1 - 6.5) | 5.00 (1 - 6.5) | 6.00 (1.1 - 7.5) | 6.00 (1.1 - 7.5) | 7.10 (1.1 - 8.3) | 7.10 (1.1 - 8.3) | 7.10 (1.1 - 8.3) | 8.50 (2.9 - 10.5) | 8.50 (2.9 - 10.5) | 9.40 (2.9 - 11.2) | 9.50 (2.9 - 11.2) |
| Heating Capacity kW (Rated (Min - Max)) | 3.20 (0.9 - 5.3) | 3.70 (0.9 - 6.1) | 6.00 (1.05 - 8.7) | 6.00 (1.05 - 8.7) | 7.20 (1.1 - 9.4) | 7.20 (1.1 - 9.4) | 8.00 (1.1 - 10.1) | 8.00 (1.1 - 10.1) | 8.00 (1.1 - 10.1) | 9.00 (2.2 - 11.2) | 9.00 (2.7 - 11.2) | 10.30 (2.7 - 11.7) | 10.30 (2.9 - 11.7) |
| Input Power Cooling kW (Rated (Min - Max)) | 0.53 (0.15 - 1.04) | 0.89 (0.15 - 1.29) | 1.16 (0.24 - 1.93) | 1.16 (0.24 - 1.68) | 1.58 (0.24 - 2.3) | 1.58 (0.24 - 2.72) | 2.08 (0.24 - 3.15) | 2.08 (0.24 - 3.15) | 2.2 (0.24 - 3.15) | 2.46 (0.58 - 3.85) | 2.49 (0.6 - 4) | 2.78 (0.59 - 4.03) | 2.72 (0.66 - 4.2) |
| Input Power Heating kW (Rated (Min - Max)) | 0.66 (0.25 - 1.61) | 0.79 (0.25 - 1.89) | 1.28 (0.14 - 2.75) | 1.28 (0.14 - 2.42) | 1.7 (0.14 - 2.63) | 1.7 (0.14 - 2.75) | 1.91 (0.14 - 3) | 1.91 (0.14 - 3.17) | 2.04 (0.14 - 3.17) | 2.34 (0.5 - 4.01) | 2.39 (0.48 - 3.6) | 2.84 (0.6 - 4.24) | 3.04 (0.68 - 3.8) |
| EER Cooling kW/kW | 4.71 | 3.93 | 4.31 | 4.31 | 3.8 | 3.8 | 3.41 | 3.41 | 3.23 | 3.45 | 3.41 | 3.38 | 3.49 |
| COP Heating kW/kW | 4.84 | 4.68 | 4.69 | 4.69 | 4.24 | 4.24 | 4.19 | 4.19 | 3.92 | 3.84 | 3.77 | 3.63 | 3.39 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 5.5 / 5 / 5.5 | 4.5 / 4.5 / 5 | 5 / 4.5 / 5 | 4.5 / 4.5 / 4.5 | 4 / 4 / 4 | 4.5 / 4 / 4.5 | 3.5 / 3.5 / 3.5 | 3.5 / 3.5 / 3.5 | 3.5 / 3.5 / 4 | 3 / 2.5 / 2.5 | 4 / 3.5 / 4 | 3 / 2.5 / 2.5 | 4 / 3.5 / 4 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3.5 / 3 / 3 | 3.5 / 3 / 2.5 | 3.5 / 3 / 2.5 | 3.0 / 2.5 / 2.5 | 3 / 2.5 / 2 | 3 / 2.5 / 2 | 3 / 2.5 / 2 | 3 / 2.5 / 2 | 3.5 / 2.5 / 2 | 2.5 / 2 / 2 | 4 / 3 / 2 | 2 / 2 / 1.5 | 3.5 / 2.5 / 1.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 7.219 / 6.755 / 7.155 | 6.477 / 6.193 / 6.625 | 6.652 / 6.3 / 6.726 | 6.46 / 6.102 / 6.472 | 5.852 / 5.558 / 5.943 | 6.009 / 5.714 / 6.146 | 5.307 / 5.039 / 5.4 | 5.344 / 5.094 / 5.481 | 5.429 / 5.251 / 5.682 | 4.658 / 4.334 / 4.477 | 5.56 / 5.284 / 5.716 | 4.628 / 4.317 / 4.482 | 5.501 / 5.242 / 5.633 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 5.36 / 4.975 / 4.548 | 5.241 / 4.817 / 4.278 | 5.004 / 4.676 / 4.181 | 4.704 / 4.48 / 4.092 | 4.609 / 4.194 / 3.605 | 4.64 / 4.258 / 3.722 | 4.779 / 4.212 / 3.525 | 4.819 / 4.265 / 3.586 | 5.249 / 4.345 / 3.603 | 4.111 / 3.856 / 3.546 | 5.55 / 4.534 / 3.841 | 3.834 / 3.603 / 3.312 | 5.079 / 4.1 / 3.474 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 8.198 / 8.777 / 10.227 | 7.443 / 8.666 / 10.522 | 7.428 / 7.934 / 9.086 | 7.156 / 7.555 / 8.512 | 6.45 / 6.834 / 7.655 | 6.672 / 7.138 / 8.111 | 5.873 / 6.234 / 7.03 | 5.873 / 6.231 / 6.897 | 6.041 / 6.916 / 7.917 | 5.097 / 5.258 / 5.782 | 6.233 / 6.729 / 7.766 | 5.018 / 5.153 / 5.599 | 6.118 / 6.566 / 7.494 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 5.351 / 5.112 / 4.744 | 5.234 / 4.971 / 4.518 | 4.631 / 4.393 / 4.376 | 4.684 / 4.533 / 4.216 | 4.6 / 4.34 / 3.859 | 4.631 / 4.393 / 3.951 | 4.775 / 4.421 / 3.856 | 4.817 / 4.474 / 3.909 | 4.869 / 5.403 / 4.117 | 4.1 / 3.939 / 3.678 | 5.611 / 5.02 / 4.353 | 3.823 / 3.676 / 3.433 | 5.161 / 4.58 / 3.964 |
| Running Current amps (Cooling / Heating) | 3 / 3.5 | 4.2 / 4 | 5.3 / 5.8 | 5.1 / 5.6 | 6.8 / 7.4 | 7.1 / 7.7 | 8.9 / 8.3 | 9.3 / 8.7 | 9.8 / 9.3 | 10.4 / 10.1 | 11 / 10.6 | 11.7 / 11.9 | 12 / 13.4 |
| Moisture Removal l/hr | 0.3 | 1 | 1.3 | 1.3 | 2.3 | 2.3 | 2.7 | 2.7 | 2.7 | 2.5 | 4.4 | 3.5 | 4.9 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 40 / 19 | 40 / 19 | 46 / 29 | 46 / 29 | 48 / 29 | 48 / 29 | 49 / 29 | 49 / 29 | 49 / 29 | 51 / 33 | 51 / 32 | 52 / 34 | 51 / 34 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 40 / 21 | 42 / 21 | 46 / 29 | 46 / 29 | 48 / 29 | 48 / 29 | 49 / 29 | 49 / 29 | 49 / 29 | 51 / 33 | 48 / 32 | 51 / 33 | 51 / 33 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 46 / 46 | 49 / 49 | 47 / 49 | 47 / 48 | 49 / 52 | 49 / 52 | 54 / 52 | 54 / 53 | 54 / 53 | 50 / 54 | 53 / 55 | 50 / 54 | 58 / 59 |
| Outdoor Sound Power dBA | 55 | 59 | 59 | 59 | 61 | 61 | 66 | 66 | 66 | 66 | 65 | 65 | 70 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 194 | 194 | 283 | 283 | 294 | 294 | 325 | 325 | 325 | 389 | 381 | 389 | 381 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 197 | 214 | 286 | 283 | 294 | 300 | 325 | 331 | 331 | 389 | 350 | 389 | 372 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 270 x 834 x 222 | 270 x 834 x 222 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 340 x 1150 x 280 | 340 x 1150 x 280 | 340 x 1150 x 280 | 340 x 1150 x 280 |
| Indoor Unit Weight kg | 10.00 | 10.00 | 12.50 | 12.50 | 12.50 | 12.50 | 12.50 | 12.50 | 12.50 | 18.50 | 16.50 | 18.00 | 16.50 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 542 x 799 x 290 | 542 x 799 x 290 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 830 x 900 x 330 | 788 x 940 x 320 | 914 x 970 x 370 | 998 x 940 x 320 |
| Outdoor Unit Weight kg | 32.00 | 32.00 | 42.00 | 42.00 | 42.00 | 42.00 | 42.00 | 42.00 | 41.00 | 60.00 | 53.00 | 74.00 | 62.00 |
| Piping Connects mm Ø (Liquid / Gas) | 6.35 / 9.52 | 6.35 / 9.52 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 | 9.52 / 15.88 |
| Pipe Length m (Max (Precharged)) | 20 (15) | 20 (15) | 30 (15) | 30 (15) | 30 (15) | 30 (15) | 30 (15) | 30 (15) | 30 (15) | 75 (20) | 50 (20) | 75 (30) | 50 (25) |
| Max Height Difference m | 15 | 15 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 30 | 30 | 30 | 30 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 46 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 50 | -10 to 46 | -10 to 50 | -10 to 46 | -10 to 50 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 |
| Refrigerant Type | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 |
| Refrigerant Amount g | 850 | 850 | 1,270 | 1,320 | 1,320 | 1,270 | 1,320 | 1,270 | 1,270 | 1,650 | 1,700 | 2,000 | 2,300 |
| UART Communication | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| UART Communication Port | CN6 | CN6 | 2 Ports - CN65, CN75 | CN6 | CN6 | 2 Ports - CN65, CN75 | CN6 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | CN6 | 2 Ports - CN65, CN75 | CN6 | 2 Ports - CN65, CN75 |
Source: GENERAL Australia (Fujitsu), Lifestyle Range range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu Lifestyle Next Range
The manufacturer states that every Lifestyle Next purchase includes the anywAiR Wi-Fi adaptor II, giving smartphone control through the myanywAiR Next app with features such as geofencing, climate react and maintenance support.
- Models and rated capacities as published: SET-ASTG09KMTC-NXT (2.50 kW cooling 3.20 kW heating); SET-ASTG12KMTC-NXT (3.50 kW cooling 3.70 kW heating); SET-ASTH18KMTD-NXT (5.00 kW cooling 6.00 kW heating); SET-ASTH22KMTD-NXT (6.00 kW cooling 7.20 kW heating); SET-ASTH24KMTD-NXT (7.10 kW cooling 8.00 kW heating); SET-ASTH24KMTE-NXT (7.10 kW cooling 8.00 kW heating); SET-ASTH30KMTD-NXT (8.50 kW cooling 9.00 kW heating); SET-ASTH34KMTD-NXT (9.50 kW cooling 10.30 kW heating)
- Refrigerant: R32
- Operation: Reverse Cycle
- Range summary on the official page: Split System, Reverse Cycle - 2.5kW, 3.5kW, 5.0kW, 6.0kW, 7.1kW, 8.5kW, 9.5kW, R32
- Features listed by the manufacturer: 10°C Heat Operation, All DC, Apple-Catechin Filter, Auto Restart, Auto Shut Louvre, Auto Changeover, Automatic Air Flow Adjustment, Automatic Louvre, Blue Fin Heat Exchanger, Economy Mode, Filter Sign, Human Sensor, i-PAM, Long-Life Ion Deodorisation Filter, Low Noise Mode, On-Off Timer, Powerful Mode, Super Quiet Mode, Program Timer, Demand Response
- Compatible controller options listed: AR-REW3E, AR-REW1E, UTY-NXT
Official Lifestyle Next Range brochure (GENERAL Australia on Issuu) | Official range page
Specifications: Lifestyle Next Range (8 models)
| Model | SET-ASTG09KMTC-NXT | SET-ASTG12KMTC-NXT | SET-ASTH18KMTD-NXT | SET-ASTH22KMTD-NXT | SET-ASTH24KMTD-NXT | SET-ASTH24KMTE-NXT | SET-ASTH30KMTD-NXT | SET-ASTH34KMTD-NXT |
|---|---|---|---|---|---|---|---|---|
| Operation Type | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
| Cooling Capacity kW (Rated (Min - Max)) | 2.50 (0.8 - 3.6) | 3.50 (0.8 - 4.1) | 5.00 (1 - 6.5) | 6.00 (1.1 - 7.5) | 7.10 (1.1 - 8.3) | 7.10 (1.1 - 8.3) | 8.50 (2.9 - 10.5) | 9.50 (2.9 - 11.2) |
| Heating Capacity kW (Rated (Min - Max)) | 3.20 (0.9 - 5.3) | 3.70 (0.9 - 6.1) | 6.00 (1.05 - 8.7) | 7.20 (1.1 - 9.4) | 8.00 (1.1 - 10.1) | 8.00 (1.1 - 10.1) | 9.00 (2.7 - 11.2) | 10.30 (2.9 - 11.7) |
| Input Power Cooling kW (Rated (Min - Max)) | 0.53 (0.15 - 1.04) | 0.89 (0.15 - 1.29) | 1.16 (0.24 - 1.93) | 1.58 (0.24 - 2.72) | 2.08 (0.24 - 3.15) | 2.2 (0.24 - 3.15) | 2.49 (0.6 - 4) | 2.72 (0.66 - 4.2) |
| Input Power Heating kW (Rated (Min - Max)) | 0.66 (0.25 - 1.61) | 0.79 (0.25 - 1.89) | 1.28 (0.14 - 2.75) | 1.7 (0.14 - 2.75) | 1.91 (0.14 - 3.17) | 2.04 (0.14 - 3.17) | 2.39 (0.48 - 3.6) | 3.04 (0.68 - 3.8) |
| EER Cooling kW/kW | 4.71 | 3.93 | 4.31 | 3.8 | 3.41 | 3.23 | 3.41 | 3.49 |
| COP Heating kW/kW | 4.84 | 4.68 | 4.69 | 4.24 | 4.19 | 3.92 | 3.77 | 3.39 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 5.5 / 5 / 5.5 | 4.5 / 4.5 / 5 | 5 / 4.5 / 5 | 4.5 / 4 / 4.5 | 3.5 / 3.5 / 3.5 | 3.5 / 3.5 / 4 | 4 / 3.5 / 4 | 4 / 3.5 / 4 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3.5 / 3 / 3 | 3.5 / 3 / 2.5 | 3.5 / 3 / 2.5 | 3 / 2.5 / 2 | 3 / 2.5 / 2 | 3.5 / 2.5 / 2 | 4 / 3 / 2 | 3.5 / 2.5 / 1.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 7.219 / 6.755 / 7.155 | 6.477 / 6.193 / 6.625 | 6.652 / 6.3 / 6.726 | 6.009 / 5.714 / 6.146 | 5.344 / 5.094 / 5.481 | 5.429 / 5.251 / 5.682 | 5.56 / 5.284 / 5.716 | 5.501 / 5.242 / 5.633 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 5.36 / 4.975 / 4.548 | 5.241 / 4.817 / 4.278 | 5.004 / 4.676 / 4.181 | 4.64 / 4.258 / 3.722 | 4.819 / 4.265 / 3.586 | 5.249 / 4.345 / 3.603 | 5.55 / 4.534 / 3.841 | 5.079 / 4.1 / 3.474 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 8.198 / 8.777 / 10.227 | 7.443 / 8.666 / 10.522 | 7.428 / 7.934 / 9.086 | 6.672 / 7.138 / 8.111 | 5.873 / 6.231 / 6.897 | 6.041 / 6.916 / 7.917 | 6.233 / 6.729 / 7.766 | 6.118 / 6.566 / 7.494 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 5.351 / 5.112 / 4.744 | 5.234 / 4.971 / 4.518 | 4.631 / 4.393 / 4.376 | 4.631 / 4.393 / 3.951 | 4.817 / 4.474 / 3.909 | 4.869 / 5.403 / 4.117 | 5.611 / 5.02 / 4.353 | 5.161 / 4.58 / 3.964 |
| Running Current amps (Cooling / Heating) | 3 / 3.5 | 4.2 / 4 | 5.3 / 5.8 | 7.1 / 7.7 | 9.3 / 8.7 | 9.8 / 9.3 | 11 / 10.6 | 12 / 13.4 |
| Moisture Removal l/hr | 0.3 | 1 | 1.3 | 2.3 | 2.7 | 2.7 | 4.4 | 4.9 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 40 / 19 | 40 / 19 | 46 / 29 | 48 / 29 | 49 / 29 | 49 / 29 | 51 / 32 | 51 / 34 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 40 / 21 | 42 / 21 | 46 / 29 | 48 / 29 | 49 / 29 | 49 / 29 | 48 / 32 | 51 / 33 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 46 / 46 | 49 / 49 | 47 / 49 | 49 / 52 | 54 / 53 | 54 / 53 | 53 / 55 | 58 / 59 |
| Outdoor Sound Power dBA | 55 | 59 | 59 | 61 | 66 | 66 | 65 | 70 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 194 | 194 | 283 | 294 | 325 | 325 | 381 | 381 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 197 | 214 | 286 | 300 | 331 | 331 | 350 | 372 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 270 x 834 x 222 | 270 x 834 x 222 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 280 x 980 x 240 | 340 x 1150 x 280 | 340 x 1150 x 280 |
| Indoor Unit Weight kg | 10.00 | 10.00 | 12.50 | 12.50 | 12.50 | 12.50 | 16.50 | 16.50 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 542 x 799 x 290 | 542 x 799 x 290 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 716 x 820 x 315 | 788 x 940 x 320 | 998 x 940 x 320 |
| Outdoor Unit Weight kg | 32.00 | 32.00 | 42.00 | 42.00 | 42.00 | 41.00 | 53.00 | 62.00 |
| Piping Connects mm Ø (Liquid / Gas) | 6.35 / 9.52 | 6.35 / 9.52 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 9.52 / 15.88 | 9.52 / 15.88 |
| Pipe Length m (Max (Precharged)) | 20 (15) | 20 (15) | 30 (15) | 30 (15) | 30 (15) | 30 (15) | 50 (20) | 50 (25) |
| Max Height Difference m | 15 | 15 | 25 | 25 | 25 | 25 | 30 | 30 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 46 | -10 to 46 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 |
| Refrigerant Type | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 |
| Refrigerant Amount g | 850 | 850 | 1,270 | 1,270 | 1,270 | 1,270 | 1,700 | 2,300 |
| UART Communication | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| UART Communication Port | CN6 | CN6 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 |
Source: GENERAL Australia (Fujitsu), Lifestyle Next Range range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu Comfort Range
A reverse cycle wall mounted range for all year round heating and cooling, described by the manufacturer as having options to suit almost any room.
- Models and rated capacities as published: ASTH09KNCA (2.50 kW cooling 3.20 kW heating); ASTH12KNCA (3.40 kW cooling 4.00 kW heating); ASTH14KNCA (4.20 kW cooling 4.70 kW heating); ASTH18KNTA (5.00 kW cooling 5.20 kW heating); ASTH22KNTA (6.00 kW cooling 6.50 kW heating); ASTH24KNTA (7.10 kW cooling 8.00 kW heating); ASTH30KNTA (8.50 kW cooling 9.00 kW heating); ASTH34KNTA (9.50 kW cooling 10.30 kW heating)
- Refrigerant: R32
- Operation: Reverse Cycle
- Features listed by the manufacturer: All DC, Auto Restart, Auto Shut Louvre, Auto Changeover, Automatic Louvre, Blue Fin Heat Exchanger, Economy Mode, Filter Sign, i-PAM, On-Off Timer, Program Timer, Sleep Timer, Super Quiet Mode, Up/Down Swing Louvre, V-PAM, Washable Panel, 0.5°C Increments, Powerful Mode
- Compatible controller options listed: AR-RPD2E
Official Comfort Range brochure (GENERAL Australia on Issuu) | Official range page
Specifications: Comfort Range (8 models)
| Model | ASTH09KNCA | ASTH12KNCA | ASTH14KNCA | ASTH18KNTA | ASTH22KNTA | ASTH24KNTA | ASTH30KNTA | ASTH34KNTA |
|---|---|---|---|---|---|---|---|---|
| Operation Type | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
| Cooling Capacity kW (Rated (Min - Max)) | 2.50 (0.9 - 3.7) | 3.40 (0.9 - 3.7) | 4.20 (0.9 - 4.4) | 5.00 (0.9 - 5.6) | 6.00 (0.9 - 6.5) | 7.10 (1 - 8) | 8.50 (2.9 - 10.5) | 9.50 (2.9 - 11.2) |
| Heating Capacity kW (Rated (Min - Max)) | 3.20 (0.9 - 4.8) | 4.00 (0.9 - 4.9) | 4.70 (0.9 - 5.8) | 5.20 (0.9 - 7) | 6.50 (0.9 - 7.7) | 8.00 (1 - 9.6) | 9.00 (2.7 - 11.2) | 10.30 (2.9 - 11.7) |
| Input Power Cooling kW (Rated (Min - Max)) | 0.59 (0.25 - 1.14) | 0.96 (0.25 - 1.27) | 1.23 (0.25 - 1.4) | 1.44 (0.14 - 1.74) | 1.78 (0.12 - 2.07) | 2.2 (0.16 - 3) | 2.49 (0.6 - 4) | 2.72 (0.66 - 4.2) |
| Input Power Heating kW (Rated (Min - Max)) | 0.77 (0.25 - 1.6) | 1 (0.25 - 1.52) | 1.13 (0.25 - 1.73) | 1.33 (0.12 - 2.17) | 1.85 (0.12 - 2.4) | 2.08 (0.16 - 2.74) | 2.39 (0.48 - 3.6) | 3.04 (0.68 - 3.8) |
| EER Cooling kW/kW | 4.24 | 3.54 | 3.41 | 3.47 | 3.37 | 3.23 | 3.41 | 3.49 |
| COP Heating kW/kW | 4.16 | 4 | 4.16 | 3.91 | 3.51 | 3.85 | 3.77 | 3.39 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 5 / 4.5 / 4.5 | 4 / 3.5 / 4 | 4 / 3.5 / 4 | 3.5 / 3.5 / 3.5 | 3.5 / 3.5 / 3.5 | 3.5 / 3 / 3.5 | 4 / 3.5 / 4 | 4 / 3.5 / 4 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3.5 / 3 / 2.5 | 3 / 2.5 / 2 | 3.5 / 3 / 2 | 3 / 2.5 / 2 | 3 / 2 / 1.5 | 3.5 / 2.5 / 2 | 4 / 3 / 2 | 3.5 / 2.5 / 1.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 6.535 / 6.114 / 6.476 | 5.536 / 5.235 / 5.599 | 5.55 / 5.262 / 5.691 | 5.395 / 5.122 / 5.491 | 5.963 / 6.36 / 7.187 | 5.639 / 5.982 / 6.66 | 5.56 / 5.284 / 5.716 | 5.501 / 5.242 / 5.633 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 5.235 / 4.625 / 4.005 | 4.955 / 4.207 / 3.507 | 5.25 / 4.54 / 3.801 | 4.961 / 4.28 / 3.575 | 4.901 / 3.982 / 3.268 | 5.329 / 4.407 / 3.573 | 5.55 / 4.534 / 3.841 | 5.079 / 4.1 / 3.474 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 7.49 / 8.084 / 9.563 | 6.182 / 6.603 / 7.532 | 6.165 / 6.593 / 7.47 | 5.911 / 6.244 / 6.933 | 5.377 / 5.101 / 5.495 | 5.143 / 4.897 / 5.288 | 6.233 / 6.729 / 7.766 | 6.566 / 6.566 / 7.494 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 5.244 / 4.875 / 4.339 | 4.962 / 4.521 / 3.948 | 5.26 / 4.825 / 4.191 | 4.97 / 4.554 / 3.948 | 4.922 / 4.379 / 3.599 | 5.35 / 4.779 / 4.047 | 5.611 / 5.02 / 4.353 | 5.079 / 4.58 / 3.964 |
| Running Current amps (Cooling / Heating) | 3 / 3.8 | 4.8 / 5.1 | 5.9 / 5.6 | 6.4 / 5.8 | 7.9 / 8.2 | 9.6 / 9.2 | 11 / 10.6 | 12 / 13.4 |
| Moisture Removal l/hr | 1 | 1.2 | 1.6 | 2.3 | 2.9 | 3.2 | 4.4 | 4.9 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 46 / 22 | 40 / 20 | 43 / 20 | 46 / 27 | 48 / 31 | 50 / 31 | 51 / 32 | 51 / 34 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 46 / 27 | 42 / 22 | 44 / 24 | 46 / 29 | 48 / 31 | 48 / 31 | 48 / 32 | 51 / 33 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 49 / 51 | 50 / 50 | 50 / 50 | 49 / 49 | 54 / 53 | 55 / 56 | 53 / 55 | 58 / 59 |
| Outdoor Sound Power dBA | 62 | 65 | 65 | 61 | 68 | 67 | 65 | 70 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 175 | 194 | 214 | 225 | 244 | 336 | 381 | 381 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 175 | 217 | 228 | 225 | 244 | 311 | 350 | 372 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 270 x 784 x 224 | 270 x 834 x 215 | 270 x 834 x 215 | 270 x 834 x 232 | 270 x 834 x 232 | 280 x 980 x 240 | 340 x 1150 x 280 | 340 x 1150 x 280 |
| Indoor Unit Weight kg | 8.00 | 9.50 | 10.00 | 11.00 | 11.00 | 12.50 | 16.50 | 16.50 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 541 x 663 x 290 | 541 x 663 x 290 | 541 x 799 x 290 | 542 x 799 x 290 | 632 x 799 x 290 | 632 x 799 x 290 | 788 x 940 x 320 | 998 x 940 x 320 |
| Outdoor Unit Weight kg | 25.00 | 25.00 | 31.00 | 33.00 | 36.00 | 39.00 | 53.00 | 62.00 |
| Piping Connects mm Ø (Liquid / Gas) | 6.35 / 9.52 | 6.35 / 9.52 | 6.35 / 9.52 | 6.35 / 12.7 | 6.35 / 12.7 | 6.35 / 12.7 | 9.52 / 15.88 | 9.52 / 15.88 |
| Pipe Length m (Max (Precharged)) | 20 (15) | 20 (15) | 20 (15) | 25 (15) | 25 (15) | 30 (15) | 30 (20) | 30 (25) |
| Max Height Difference m | 15 | 15 | 15 | 20 | 20 | 25 | 20 | 20 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 | -10 to 50 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 |
| Refrigerant Type | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 |
| Refrigerant Amount g | 590 | 700 | 850 | 890 | 960 | 1,200 | 1,700 | 2,300 |
| UART Communication | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| UART Communication Port | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 |
Source: GENERAL Australia (Fujitsu), Comfort Range range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu Comfort Cooling Range
Cooling only wall mounted models, suited to rooms where heating is provided by another system.
- Models and rated capacities as published: ASTH09CNCA (2.50 kW cooling); ASTH12CNCA (3.40 kW cooling); ASTH18CNTA (5.00 kW cooling); ASTH24CNTA (7.10 kW cooling); ASTH30CNTA (8.50 kW cooling); ASTH34CNTA (9.50 kW cooling)
- Refrigerant: R32
- Operation: Cooling Only
- Features listed by the manufacturer: Apple-Catechin Filter, All DC, Auto Restart, Auto Shut Louvre, Automatic Louvre, Blue Fin Heat Exchanger, DRED Standard Equipment, Economy Mode, Filter Sign, i-PAM, Long-Life Ion Deodorisation Filter, Precise Temperature Control, Program Timer, Powerful Mode, On-Off Timer, Super Quiet Mode, Sleep Timer, Up/Down Swing Louvre, Washable Panel, V-PAM
- Compatible controller options listed: AR-RPD5E
Official Comfort Cooling Range brochure (GENERAL Australia on Issuu) | Official range page
Specifications: Comfort Cooling Range (6 models)
| Model | ASTH09CNCA | ASTH12CNCA | ASTH18CNTA | ASTH24CNTA | ASTH30CNTA | ASTH34CNTA |
|---|---|---|---|---|---|---|
| Operation Type | Cooling Only | Cooling Only | Cooling Only | Cooling Only | Cooling Only | Cooling Only |
| Power Source V/Ph/Hz | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
| Cooling Capacity kW (Rated (Min - Max)) | 2.50 (0.9 - 3.7) | 3.40 (0.9 - 3.7) | 5.00 (0.9 - 5.6) | 7.10 (1 - 8) | 8.50 (2.9 - 10.5) | 9.50 (2.9 - 11.2) |
| Input Power Cooling kW (Rated (Max)) | 0.59 (1.14) | 0.96 (1.27) | 1.44 (1.74) | 2.2 (3) | 2.3 (3.45) | 2.83 (3.85) |
| EER Cooling kW/kW | 4.24 | 3.54 | 3.47 | 3.23 | 3.7 | 3.36 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 5 / 4.5 / 4.5 | 4 / 3.5 / 4 | 3.5 / 3.5 / 3.5 | 3.5 / 3 / 3.5 | 4 / 4 / 4 | 3.5 / 3.5 / 3.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 6.538 / 6.121 / 6.486 | 5.537 / 5.239 / 5.605 | 5.395 / 5.122 / 5.491 | 5.143 / 4.897 / 5.288 | 5.773 / 5.501 / 5.895 | 5.235 / 5.005 / 5.383 |
| Running Current amps (Cooling) | 3 | 4.8 | 6.4 | 9.6 | 10.2 | 12.4 |
| Moisture Removal l/hr | 1 | 1.2 | 2.3 | 3.2 | 4.4 | 4.9 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 46 / 22 | 40 / 20 | 46 / 27 | 50 / 31 | 51 / 32 | 51 / 32 |
| Outdoor Sound Pressure dBA (Cooling) | 49 | 50 | 49 | 55 | 53 | 53 |
| Outdoor Sound Power dBA | 62 | 65 | 61 | 67 | 67 | 67 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 175 | 194 | 225 | 336 | 381 | 381 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 270 x 784 x 224 | 270 x 834 x 215 | 270 x 834 x 232 | 280 x 980 x 240 | 340 x 1150 x 280 | 340 x 1150 x 280 |
| Indoor Unit Weight kg | 8.00 | 9.50 | 11.00 | 12.50 | 16.50 | 16.50 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 541 x 663 x 290 | 541 x 663 x 290 | 542 x 799 x 290 | 632 x 799 x 290 | 788 x 940 x 320 | 788 x 940 x 320 |
| Outdoor Unit Weight kg | 25.00 | 25.00 | 37.00 | 42.00 | 52.00 | 52.00 |
| Piping Connects mm Ø (Liquid / Gas) | 6.35 / 9.52 | 6.35 / 9.52 | 6.35 / 12.7 | 6.35 / 12.7 | 9.52 / 15.88 | 9.52 / 15.88 |
| Pipe Length m (Max (Precharged)) | 20 (15) | 20 (15) | 25 (15) | 30 (15) | 50 (20) | 50 (20) |
| Max Height Difference m | 15 | 15 | 20 | 25 | 30 | 30 |
| Operation Range Cooling °CDB (Min to Max) | 10 to 50 | 10 to 50 | 10 to 50 | 10 to 50 | 10 to 50 | 10 to 50 |
| Refrigerant Type | R32 | R32 | R32 | R32 | R32 | R32 |
| Refrigerant Amount g | - | - | - | - | - | - |
| UART Communication | Yes | Yes | Yes | Yes | Yes | Yes |
| UART Communication Port | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 |
Source: GENERAL Australia (Fujitsu), Comfort Cooling Range range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu Compact Cassette
A ceiling cassette whose grille sits level with the ceiling, distributing air in up to four directions. A good option where wall space is limited.
- Models and rated capacities as published: AUTH09KVLA (2.50 kW cooling 3.20 kW heating); AUTH12KVLA (3.50 kW cooling 4.00 kW heating); AUTH18KVLA (5.00 kW cooling 6.00 kW heating); AUTH24KVLA (7.10 kW cooling 8.00 kW heating)
- Refrigerant: R32
- Operation: Reverse Cycle
- Features listed by the manufacturer: 10°C Heat Operation, All DC, Auto Restart, Auto Changeover, Automatic Louvre, Blue Fin Heat Exchanger, Economy Mode, i-PAM, Mildew Resistant Filter, On-Off Timer, Program Timer, Removable Intake Grill, Sleep Timer, Super Quiet Mode, V-PAM, Washable Panel, Automatic Air Flow Adjustment, Low Noise Mode
- Compatible controller options listed: AR-RAH1E, UTY-RNNYN, UTY-RVNYN, UTY-RNRYZ3, UTY-RSRY, UTY-RHRY, UTY-LNHY
Official Compact Cassette brochure (GENERAL Australia on Issuu) | Official range page
Specifications: Compact Cassette (4 models)
| Model | AUTH09KVLA | AUTH12KVLA | AUTH18KVLA | AUTH24KVLA |
|---|---|---|---|---|
| Operation Type | Reverse Cycle | Reverse Cycle | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
| Capacity Class kW | 2.5 | 3.5 | 5 | - |
| Cooling Capacity kW (Rated (Min - Max)) | 2.50 (0.9 - 3.6) | 3.50 (0.9 - 4.1) | 5.00 (0.9 - 5.9) | 7.10 (1.5 - 7.8) |
| Heating Capacity kW (Rated (Min - Max)) | 3.20 (0.9 - 4.5) | 4.00 (0.9 - 5.1) | 6.00 (0.9 - 7.1) | 8.00 (1.4 - 8.4) |
| Input Power Cooling kW (Rated (Max)) | 0.56 (1.13) | 0.9 (1.33) | 1.45 (2.39) | 2.16 (2.72) |
| Input Power Heating kW (Rated (Max)) | 0.76 (1.68) | 1.04 (1.88) | 1.71 (2.78) | 2.21 (2.71) |
| EER Cooling kW/kW | 4.46 | 3.89 | 3.45 | 3.29 |
| COP Heating kW/kW | 4.21 | 3.85 | 3.51 | 3.62 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 4 / 3.5 / 3.5 | 3.5 / 3 / 3 | 3 / 2.5 / 2.5 | 2.5 / 2.5 / 2.5 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3.5 / 3 / 2.5 | 3 / 2.5 / 2 | 3 / 2 / 1.5 | 3 / 2.5 / 2 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 5.804 / 5.126 / 5.179 | 5.206 / 4.74 / 4.862 | 4.666 / 4.325 / 4.474 | 4.401 / 4.187 / 4.365 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 5.064 / 4.575 / 4.108 | 4.822 / 4.268 / 3.714 | 4.574 / 3.954 / 3.376 | 4.58 / 4.044 / 3.533 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 6.273 / 6.243 / 6.595 | 5.599 / 5.651 / 6.011 | 5.002 / 5.085 / 5.426 | 4.685 / 4.789 / 5.119 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 5.067 / 4.771 / 4.364 | 4.83 / 4.495 / 4.017 | 4.586 / 4.21 / 3.709 | 4.588 / 4.265 / 3.822 |
| Running Current amps (Cooling / Heating) | 3 / 4 | 4.2 / 5 | 6.2 / 7.3 | 9.6 / 9.7 |
| Moisture Removal l/hr | 0.7 | 1.2 | 2 | 3.4 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 33 / 28 | 37 / 28 | 38 / 26 | 49 / 30 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 34 / 27 | 37 / 28 | 43 / 30 | 50 / 33 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 41 / 46 | 47 / 48 | 48 / 49 | 54 / 50 |
| Outdoor Sound Power dBA | 59 | 61 | 62 | 69 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 150 | 169 | 189 | 258 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 150 | 169 | 189 | 286 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 245 x 570 x 570 | 245 x 570 x 570 | 245 x 570 x 570 | 245 x 570 x 570 |
| Indoor Unit Weight kg | 15.00 | 15.00 | 15.00 | 16.00 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 542 x 799 x 290 | 542 x 799 x 290 | 632 x 799 x 290 | 788 x 940 x 320 |
| Outdoor Unit Weight kg | 32.00 | 32.00 | 36.00 | 53.00 |
| Grill Dimensions mm (Height x Width x Depth) | 49 x 620 x 620 | 49 x 620 x 620 | 49 x 620 x 620 | 49 x 620 x 620 |
| Grill Weight kg | 2.30 | 2.30 | 2.30 | 2.30 |
| Piping Connects mm Ø (Liquid / Gas) | 6.35 / 9.52 | 6.35 / 9.52 | 6.35 / 12.7 | 6.35 / 12.7 |
| Pipe Length m (Max (Precharged)) | 20 (15) | 20 (15) | 30 (20) | 30 (30) |
| Max Height Difference m | 15 | 15 | 20 | 30 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 46 | -10 to 46 | -10 to 46 | -10 to 50 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 | -15 to 24 | -15 to 24 | -15 to 24 |
| Refrigerant Type | R32 | R32 | R32 | R32 |
| Refrigerant Amount g | 850 | 850 | 1,020 | 1,500 |
| UART Communication | Yes | Yes | Yes | Yes |
| UART Communication Port | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 | 2 Ports - CN65, CN75 |
Source: GENERAL Australia (Fujitsu), Compact Cassette range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu Floor Console
Floor mounted units for rooms where wall space is limited, providing heating and cooling close to floor level.
- Models and rated capacities as published: AGTG09KVCA (2.50 kW cooling 3.50 kW heating); AGTG12KVCA (3.50 kW cooling 4.50 kW heating); AGTG14KVCA (4.20 kW cooling 5.20 kW heating)
- Refrigerant: R32
- Operation: Reverse Cycle
- Features listed by the manufacturer: 10°C Heat Operation, All DC, Apple-Catechin Filter, Auto Restart, Auto Shut Louvre, Auto Changeover, Automatic Air Flow Adjustment, Automatic Louvre, Blue Fin Heat Exchanger, Economy Mode, On-Off Timer, Program Timer, Sleep Timer, Up/Down Swing Louvre, V-PAM, Washable Panel, Coil Dry
- Compatible controller options listed: AR-RAC1E, UTY-RNNYN, UTY-RVNYN, UTY-RHRY, UTY-RSRY, UTY-RNRYZ3
Official Floor Console brochure (GENERAL Australia on Issuu) | Official range page
Specifications: Floor Console (3 models)
| Model | AGTG09KVCA | AGTG12KVCA | AGTG14KVCA |
|---|---|---|---|
| Operation Type | Reverse Cycle | Reverse Cycle | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 | 230 / 1 / 50 | 230 / 1 / 50 |
| Capacity Class kW | 2.5 | 3.5 | 4 |
| Cooling Capacity kW (Rated (Min - Max)) | 2.50 (0.9 - 3.5) | 3.50 (0.9 - 4.3) | 4.20 (0.9 - 5.2) |
| Heating Capacity kW (Rated (Min - Max)) | 3.50 (0.9 - 5.3) | 4.50 (0.9 - 6.1) | 5.20 (0.9 - 6.5) |
| Input Power Cooling kW (Rated (Max)) | 0.53 (1.32) | 0.85 (2.12) | 1.1 (2.12) |
| Input Power Heating kW (Rated (Max)) | 0.85 (1.66) | 1.11 (2.15) | 1.41 (2.15) |
| EER Cooling kW/kW | 4.7 | 4.1 | 3.8 |
| COP Heating kW/kW | 4.27 | 4.05 | 3.7 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 5.5 / 5 / 5 | 4.5 / 4 / 4.5 | 4 / 4 / 4 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 3 / 3 / 2.5 | 3 / 2.5 / 2 | 3 / 2.5 / 2 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 7.172 / 6.564 / 6.884 | 6.373 / 5.898 / 6.224 | 5.975 / 5.579 / 5.933 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.95 / 4.511 / 4.03 | 4.753 / 4.316 / 3.841 | 4.669 / 4.111 / 3.546 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 8.124 / 8.594 / 9.852 | 7.338 / 7.901 / 9.357 | 6.754 / 7.227 / 8.349 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 4.948 / 4.679 / 4.269 | 4.752 / 4.485 / 4.08 | 4.678 / 4.34 / 3.854 |
| Running Current amps (Cooling / Heating) | 3 / 4 | 3.8 / 4.8 | 4.8 / 6.1 |
| Moisture Removal l/hr | 1.3 | 1.8 | 2.1 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 40 / 22 | 40 / 22 | 44 / 22 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 41 / 22 | 43 / 22 | 43 / 22 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 43 / 47 | 44 / 49 | 47 / 50 |
| Outdoor Sound Power dBA | 58 | 58 | 62 |
| Air Circulation (Indoor - High Fan) Cooling l/sec | 158 | 158 | 181 |
| Air Circulation (Indoor - High Fan) Heating l/sec | 167 | 181 | 181 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 600 x 740 x 200 | 600 x 740 x 200 | 600 x 740 x 200 |
| Indoor Unit Weight kg | 14.00 | 14.00 | 14.00 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 542 x 799 x 290 | 632 x 799 x 290 | 632 x 799 x 290 |
| Outdoor Unit Weight kg | 31.00 | 38.00 | 38.00 |
| Piping Connects mm Ø (Liquid / Gas) | 6.35 / 9.52 | 6.35 / 9.52 | 6.35 / 9.52 |
| Pipe Length m (Max (Precharged)) | 20 (15) | 20 (15) | 20 (15) |
| Max Height Difference m | 15 | 15 | 15 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 46 | -10 to 46 | -10 to 46 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 | -15 to 24 | -15 to 24 |
| Refrigerant Type | R32 | R32 | R32 |
| Refrigerant Amount g | - | - | - |
Source: GENERAL Australia (Fujitsu), Floor Console range page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Fujitsu Floor/Ceiling Dual Console
A console unit that can be installed on the floor or on the ceiling, depending on the room.
- Features listed by the manufacturer: 10°C Heat Operation, All DC, Auto Restart, Auto Shut Louvre, Auto Changeover, Automatic Air Flow Adjustment, Automatic Louvre, Blue Fin Heat Exchanger, Double Swing Automatic, Economy Mode, Program Timer, Right / Left Swing Louvre, Sleep Timer, Up/Down Swing Louvre, Weekly Timer
- Compatible controller options listed: AR-RAH2E, UTY-RNNYN, UTY-RVNYN, UTY-RHRY, UTY-RSRY, UTY-RNRYZ3, UTY-LNHY
Official Floor/Ceiling Dual Console brochure (GENERAL Australia on Issuu) | Official range page
A specification table is not published on the official Floor/Ceiling Dual Console page; please refer to the brochure or ask us for the model details.
How we install a Fujitsu split system in Melbourne
- Enquiry and assessment. We discuss the rooms you want to heat and cool, then assess the home, including room sizes, insulation, windows and orientation, and where the indoor and outdoor units can go.
- Recommendation and written quote. We recommend a Fujitsu split system range and capacity that suits the home and explain the options before you commit.
- Installation. Our team installs the indoor and outdoor units, runs the refrigerant pipework and condensate drain, and completes the electrical connection as required by Victorian regulations.
- Commissioning and handover. We test heating and cooling operation, set up the controller and show you how to use the system and look after the filters.
- Ongoing service. Regular maintenance keeps the system running efficiently. See our maintenance services.
Manufacturer warranty
Fujitsu air conditioners in Australia are supplied by GENERAL Australia (formerly Fujitsu General Australia). The company changed its name on 1 January 2026 and continues to market products under the Fujitsu and General Airstage brands (source). Its official website is now generalairstage.com.au.
GENERAL Australia states that it "provides a 5 year full parts and labour warranty for all domestic air conditioning systems sold in Australia" (GENERAL Australia warranty information). Conditions are set out in the manufacturer's warranty card. We register the details of your installation and can assist if a warranty claim is needed.
Victorian Energy Upgrades
EZYAIR is a Victorian Energy Upgrades (VEU) accredited provider (accreditation A2261). If you are replacing an older heater with an efficient reverse cycle system, ask us whether your project may be eligible for a VEU discount. Eligibility depends on the existing heater, the new product and the program rules at the time. Learn more on our Victorian Energy Upgrades page.
You can see a range of wall hung, cassette, ducted, bulkhead and floor console units on display, many of them operational, at our Burwood showroom at 49 Huntingdale Rd, Burwood VIC 3125.
Related pages
- Fujitsu air conditioning in Melbourne (overview)
- Fujitsu ducted air conditioning
- Fujitsu multi split systems
- Split system installation in Melbourne
- Fujitsu products in our store
- Split system service and maintenance
Fujitsu split system FAQs
What size Fujitsu split system do I need?
The right capacity depends on the room size, ceiling height, insulation, windows and orientation. Fujitsu wall mounted models range from 2.5 kW to 9.5 kW cooling. We assess the room before recommending a size, so the system is neither undersized for Melbourne winters nor oversized.
Which Fujitsu split systems have Wi-Fi control?
GENERAL Australia states that the Lifestyle Next range includes the anywAiR Wi-Fi adaptor II as standard. For other ranges, ask us about the controller and Wi-Fi options listed for the model you are considering.
How long does a Fujitsu split system installation take?
A standard back to back wall split installation is usually completed within a day. More complex installations, such as long pipe runs or difficult outdoor unit locations, can take longer. We confirm the details when we quote.
What warranty applies to Fujitsu split systems?
GENERAL Australia states that it provides a 5 year full parts and labour warranty for all domestic air conditioning systems sold in Australia. Conditions are set out in the manufacturer's warranty card.