Mitsubishi Electric Split Systems Melbourne
A Mitsubishi Electric split system pairs one indoor unit with one outdoor unit to heat and cool a single room or open living area. EZYAIR supplies and installs Mitsubishi Electric wall mounted, floor console and ceiling cassette split systems across Melbourne on request.
Who a Mitsubishi Electric split system suits
Split systems suit Melbourne bedrooms, living areas, home offices and extensions where one room needs efficient heating in winter and cooling in summer. If several rooms need conditioning, a Mitsubishi Electric multi split system or Mitsubishi Electric ducted system may suit better.
Current Mitsubishi Electric split system ranges
The following residential wall mounted, floor console and ceiling cassette ranges are listed on Mitsubishi Electric Australia's website at the time of writing (October 2026).
- Mitsubishi Electric MSZ-AP Series
- Mitsubishi Electric MSZ-AP Mini
- Mitsubishi Electric MSZ-LN Series
- Mitsubishi Electric MSZ-EF Series
- Mitsubishi Electric MSZ-GS Series
- Mitsubishi Electric MSZ-AS90
- Mitsubishi Electric MSY-GW Series (cooling only)
- Mitsubishi Electric MSY-GY90 (cooling only)
- Mitsubishi Electric MFZ-KW Series floor console
- Mitsubishi Electric MLZ-KP Series 1-way cassette
- Mitsubishi Electric SLZ-M Series 4-way cassette
EZYAIR is an independent air conditioning installer. We supply and install the systems below on request; availability of individual models is confirmed at quote stage. Product information on this page is copied from Mitsubishi Electric Australia's official product pages, with links to the official brochures. Figures are as published by the manufacturer (dash characters in ranges are shown as hyphens). Where a figure is not published it is not shown. Tables scroll sideways on smaller screens.
Mitsubishi Electric MSZ-AP Series
A wall mounted reverse cycle range for single rooms and compact homes, with a Quiet Mode setting and capacities from 2.5 kW to 7.8 kW (cooling, rated).
- Key points listed by Mitsubishi Electric: Capacity Range: 2.5 kW - 7.8 kW; Quiet Operation; Heating and cooling; Dual Barrier Coating; Night Mode
Official Mitsubishi Electric Split Systems brochure (PDF) | Official MSZ-AP Series flyer (PDF) | Official range page
Notes published with the table: *1 The Capacity (rated), Total Input (rated) and Running Current (rated) are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1 Cooling: Indoor 27°CDB/19°CWB, Outdoor 35°CDB/24°CWB Heating: Indoor 20°CDB/15°CWB, Outdoor 7°CDB/6°CWB *2 ZERL (Residential) refers to ‘Zoned Energy Rating Label’ residential star rating based on GEMS 2019 Determination. *3 Cooling and Heating have slightly different air volumes. The table shows absolute minimum and maximum air volumes of the unit. *4 Sound Pressure Level measured in anechoic room at 1m.
Specifications: MSZ-AP Series (MSZ-AP25 to AP80), reverse cycle (7 models)
| Indoor Unit | MSZ-AP25VGKD2 | MSZ-AP35VGKD2 | MSZ-AP42VGKD2 | MSZ-AP50VGKD2 | MSZ-AP60VGKD2 | MSZ-AP71VGKD2 | MSZ-AP80VGKD2 |
|---|---|---|---|---|---|---|---|
| Outdoor Unit | MUZ-AP25VGD2 | MUZ-AP35VGD2 | MUZ-AP42VGD2 | MUZ-AP50VGD2 | MUZ-AP60VGD2 | MUZ-AP71VGD2 | MUZ-AP80VGD2 |
| Refrigerant | R32 | R32 | R32 | R32 | R32 | R32 | R32 |
| Cooling Capacity [Rated]*1 kW | 2.5 | 3.5 | 4.2 | 5 | 6 | 7.1 | 7.8 |
| Cooling Capacity [Min-Max] kW | 1.10 - 3.60 | 1.10 - 4.10 | 0.90 - 4.80 | 1.40 - 6.20 | 1.40 - 7.30 | 2.00 - 8.70 | 2.00 - 9.20 |
| Cooling Total Input [Rated]*1 kW | 0.5 | 0.87 | 1.19 | 1.32 | 1.59 | 2.01 | 2.36 |
| Cooling Total Input [Min-Max] kW | 0.21 - 0.99 | 0.21 - 1.18 | 0.15 - 1.90 | 0.30 - 2.23 | 0.24 - 2.35 | 0.43 - 3.03 | 0.43 - 3.20 |
| Cooling EER | 5 | 4.02 | 3.53 | 3.79 | 3.77 | 3.53 | 3.31 |
| Cooling AEER | 4.97 | 4.01 | 3.52 | 3.78 | 3.77 | 3.53 | 3.3 |
| Cooling TCSPF (Residential) Hot | 7.85 | 6.64 | 5.79 | 6.05 | 6.04 | 5.04 | 5 |
| Cooling TCSPF (Residential) Average | 7.31 | 6.19 | 5.53 | 5.69 | 5.8 | 4.81 | 4.77 |
| Cooling TCSPF (Residential) Cold | 7.61 | 6.64 | 5.9 | 6.1 | 6.16 | 5.08 | 5.08 |
| Cooling ZERL (Residential) Star Rating*2 Hot | 6 | 5 | 4 | 4.5 | 4.5 | 3.5 | 3.5 |
| Cooling ZERL (Residential) Star Rating*2 Average | 5.5 | 4.5 | 4 | 4 | 4 | 3 | 3 |
| Cooling ZERL (Residential) Star Rating*2 Cold | 6 | 5 | 4 | 4.5 | 4.5 | 3.5 | 3.5 |
| Cooling Running Current [Rated]*3 A | 2.6 | 4.1 | 5.3 | 5.9 | 7.1 | 8.8 | 10.8 |
| Cooling Sound Pressure Level*4 In [Quiet-SHi] dBA | 19 - 24 - 31 - 38 - 44 | 19 - 24 - 31 - 38 - 45 | 26 - 29 - 35 - 40 - 46 | 28 - 33 - 39 - 44 - 49 | 29 - 37 - 41 - 45 - 48 | 30 - 37 - 41 - 45 - 49 | 30 - 37 - 41 - 45 - 53 |
| Cooling Sound Pressure Level*4 Out (PWL) dBA | 46 (59) | 50 (64) | 51 (65) | 54 (69) | 56 (69) | 56 (69) | 56 (69) |
| Cooling Air Volume (In) [Quiet-SHi] (Speeds) L/s | 82 - 205 (5) | 82 - 223 (5) | 90 - 223 (5) | 100 - 258 (5) | 157 - 315 (5) | 160 - 310 (5) | 160 - 342 (5) |
| Heating Capacity [Rated]*1 kW | 3.2 | 3.7 | 5.4 | 6 | 6.8 | 8 | 9 |
| Heating Capacity [Min-Max] kW | 1.30 - 5.00 | 1.30 - 5.10 | 1.30 - 6.00 | 1.40 - 8.00 | 2.00 - 8.60 | 2.20 - 9.90 | 2.20 - 11.00 |
| Heating Total Input [Rated]*1 kW | 0.67 | 0.82 | 1.43 | 1.62 | 1.65 | 2.09 | 2.55 |
| Heating Total Input [Min-Max] kW | 0.35 - 1.40 | 0.35 - 1.42 | 0.26 - 1.90 | 0.30 - 3.00 | 0.30 - 2.60 | 0.42 - 3.25 | 0.42 - 3.65 |
| Heating COP | 4.78 | 4.51 | 3.78 | 3.7 | 4.12 | 3.83 | 3.53 |
| Heating ACOP | 4.75 | 4.49 | 3.77 | 3.7 | 4.11 | 3.82 | 3.53 |
| Heating HSPF (Residential) Hot | 5.48 | 5.65 | 5.05 | 5.35 | 4.91 | 4.76 | 4.68 |
| Heating HSPF (Residential) Average | 4.99 | 5.01 | 4.35 | 4.38 | 4.42 | 4.25 | 4.07 |
| Heating HSPF (Residential) Cold | 4.59 | 4.51 | 3.88 | 3.9 | 4.01 | 3.76 | 3.54 |
| Heating ZERL (Residential) Star Rating*2 Hot | 3.5 | 4 | 3.5 | 3.5 | 3 | 3 | 3 |
| Heating ZERL (Residential) Star Rating*2 Average | 3 | 3.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 |
| Heating ZERL (Residential) Star Rating*2 Cold | 3 | 3 | 2 | 2 | 2.5 | 2 | 2 |
| Heating Running Current [Rated]*3 A | 3.3 | 3.8 | 6.3 | 7.1 | 7.4 | 9.1 | 11.3 |
| Heating Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 18 - 25 - 31 - 38 - 42 | 19 - 25 - 31 - 38 - 45 | 26 - 29 - 35 - 40 - 46 | 28 - 33 - 38 - 43 - 48 | 30 - 37 - 41 - 45 - 48 | 30 - 37 - 41 - 45 - 51 | 30 - 37 - 41 - 45 - 51 |
| Heating Sound Pressure Level Out (PWL) dBA | 49 (59) | 50 (64) | 52 (65) | 56 (69) | 57 (69) | 55 (69) | 55 (69) |
| Heating Air Volume (In) [Quiet-SHi] L/s | 82 - 190 | 82 - 215 | 88 - 233 | 93 - 268 | 180 - 338 | 170 - 320 | 170 - 320 |
| Max. Running Current A | 7.1 | 7.1 | 10 | 13.9 | 14 | 16.4 | 16.5 |
| Indoor Unit Input [Rated] (Cooling/Heating) W | 23/19 | 29/26 | 29/33 | 43/43 | 41/45 | 42/45 | 55/45 |
| Indoor Unit Dimensions [HxWxD] mm | 299 x 798 x 219 | 299 x 798 x 219 | 299 x 798 x 219 | 299 x 798 x 219 | 325 x 1100 x 257 | 325 x 1100 x 257 | 325 x 1100 x 257 |
| Indoor Unit Weight kg | 10.5 | 10.5 | 10.5 | 10.5 | 16 | 17 | 17 |
| Outdoor Unit Dimensions [HxWxD] mm | 550 x 800 x 285 | 550 x 800 x 285 | 550 x 800 x 285 | 714 x 800 x 285 | 714 x 800 x 285 | 880 x 840 x 330 | 880 x 840 x 330 |
| Outdoor Unit Weight kg | 35 | 35 | 36 | 41 | 41 | 53 | 53 |
| Outdoor Unit Breaker Size A | 10 | 10 | 10 | 16 | 16 | 20 | 20 |
| Piping Diameter [Liquid/Gas] mm | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø12.70 | ø6.35/ø12.70 | ø6.35/ø12.70 | ø6.35/ø12.70 |
| Piping Max. Length/Height m | 20/12 | 20/12 | 20/12 | 20/12 | 30/15 | 30/15 | 30/15 |
| Guaranteed Operating Range [Outdoor] Cooling °C | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 |
| Guaranteed Operating Range [Outdoor] Heating °C | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 |
| Refrigerant Amount [Pre-Charged] kg | 0.7 | 0.7 | 0.7 | 1 | 1.05 | 1.5 | 1.5 |
| System model name | MSZAP25VGKD2KIT | MSZAP35VGKD2KIT | MSZAP42VGKD2KIT | MSZAP50VGKD2KIT | MSZAP60VGKD2KIT | MSZAP71VGKD2KIT | MSZAP80VGKD2KIT |
Source: Mitsubishi Electric Australia, MSZ-AP Series product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Mitsubishi Electric MSZ-AP Mini
A compact wall mounted reverse cycle unit only 250 mm high, which Mitsubishi Electric describes as ideal for bedrooms and home offices and small enough to fit above doorways.
- Key points listed by Mitsubishi Electric: Capacity: 2 kW; Compact design - Only 250 mm high; Heating and cooling; Ideal for bedrooms and home offices; Small enough to fit above doorways
Official Mitsubishi Electric Split Systems brochure (PDF) | Official range page
Notes published with the table: *1 The Capacity (rated), Total Input (rated) and Running Current (rated) are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1 Cooling: Indoor 27°CDB/19°CWB, Outdoor 35°CDB/24°CWB Heating: Indoor 20°CDB/15°CWB, Outdoor 7°CDB/6°CWB *2 ZERL (Residential) refers to ‘Zoned Energy Rating Label’ residential star rating based on GEMS 2019 Determination. *3 Cooling and Heating have slightly different air volumes. The table shows absolute minimum and maximum air volumes of the unit. *4 Sound Pressure Level measured in anechoic room at 1m.
Specifications: MSZ-AP Mini, reverse cycle (1 models)
| Indoor Unit | MSZ-AP20VGD2 |
|---|---|
| Outdoor Unit | MUZ-AP20VGD2 |
| Refrigerant | R32 |
| Cooling Capacity [Rated]*1 kW | 2 |
| Cooling Capacity [Min-Max] kW | 0.60 - 2.70 |
| Cooling Total Input [Rated]*1 kW | 0.46 |
| Cooling Total Input [Min-Max] kW | 0.23 - 1.16 |
| Cooling EER | 4.35 |
| Cooling AEER | 4.31 |
| Cooling TCSPF (Residential) Hot | 6.31 |
| Cooling TCSPF (Residential) Average | 5.93 |
| Cooling TCSPF (Residential) Cold | 6.11 |
| Cooling ZERL (Residential) Star Rating*2 Hot | 4.5 |
| Cooling ZERL (Residential) Star Rating*2 Average | 4 |
| Cooling ZERL (Residential) Star Rating*2 Cold | 4.5 |
| Cooling Running Current [Rated]*3 A | 2.6 |
| Cooling Sound Pressure Level*4 In [Quiet-SHi] dBA | 21 - 26 - 30 - 35 - 42 |
| Cooling Sound Pressure Level*4 Out (PWL) dBA | 47 (59) |
| Cooling Air Volume (In) Quiet - Shi (Speeds) L/s | 58 - 115 (5) |
| Heating Capacity [Rated]*1 kW | 2.5 |
| Heating Capacity [Min-Max] kW | 0.50 - 3.50 |
| Heating Total Input [Rated]*1, 5 kW | 0.6 |
| Heating Total Input [Min-Max] kW | 0.25 - 1.20 |
| Heating COP | 4.17 |
| Heating ACOP | 4.14 |
| Heating HSPF (Residential) Hot | 4.61 |
| Heating HSPF (Residential) Average | 4.28 |
| Heating HSPF (Residential) Cold | 3.94 |
| Heating ZERL (Residential) Star Rating*2 Hot | 3 |
| Heating ZERL (Residential) Star Rating*2 Average | 2.5 |
| Heating ZERL (Residential) Star Rating*2 Cold | 2 |
| Heating Running Current [Rated]*3 A | 3.2 |
| Heating Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 21 - 26 - 30 - 35 - 42 |
| Heating Sound Pressure Level Out (PWL) dBA | 48 (61) |
| Heating Air Volume (In) [Quiet-SHi] L/s | 62 - 122 |
| Max. Running Current A | 7.1 |
| Indoor Unit Input [Rated] (Cooling/Heating) W | 19/19 |
| Indoor Unit Dimensions [HxWxD] mm | 250 x 760 x 178 |
| Indoor Unit Weight kg | 8.2 |
| Outdoor Unit Dimensions [HxWxD] mm | 550 x 800 x 285 |
| Outdoor Unit Weight kg | 31 |
| Outdoor Unit Breaker Size A | 10 |
| Piping Diameter [Liquid/Gas] mm | ø6.35/ø9.52 |
| Piping Max. Length/Height m | 20/12 |
| Guaranteed Operating Range [Outdoor] Cooling °C | -10 ~ 46 |
| Guaranteed Operating Range [Outdoor] Heating °C | -15 ~ 24 |
| Refrigerant Amount [Pre-Charged] kg | 0.55 |
| System model name | MSZAP25VGKD2KIT |
Source: Mitsubishi Electric Australia, MSZ-AP Mini product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Mitsubishi Electric MSZ-LN Series
A premium wall mounted range in Pearl White, Onyx Black and Ruby Red, with a Plasma Quad Plus filter and built in Wi-Fi control listed as standard.
- Key points listed by Mitsubishi Electric: Capacity Range: 2.5 - 6.0 kW; Plasma Quad Plus Filter standard; Dual split vane technology; Built-in Wi-Fi Control; Vertical & Horizontal Swing
Official Mitsubishi Electric Split Systems brochure (PDF) | Official MSZ-LN Series flyer (PDF) | Official range page
Notes published with the table: *1 The Capacity (rated), Total Input (rated) and Running Current (rated) are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1 Cooling: Indoor 27°CDB/19°CWB, Outdoor 35°CDB/24°CWB Heating: Indoor 20°CDB/15°CWB, Outdoor 7°CDB/6°CWB *2 ZERL (Residential) refers to ‘Zoned Energy Rating Label’ residential star rating based on GEMS 2019 Determination. *3 Rated Load Amps (RLA) is based on nominal conditions. Use Maximum Circuit Amps (MCA) for power supply infrastructural sizing, etc.
Specifications: MSZ-LN Series, reverse cycle (4 models)
| Indoor unit | MSZ-LN25VGD(V/B/R) | MSZ-LN35VGD(V/B/R) | MSZ-LN50VGD(V/B/R) | MSZ-LN60VGD(V/B/R) |
|---|---|---|---|---|
| Outdoor unit | MUZ-LN25VGD | MUZ-LN35VGD | MUZ-LN50VGD | MUZ-LN60VGD |
| Refrigerant | R32 | |||
| Cooling Capacity [Rated]*1 kW | 2.5 | 3.5 | 5 | 6.1 |
| Cooling Capacity [Min-Max] kW | 1.00 - 3.50 | 0.80 - 4.00 | 1.00 - 6.00 | 1.40 - 6.90 |
| Cooling Total Input [Rated]*1 kW | 0.49 | 0.82 | 1.38 | 1.7 |
| Cooling Total Input [Min-Max] kW | 0.18 - 0.90 | 0.16 - 1.18 | 0.19 - 2.33 | 0.27 - 2.73 |
| Cooling EER | 5.1 | 4.27 | 3.62 | 3.59 |
| Cooling AEER | 5.07 | 4.25 | 3.61 | 3.58 |
| Cooling TCSPF (Residential) Hot | 6.92 | 6.08 | 5.32 | 4.89 |
| Cooling TCSPF (Residential) Average | 6.48 | 5.75 | 5.07 | 4.64 |
| Cooling TCSPF (Residential) Cold | 6.74 | 6.05 | 5.38 | 4.87 |
| Cooling ZERL (Residential) Star Rating*2 Hot | 5 | 4.5 | 3.5 | 3 |
| Cooling ZERL (Residential) Star Rating*2 Average | 4.5 | 4 | 3.5 | 3 |
| Cooling ZERL (Residential) Star Rating*2 Cold | 5 | 4.5 | 3.5 | 3 |
| Cooling Running Current [Rated]*3 A | 2.7 | 3.8 | 6.3 | 7.8 |
| Cooling Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 19 - 23 - 29 - 36 - 42 | 19 - 24 - 29 - 36 - 43 | 27 - 31 - 35 - 39 - 46 | 29 - 37 - 41 - 45 - 49 |
| Cooling Sound Pressure Level Out (PWL) dBA | 46 (60) | 49 (61) | 51 (64) | 55 (65) |
| Cooling Air Volume (In) [Quiet-SHi] L/s | 78 - 207 | 78 - 217 | 95 - 232 | 118 - 262 |
| Heating Capacity [Rated]*1 kW | 3.2 | 4 | 6 | 6.8 |
| Heating Capacity [Min-Max] kW | 0.70 - 5.40 | 1.00 - 6.30 | 1.00 - 8.20 | 1.80 - 10.0 |
| Heating Total Input [Rated]*1 kW | 0.6 | 0.82 | 1.48 | 1.75 |
| Heating Total Input [Min-Max] kW | 0.15 - 1.50 | 0.17 - 1.88 | 0.17 - 3.00 | 0.33 - 3.62 |
| Heating COP | 5.33 | 4.88 | 4.05 | 3.89 |
| Heating ACOP | 5.3 | 4.86 | 4.04 | 3.88 |
| Heating HSPF (Residential) Hot | 5.54 | 5.42 | 4.75 | 4.73 |
| Heating HSPF (Residential) Average | 5.25 | 5.03 | 4.32 | 4.26 |
| Heating HSPF (Residential) Cold | 4.93 | 4.62 | 3.87 | 3.86 |
| Heating ZERL (Residential) Star Rating*2 Hot | 4 | 3.5 | 3 | 3 |
| Heating ZERL (Residential) Star Rating*2 Average | 3.5 | 3.5 | 2.5 | 2.5 |
| Heating ZERL (Residential) Star Rating*2 Cold | 3 | 3 | 2 | 2 |
| Heating Running Current [Rated]*3 A | 3.4 | 3.8 | 6.8 | 7.53 |
| Heating Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 19 - 24 - 29 - 38 - 45 | 19 - 24 - 29 - 38 - 45 | 25 - 29 - 35 - 43 - 47 | 29 - 37 - 41 - 45 - 49 |
| Heating Sound Pressure Level Out (PWL) dBA | 49 (61) | 50 (62) | 54 (66) | 55 (69) |
| Heating Air Volume (In) [Quiet-SHi] L/s | 75 - 232 | 75 - 232 | 90 - 262 | 108 - 262 |
| Max. Running Current A | 7.1 | 9.9 | 13.9 | 15.2 |
| Input [Rated] (Cooling/Heating) W | 20/27 | 23/27 | 29/34 | 40/40 |
| Indoor Unit Dimensions [H×W×D] mm | 307 x 890 x 233 | 307 x 890 x 233 | 307 x 890 x 233 | 307 x 890 x 233 |
| Indoor Unit Weight kg | 15.5 | 15.5 | 16 | 16 |
| Outdoor Unit Dimensions [H×W×D] mm | 550 x 800 x 285 | 550 x 800 x 285 | 714 x 800 x 285 | 880 x 840 x 330 |
| Outdoor Unit Weight kg | 33 | 34 | 40 | 53 |
| Outdoor Unit Breaker Size A | 10 | 10 | 16 | 16 |
| Piping Diameter [Liquid/Gas] mm | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø12.70 |
| Piping Max. Length/Height m | 20/12 | 20/12 | 30/12 | 30/15 |
| Guaranteed Operating Range [Outdoor] Cooling °C | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 |
| Guaranteed Operating Range [Outdoor] Heating °C | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 |
| Refrigerant Amount [Pre-Charged] kg | 0.8 | 0.85 | 1.25 | 1.45 |
| System model name Colour Pearl White | MLN25VGDVA1KIT | MLN35VGDVA1KIT | MLN50VGDVA1KIT | MLN60VGDVA1KIT |
| System model name Colour Onyx Black | MLN25VGDBA1KIT | MLN35VGDBA1KIT | MLN50VGDBA1KIT | MLN60VGDBA1KIT |
| System model name Colour Ruby Red | MLN25VGDRA1KIT | MLN35VGDRA1KIT | MLN50VGDRA1KIT | MLN60VGDRA1KIT |
Source: Mitsubishi Electric Australia, MSZ-LN Series product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Mitsubishi Electric MSZ-EF Series
A slim line wall mounted range offered in three colours, with a 7-day programmable controller.
- Key points listed by Mitsubishi Electric: Capacity Range: 2.5 - 5.0 kW; Slim-line in design with 3 colour options; 7-day programmable controller; Quiet 21dB Noise Level in Quiet Mode (EF25/35); Wi-Fi Control
Official Mitsubishi Electric Split Systems brochure (PDF) | Official MSZ-EF Series flyer (PDF) | Official range page
Notes published with the table: *1 The Capacity (rated), Total Input (rated) and Running Current (rated) are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1 Cooling: Indoor 27°CDB/19°CWB, Outdoor 35°CDB/24°CWB Heating: Indoor 20°CDB/15°CWB, Outdoor 7°CDB/6°CWB *2 ZERL (Residential) refers to ‘Zoned Energy Rating Label’ residential star rating based on GEMS 2019 Determination. *3 Rated Load Amps (RLA) is based on nominal conditions. Use Maximum Circuit Amps (MCA) for power supply infrastructural sizing, etc.
Specifications: MSZ-EF Series, reverse cycle (4 models)
| Indoor Unit | MSZ-EF25VGKD(W/B/S)-A1 | MSZ-EF35VGKD(W/B/S)-A1 | MSZ-EF42VGKD(W/B/S)-A1 | MSZ-EF50VGKD(W/B/S)-A1 |
|---|---|---|---|---|
| Outdoor Unit | MUZ-EF25VGD-A1 | MUZ-EF35VGD-A1 | MUZ-EF42VGD-A1 | MUZ-EF50VGD-A1 |
| Refrigerant | R32 | R32 | R32 | R32 |
| Cooling Capacity [Rated]*1 kW | 2.5 | 3.5 | 4.2 | 5 |
| Cooling Capacity [Min-Max] kW | 0.90 - 3.40 | 1.10 - 4.00 | 0.90 - 4.60 | 1.40 - 5.40 |
| Cooling Total Input [Rated]*1 kW | 0.54 | 0.91 | 1.2 | 1.55 |
| Cooling Total Input [Min-Max] kW | 0.23 - 1.15 | 0.21 - 1.50 | 0.15 - 1.93 | 0.30 - 1.98 |
| Cooling EER | 4.63 | 3.85 | 3.5 | 3.23 |
| Cooling AEER | 4.6 | 3.83 | 3.49 | 3.22 |
| Cooling TCSPF (Residential) Hot | 6.08 | 5.29 | 4.73 | 4.77 |
| Cooling TCSPF (Residential) Average | 5.71 | 5.02 | 4.5 | 4.55 |
| Cooling TCSPF (Residential) Cold | 5.91 | 5.25 | 4.7 | 4.84 |
| Cooling ZERL (Residential) Star Rating*2 Hot | 4.5 | 3.5 | 3 | 3 |
| Cooling ZERL (Residential) Star Rating*2 Average | 4 | 3.5 | 3 | 3 |
| Cooling ZERL (Residential) Star Rating*2 Cold | 4 | 3.5 | 3 | 3 |
| Cooling Running Current [Rated]*3 A | 3 | 4.2 | 5.4 | 6.9 |
| Cooling Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 19 - 23 - 29 - 36 - 42 | 21 - 24 - 30 - 36 - 42 | 28 - 31 - 35 - 39 - 43 | 30 - 33 - 36 - 40 - 43 |
| Cooling Sound Pressure Level Out (PWL) dBA | 47 (58) | 49 (62) | 50 (62) | 52 (65) |
| Cooling Air Volume (In) [Quiet-SHi] L/s | 67 - 175 | 67 - 175 | 97 - 187 | 97 - 188 |
| Heating Capacity [Rated]*1 kW | 3.2 | 4 | 5.4 | 5.8 |
| Heating Capacity [Min-Max] kW | 1.00 - 4.20 | 1.30 - 5.10 | 1.30 - 6.30 | 1.40 - 7.50 |
| Heating Total Input [Rated]*1 kW | 0.7 | 0.95 | 1.46 | 1.56 |
| Heating Total Input [Min-Max] kW | 0.23 - 1.17 | 0.21 - 1.33 | 0.26 - 2.05 | 0.30 - 2.64 |
| Heating COP | 4.57 | 4.21 | 3.71 | 3.72 |
| Heating ACOP | 4.55 | 4.2 | 3.7 | 3.71 |
| Heating HSPF (Residential) Hot | 4.77 | 4.5 | 4.58 | 4.44 |
| Heating HSPF (Residential) Average | 4.48 | 4.2 | 4.07 | 4.02 |
| Heating HSPF (Residential) Cold | 4.05 | 3.77 | 3.55 | 3.6 |
| Heating ZERL (Residential) Star Rating*2 Hot | 3 | 3 | 3 | 2.5 |
| Heating ZERL (Residential) Star Rating*2 Average | 2.5 | 2.5 | 2.5 | 2.5 |
| Heating ZERL (Residential) Star Rating*2 Cold | 2.5 | 2 | 2 | 2 |
| Heating Running Current [Rated]*3 A | 3.6 | 4.4 | 6.5 | 7.1 |
| Heating Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 21 - 24 - 29 - 37 - 45 | 21 - 24 - 30 - 38 - 46 | 28 - 30 - 35 - 41 - 48 | 30 - 33 - 37 - 43 - 49 |
| Heating Sound Pressure Level Out (PWL) dBA | 48 (61) | 50 (63) | 51 (64) | 52 (65) |
| Heating Air Volume (In) [Quiet-SHi] L/s | 67 - 198 | 67 - 212 | 92 - 220 | 107 - 243 |
| Max. Running Current A | 7.1 | 7.1 | 10 | 14 |
| Input [Rated] (Cooling/Heating) W | 20/26 | 20/30 | 23/33 | 23/43 |
| Indoor Unit Dimensions [H×W×D] mm | 299 x 885 x 195 | 299 x 885 x 195 | 299 x 885 x 195 | 299 x 885 x 195 |
| Indoor Unit Weight kg | 11.5 | 11.5 | 11.5 | 11.5 |
| Outdoor Unit Dimensions [H×W×D] mm | 550 x 800 x 285 | 550 x 800 x 285 | 550 x 800 x 285 | 714 x 800 x 285 |
| Outdoor Unit Weight kg | 31 | 34 | 35 | 40 |
| Outdoor Unit Breaker Size A | 10 | 10 | 12 | 16 |
| Piping Diameter [Liquid/Gas] mm | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø9.52 |
| Piping Max. Length/Height m | 20/12 | 20/12 | 20/12 | 30/15 |
| Guaranteed Operating Range [Outdoor] Cooling °C | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 |
| Guaranteed Operating Range [Outdoor] Heating °C | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 |
| Refrigerant Amount [Pre-Charged] kg | 0.62 | 0.74 | 0.74 | 1.05 |
| System model name Black | MEF25BKD2KIT | MEF35BKD2KIT | MEF42BKD2KIT | MEF50BKD2KIT |
| System model name Silver | MEF25SKD2KIT | MEF35SKD2KIT | MEF42SKD2KIT | MEF50SKD2KIT |
| System model name White | MEF25WKD2KIT | MEF35WKD2KIT | MEF42WKD2KIT | MEF50WKD2KIT |
Source: Mitsubishi Electric Australia, MSZ-EF Series product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Mitsubishi Electric MSZ-GS Series
A wall mounted reverse cycle range from 2.5 kW to 7.8 kW with a Quick Clean design and blue fin anti-corrosion treatment.
- Key points listed by Mitsubishi Electric: Capacity Range: 2.5 kW - 7.8 kW; Heating and cooling; Quick Clean design; Blue fin anti-corrosion treated; Optional advanced air filtration
Official MSZ-GS Series flyer (PDF) | Official range page
Notes published with the table: *1 Zoned Energy Rating Label - residential air conditioning star rating based on GEMS 2019 Determination. Test conditions are based on AS/NZS3823.1.1. Rating Conditions: *2 Cooling: Indoor 27°C, D.B./19°C, W.B.; Outdoor 35°C, D.B./24°C, W.B. *3 Heating: Indoor 20°C, D.B./15°C, W.B.; Outdoor 7°C, D.B./6°C, W.B. *4 Use Maximum Circuit Amps (MCA) for power supply infrastructure sizing, etc. *5 Optional Air Protection guide required when ambient temperature is lower than -5°C
Specifications: MSZ-GS Series, reverse cycle (6 models)
| Indoor Unit | MSZ-GS25VFD2-A1 | MSZ-GS35VFD2-A1 | MSZ-GS50VFD2-A1 | MSZ-GS60VFD2-A1 | MSZ-GS71VFD2-A1 | MSZ-GS80VFD2-A1 |
|---|---|---|---|---|---|---|
| Outdoor Unit | MUZ-GS25VFD2-A1 | MUZ-GS35VFD2-A1 | MUZ-GS50VFD2-A1 | MUZ-GS60VFD2-A1 | MUZ-GS71VFD2-A1 | MUZ-GS80VFD2-A1 |
| Refrigerant | R32 | R32 | R32 | R32 | R32 | R32 |
| Cooling Capacity [Rated]*2 kW | 2.5 | 3.5 | 5 | 6 | 7.1 | 7.8 |
| Cooling Capacity [Min-Max] kW | 1.10 - 3.00 | 1.10 - 3.70 | 1.40 - 5.50 | 1.40 - 6.80 | 1.40 - 7.30 | 2.00 - 9.00 |
| Cooling Total Input [Rated]*2 kW | 0.59 | 0.95 | 1.39 | 1.66 | 2.19 | 2.4 |
| Cooling Total Input [Min-Max] kW | 0.39 - 0.92 | 0.39 - 1.21 | 0.33 - 1.84 | 0.33 - 2.27 | 0.24 - 2.39 | 0.43 - 3.25 |
| Cooling EER | 4.24 | 3.68 | 3.6 | 3.61 | 3.24 | 3.25 |
| Cooling AEER | 4.12 | 3.62 | 3.55 | 3.58 | 3.22 | 3.23 |
| Cooling ZERL Star Rating*1 Hot | 3.5 | 3.5 | 4.5 | 4 | 3 | 3.5 |
| Cooling ZERL Star Rating*1 Average | 3 | 3 | 3.5 | 3.5 | 3 | 3 |
| Cooling ZERL Star Rating*1 Cold | 3 | 3 | 4 | 3.5 | 3 | 3.5 |
| Cooling Running Current [Rated]*2 A | 2.8 | 4.3 | 6.2 | 7.4 | 9.7 | 10.5 |
| Cooling Sound Pressure Level In [Lo-Mid-Hi-SHi] dBA | 22-30-37-44 | 22-31-40-51 | 33-38-44-49 | 33-38-44-50 | 33-38-44-50 | 33-38-44-53 |
| Cooling Sound Pressure Level Out (PWL) dBA | 47 (60) | 51 (64) | 53 (66) | 53 (66) | 56 (69) | 56 (69) |
| Cooling Air Volume (In) [Lo-SHi] L/s | 63 - 163 | 63 - 223 | 167 - 308 | 167 - 322 | 173 - 317 | 173 - 342 |
| Heating Capacity [Rated]*3 kW | 3.1 | 3.7 | 5.5 | 6.6 | 8.0 | 9.0 |
| Heating Capacity [Min-Max] kW | 1.30 - 3.80 | 1.30 - 4.30 | 1.40 - 6.50 | 2.00 - 7.50 | 2.00 - 8.60 | 2.20 - 10.00 |
| Heating Total Input [Rated]*3 kW | 0.78 | 0.94 | 1.43 | 1.7 | 2.2 | 2.55 |
| Heating Total Input [Min-Max] kW | 0.35 - 1.10 | 0.35 - 1.43 | 0.38 - 1.97 | 0.54 - 2.27 | 0.30 - 2.48 | 0.42 - 3.45 |
| Heating COP | 3.97 | 3.94 | 3.85 | 3.88 | 3.64 | 3.53 |
| Heating ACOP | 3.89 | 3.87 | 3.8 | 3.84 | 3.61 | 3.51 |
| Heating ZERL Star Rating*1 Hot | 3.5 | 2.5 | 3 | 3 | 3 | 3.5 |
| Heating ZERL Star Rating*1 Average | 3 | 2 | 2.5 | 2.5 | 2.5 | 2.5 |
| Heating ZERL Star Rating*1 Cold | 2.5 | 2 | 2.5 | 2 | 2 | 2 |
| Heating Running Current [Rated]*3 A | 3.7 | 4.3 | 6.4 | 7.6 | 10 | 11.9 |
| Heating Sound Pressure Level In [Lo-Mid-Hi-SHi] dBA | 23-30-37-44 | 23-30-37-45 | 33-38-44-49 | 33-38-44-49 | 33-39-45-51 | 33-39-45-51 |
| Heating Sound Pressure Level Out (PWL) dBA | 48 (60) | 51 (64) | 53 (66) | 57 (69) | 56 (69) | 57 (69) |
| Heating Air Volume (In) [Lo-SHi] L/s | 58 - 172 | 58 - 178 | 172 - 308 | 172 - 322 | 177 - 317 | 177 - 317 |
| MCA *4 A | 7.6 | 7.7 | 14 | 14 | 14 | 18 |
| Indoor Unit Input [Rated] (Cooling/Heating) W | 18/20 | 37/22 | 41/45 | 45/45 | 56/45 | 56/45 |
| Indoor Unit Dimensions [H×W×D] mm | 290 x 799 x 232 | 290 x 799 x 232 | 305 x 923 x 250 | 305 x 923 x 250 | 325 x 1100 x 238 | 325 x 1100 x 238 |
| Indoor Unit Weight kg | 8.5 | 8.5 | 12.3 | 12.3 | 15.2 | 15.2 |
| Outdoor Unit Dimensions [H×W×D] mm | 550 x 800 x 285 | 550 x 800 x 285 | 714 x 800 x 285 | 714 x 800 x 285 | 714 x 800 x 285 | 880 x 840 x 330 |
| Outdoor Unit Weight kg | 28 | 28.5 | 41 | 41 | 41 | 53 |
| Outdoor Unit Breaker Size A | 10 | 10 | 16 | 16 | 16 | 20 |
| Piping Diameter [Liquid/Gas] mm | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø12.70 | ø6.35/ø12.70 | ø6.35/ø12.70 | ø6.35/ø12.70 |
| Piping Max. Length/Height m | 20/12 | 30/15 | 30/15 | 30/15 | 30/15 | 30/15 |
| Guaranteed Operating Range [Outdoor] Cooling °C | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 |
| Guaranteed Operating Range [Outdoor] Heating *5 °C | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 |
| Refrigerant Amount [Pre-Charged] kg | 0.45 | 0.55 | 1.05 | 1.05 | 1.05 | 1.5 |
| Pre-Charged Piping m | 10 | 10 | 15 | 15 | 15 | 15 |
| System model name | MGS25VFD2A1KIT | MGS35VFD2A1KIT | MGS50VFD2A1KIT | MGS60VFD2A1KIT | MGS71VFD2A1KIT | MGS80VFD2A1KIT |
Source: Mitsubishi Electric Australia, MSZ-GS Series product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Mitsubishi Electric MSZ-AS90
A 9 kW wall mounted reverse cycle unit for large open living areas, with long and wide airflow operation.
- Key points listed by Mitsubishi Electric: Capacity: 9 kW; Perfect for large open domestic living areas; Heating and cooling; Advanced air filtration; Dual Barrier Coating
Official Mitsubishi Electric Split Systems brochure (PDF) | Official range page
Notes published with the table: *1 The Capacity (rated), Total Input (rated) and Running Current (rated) are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1. Cooling: Indoor 27°CDB/19°CWB, Outdoor 35°CDB/24°CWB. Heating: Indoor 20°CDB/15°CWB, Outdoor 7°CDB/6°CWB *2 ZERL (Residential) refers to ‘Zoned Energy Rating Label’ residential star rating based on GEMS 2019 Determination. *3 Rated Load Amps (RLA) is based on nominal conditions. Use Maximum Circuit Amps (MCA) for power supply infrastructural sizing, etc.
Specifications: MSZ-AS90, reverse cycle (1 models)
| Indoor Unit | MSZ-AS90VGD2 |
|---|---|
| Outdoor Unit | MUZ-AS90VGD2 |
| Refrigerant | R32 |
| Cooling Capacity [Rated]*1 kW | 9 |
| Cooling Capacity [Min-Max] kW | 2.00 - 10.30 |
| Cooling Total Input [Rated]*1 kW | 2.63 |
| Cooling Total Input [Min-Max] kW | 0.43 - 3.98 |
| Cooling EER | 3.42 |
| Cooling AEER | 3.42 |
| Cooling TCSPF (Residential) Hot | 5.13 |
| Cooling TCSPF (Residential) Average | 4.91 |
| Cooling TCSPF (Residential) Cold | 5.25 |
| Cooling ZERL (Residential) Star Rating*2 Hot | 3.5 |
| Cooling ZERL (Residential) Star Rating*2 Average | 3 |
| Cooling ZERL (Residential) Star Rating*2 Cold | 3.5 |
| Cooling Running Current [Rated]*3 A | 12 |
| Cooling Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 30 - 37 - 42 - 48 - 54 |
| Cooling Sound Pressure Level Out (PWL) dBA | 56 (69) |
| Cooling Air Volume (In) [Quiet-SHi] L/s | 168 - 463 |
| Heating Capacity [Rated]*1 kW | 10.3 |
| Heating Capacity [Min-Max] kW | 2.20 - 11.50 |
| Heating Total Input [Rated]*1 kW | 2.7 |
| Heating Total Input [Min-Max] kW | 0.42 - 3.90 |
| Heating COP | 3.81 |
| Heating ACOP | 3.81 |
| Heating HSPF (Residential) Hot | 5.25 |
| Heating HSPF (Residential) Average | 4.35 |
| Heating HSPF (Residential) Cold | 3.68 |
| Heating ZERL (Residential) Star Rating*2 Hot | 3.5 |
| Heating ZERL (Residential) Star Rating*2 Average | 2.5 |
| Heating ZERL (Residential) Star Rating*2 Cold | 2 |
| Heating Running Current [Rated]*3 A | 12.6 |
| Heating Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 32 - 38 - 43 - 47 - 53 |
| Heating Sound Pressure Level Out (PWL) dBA | 56 (69) |
| Heating Air Volume (In) [Quiet-SHi] L/s | 203 - 430 |
| Max. Running Current A | 17.9 |
| Input [Rated] (Cooling/Heating) W | 88/71 |
| Indoor Unit Dimensions [H×W×D] mm | 365 x 1170 x 295 |
| Indoor Unit Weight kg | 20 |
| Outdoor Unit Dimensions [H×W×D] mm | 880 x 840 x 330 |
| Outdoor Unit Weight kg | 53 |
| Outdoor Unit Breaker Size A | 20 |
| Piping Diameter [Liquid/Gas] mm | ø6.35/ø12.70 |
| Piping Max. Length/Height m | 30/15 |
| Guaranteed Operating Range [Outdoor] Cooling °C | -10 ~ 46 |
| Guaranteed Operating Range [Outdoor] Heating °C | -15 ~ 24 |
| Refrigerant Amount [Pre-Charged] kg | 1.6 |
| System model name | MSZAS90VGD3KIT |
Source: Mitsubishi Electric Australia, MSZ-AS90 product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Mitsubishi Electric MSY-GW Series (cooling only)
A cooling only wall mounted range from 2.5 kW to 8.0 kW with a Nano Platinum filter.
- Key points listed by Mitsubishi Electric: Capacity Range: 2.5 - 8.0 kW; Cooling only; Quiet operation; Nano Platinum Filter; Wide & Long Airflow
Official Cooling Only Series flyer (PDF) | Official range page
Notes published with the table: *1 Zoned Energy Rating Label - residential air conditioning star rating based on GEMS 2019 Determination. *2 Rated Load Amps (RLA) is based on nominal conditions. Use Maximum Circuit Amps (MCA) for power supply infrastructure sizing, etc. Test conditions are based on AS/NZS3823.1.1. Only available in Nth QLD, WA & NT. Rating Conditions: *3 Cooling: Indoor 27°C D.B./19°C W.B. Outdoor 35°C D.B./24°C W.B.
Specifications: MSY-GW Series, cooling only (7 models)
| Indoor Unit | MSY-GW25VFD2-A1 | MSY-GW35VFD2-A1 | MSY-GW42VFD2-A1 | MSY-GW50VFD2-A1 | MSY-GW60VFD2-A1 | MSY-GW71VFD2-A1 | MSY-GW80VFD2-A1 |
|---|---|---|---|---|---|---|---|
| Outdoor Unit | MUY-GW25VFD2-A1 | MUY-GW35VFD2-A1 | MUY-GW42VFD2-A1 | MUY-GW50VFD2-A1 | MUY-GW60VFD2-A1 | MUY-GW71VFD2-A1 | MUY-GW80VFD2-A1 |
| Refrigerant | R32 | R32 | R32 | R32 | R32 | R32 | R32 |
| Cooling Capacity [Rated]*3 kW | 2.5 | 3.5 | 4.2 | 4.9 | 6 | 7.1 | 8 |
| Cooling Capacity [Min-Max] kW | 1.10 - 3.40 | 1.10 - 4.10 | 0.90 - 4.80 | 1.50 - 6.00 | 1.50 - 7.20 | 2.40 - 8.70 | 2.40 - 9.20 |
| Cooling Total Input [Rated]*3 kW | 0.58 | 0.87 | 1.18 | 1.24 | 1.58 | 1.83 | 2.27 |
| Cooling Total Input [Min-Max] kW | 0.19 - 0.99 | 0.19 - 1.18 | 0.17 - 1.90 | 0.32 - 2.00 | 0.33 - 2.20 | 0.48 - 3.20 | 0.48 - 3.34 |
| Cooling EER | 4.31 | 4.02 | 3.56 | 3.95 | 3.8 | 3.88 | 3.52 |
| Cooling AEER | 4.19 | 3.95 | 3.51 | 3.9 | 3.76 | 3.84 | 3.5 |
| Cooling TCSPF (Residential) Hot | 6.29 | 7.26 | 5.82 | 6.19 | 6.09 | 6.17 | 5.18 |
| Cooling TCSPF (Residential) Mixed | 5.28 | 6.06 | 5.16 | 5.51 | 5.6 | 5.58 | 4.8 |
| Cooling TCSPF (Residential) Cold | 5.35 | 6.33 | 5.41 | 5.77 | 5.89 | 5.84 | 5.04 |
| Cooling ZERL Star Rating*1 Hot | 4.5 | 5.5 | 4 | 4.5 | 4.5 | 4.5 | 3.5 |
| Cooling ZERL Star Rating*1 Average | 3.5 | 4.5 | 3.5 | 4 | 4 | 4 | 3 |
| Cooling ZERL Star Rating*1 Cold | 3.5 | 4.5 | 3.5 | 4 | 4 | 4 | 3.5 |
| Cooling Running Current [Rated]*2 *3 A | 3.3 | 4.2 | 5.6 | 5.6 | 7.2 | 8.2 | 10.6 |
| Cooling Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 19 - 24 - 31 - 38 - 45 | 19 - 24 - 31 - 38 - 45 | 26 - 29 - 35 - 40 - 46 | 28 - 33 - 38 - 44 - 49 | 29 - 37 - 41 - 45 - 50 | 30 - 37 - 41 - 45 - 51 | 30 - 37 - 41 - 45 - 51 |
| Cooling Sound Pressure Level Out (PWL) dBA | 46 (59) | 50 (62) | 51 (64) | 52 (64) | 55 (67) | 57 (69) | 57 (69) |
| Cooling Air Volume (In) [Quiet-SHi] L/s | 72 - 208 | 72 - 215 | 82 - 218 | 143 - 307 | 113 - 317 | 152 - 345 | 152 - 345 |
| Indoor Unit Dimensions [H×W×D] mm | 290 x 799 x 232 | 290 x 799 x 232 | 290 x 799 x 232 | 305 x 923 x 250 | 305 x 923 x 250 | 325 x 1100 x 238 | 325 x 1100 x 238 |
| Indoor Unit Weight kg | 9.5 | 9.5 | 9.5 | 12.5 | 12.5 | 14.7 | 14.7 |
| Outdoor Unit Dimensions [H×W×D] mm | 550 x 800 x 285 | 550 x 800 x 285 | 550 x 800 x 285 | 550 x 800 x 285 | 714 x 800 x 285 | 880 x 840 x 330 | 880 x 840 x 330 |
| Outdoor Unit Weight kg | 29.5 | 32.5 | 33 | 33 | 39 | 48.5 | 48.5 |
| Piping Diameter [Liquid/Gas] mm | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø12.70 | ø6.35/ø12.70 | ø6.35/ø12.70 | ø6.35/ø12.70 |
| Piping Max. Length/Height m | 20/12 | 20/12 | 20/12 | 20/12 | 20/12 | 30/15 | 30/15 |
| Guaranteed Operating Range [Outdoor] Cooling °C | 21 ~ 46 | 21 ~ 46 | 21 ~ 46 | 21 ~ 46 | 21 ~ 46 | 21 ~ 46 | 21 ~ 46 |
| System model name Wireless controller kit | MSYGW25VFD2KIT | MSYGW35VFD2KIT | MSYGW42VFD2KIT | MSYGW50VFD2KIT | MSYGW60VFD2KIT | MSYGW71VFD2KIT | MSYGW80VFD2KIT |
Source: Mitsubishi Electric Australia, MSY-GW Series Cooling Only product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Mitsubishi Electric MSY-GY90 (cooling only)
A 9 kW cooling only wall mounted unit for large open living areas.
- Key points listed by Mitsubishi Electric: Capacity: 9 kW; Perfect for large open domestic living areas; Cooling only; Nano Platinum Filter; Wide & Long Airflow
Official Cooling Only Series flyer (PDF) | Official range page
Notes published with the table: *1 Zoned Energy Rating Label - residential air conditioning star rating based on GEMS 2019 Determination. *2 Rated Load Amps (RLA) is based on nominal conditions. Use Maximum Circuit Amps (MCA) for power supply infrastructure sizing, etc. Test conditions are based on AS/NZS3823.1.1. Only available in Nth QLD, WA & NT. MSZ-GW/GY indoor, CANNOT be used with MXZ outdoor unit Rating Conditions: *3 Cooling: Indoor 27°C D.B./19°C W.B. Outdoor 35°C D.B./24°C W.B.
Specifications: MSY-GY90, cooling only (1 models)
| Indoor Unit | MSY-GY90VFD2-A1 |
|---|---|
| Outdoor Unit | MUY-GY90VFD2-A1 |
| Refrigerant | R32 |
| Cooling Capacity [Rated]*3 kW | 9 |
| Cooling Capacity [Min-Max] kW | 2.0 - 10.3 |
| Cooling Total Input [Rated]*3 kW | 2.63 |
| Cooling Total Input [Min-Max] kW | 0.43 - 3.98 |
| Cooling EER | 3.42 |
| Cooling AEER | 3.42 |
| Cooling TCSPF (Residential) Hot | 5.13 |
| Cooling TCSPF (Residential) Mixed | 4.91 |
| Cooling TCSPF (Residential) Cold | 5.25 |
| Cooling ZERL Star Rating*1 Hot | 3.5 |
| Cooling ZERL Star Rating*1 Average | 3 |
| Cooling ZERL Star Rating*1 Cold | 3.5 |
| Cooling Running Current [Rated]*2 *3 A | 12 |
| Cooling Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 30 - 36 - 42 - 48 - 54 |
| Cooling Sound Pressure Level Out (PWL) dBA | 56 (69) |
| Cooling Air Volume (In) [Quiet-SHi] L/s | 168 - 463 |
| Indoor Unit Dimensions [H×W×D] mm | 365 x 1170 x 295 |
| Indoor Unit Weight kg | 20 |
| Outdoor Unit Dimensions [H×W×D] mm | 880 x 840 x 330 |
| Outdoor Unit Weight kg | 53 |
| Piping Diameter [Liquid/Gas] mm | ø6.35/ø12.70 |
| Piping Max. Length/Height m | 30/15 |
| Guaranteed Operating Range [Outdoor] Cooling °C | -10 ~ 46 |
| System model name Wireless controller kit | MSYGY90VFD2KIT |
Source: Mitsubishi Electric Australia, MSY-GY90 Cooling Only product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Mitsubishi Electric MFZ-KW Series floor console
A slim floor console from 2.5 kW to 6.1 kW. Mitsubishi Electric notes the removable base allows the indoor unit to be recessed into the wall.
- Key points listed by Mitsubishi Electric: Capacity range: 2.5 kW - 6.1 kW; Rapid heating technology; Multi-flow vane; Unobtrusive recess installation; Quiet operation
Official Mitsubishi Electric Split Systems brochure (PDF) | Official range page
Notes published with the table: *1 The Capacity (rated), Total Input (rated) and Running Current (rated) are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1 Cooling: Indoor 27°CDB/19°CWB, Outdoor 35°CDB/24°CWB Heating: Indoor 20°CDB/15°CWB, Outdoor 7°CDB/6°CWB *2 ZERL (Residential) refers to ‘Zoned Energy Rating Label’ residential star rating based on GEMS 2019 Determination. *3 Rated Load Amps (RLA) is based on nominal conditions. Use Maximum Circuit Amps (MCA) for power supply infrastructural sizing, etc.
Specifications: MFZ-KW Series floor console, reverse cycle (5 models)
| Indoor Unit | MFZ-KW25VGK-A1 | MFZ-KW35VGK-A1 | MFZ-KW42VGK-A1 | MFZ-KW50VGK-A1 | MFZ-KW60VGK-A1 |
|---|---|---|---|---|---|
| Outdoor Unit | MUFZ-KW25VG2-A1 | MUFZ-KW35VG2-A1 | MUFZ-KW42VG2-A1 | MUFZ-KW50VG2-A1 | MUFZ-KW60VG2-A1 |
| Refrigerant | R32 | R32 | R32 | R32 | R32 |
| Cooling Capacity [Rated]*1 kW | 2.5 | 3.5 | 4.2 | 5 | 6.1 |
| Cooling Capacity [Min-Max] kW | 0.70 - 3.40 | 0.70 - 3.80 | 0.70 - 5.00 | 1.00 - 5.70 | 1.00 - 6.50 |
| Cooling Total Input [Rated]*1 kW | 0.57 | 0.87 | 1.11 | 1.32 | 1.73 |
| Cooling Total Input [Min-Max] kW | 0.19 - 0.89 | 0.19 - 1.01 | 0.19 - 1.68 | 0.31 - 1.95 | 0.31 - 2.25 |
| Cooling EER | 4.39 | 4.02 | 3.78 | 3.79 | 3.53 |
| Cooling AEER | 4.32 | 3.98 | 3.75 | 3.76 | 3.51 |
| Cooling TCSPF (Residential) Hot | 5.56 | 5.33 | 4.72 | 4.58 | 4.46 |
| Cooling TCSPF (Residential) Average | 5.09 | 4.96 | 4.43 | 4.32 | 4.22 |
| Cooling TCSPF (Residential) Cold | 5.18 | 5.12 | 4.54 | 4.41 | 4.36 |
| Cooling ZERL (Residential) Star Rating*2 Hot | 4 | 3.5 | 3 | 3 | 2.5 |
| Cooling ZERL (Residential) Star Rating*2 Average | 3.5 | 3 | 2.5 | 2.5 | 2.5 |
| Cooling ZERL (Residential) Star Rating*2 Cold | 3.5 | 3.5 | 3 | 2.5 | 2.5 |
| Cooling Running Current [Rated]*3 A | 2.9 | 4.1 | 5.1 | 5.9 | 7.5 |
| Cooling Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 20 - 26 - 32 - 38 - 44 | 20 - 26 - 32 - 38 - 44 | 20 - 28 - 36 - 43 - 51 | 27 - 31 - 35 - 39 - 44 | 27 - 35 - 39 - 46 - 53 |
| Cooling Sound Pressure Level Out (PWL) dBA | 48 (61) | 48 (61) | 48 (62) | 53 (66) | 53 (66) |
| Cooling Air Volume In [Quiet-SHi] (Speeds) L/s | 65 - 80 - 107 - 135 - 172 | 65 - 80 - 107 - 135 - 172 | 65 - 88 - 125 - 163 - 228 | 102 - 112 - 133 - 155 - 177 | 102 - 133 - 160 - 205 - 250 |
| Heating Capacity [Rated]*1 kW | 3.4 | 4.3 | 5.4 | 5.8 | 6.5 |
| Heating Capacity [Min-Max] kW | 0.23 - 4.60 | 0.23 - 6.00 | 0.23 - 6.70 | 1.20 - 8.20 | 1.20 - 8.80 |
| Heating Total Input [Rated]*1 kW | 0.78 | 1.14 | 1.43 | 1.53 | 1.88 |
| Heating Total Input [Min-Max] kW | 0.13 - 1.35 | 0.13 - 2.38 | 0.13 - 2.40 | 0.37 - 3.30 | 0.37 - 3.43 |
| Heating COP | 4.36 | 3.77 | 3.78 | 3.79 | 3.46 |
| Heating ACOP | 4.31 | 3.74 | 3.75 | 3.77 | 3.44 |
| Heating HSPF (Residential) Hot | 4.62 | 4.59 | 4.67 | 4.67 | 4.64 |
| Heating HSPF (Residential) Average | 4.36 | 4.14 | 4.17 | 4.2 | 4.05 |
| Heating HSPF (Residential) Cold | 4.08 | 3.74 | 3.70 | 3.79 | 3.56 |
| Heating ZERL (Residential) Star Rating*2 Hot | 3 | 3 | 3 | 3 | 3 |
| Heating ZERL (Residential) Star Rating*2 Average | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 |
| Heating ZERL (Residential) Star Rating*2 Cold | 2.5 | 2 | 2 | 2 | 2 |
| Heating Running Current [Rated]*3 A | 3.8 | 5.1 | 6.5 | 6.8 | 8.3 |
| Heating Sound Pressure Level In [Quiet-Lo-Mid-Hi-SHi] dBA | 18 - 25 - 31 - 38 - 44 | 18 - 25 - 31 - 38 - 44 | 18 - 27 - 36 - 44 - 51 | 29 - 35 - 40 - 45 - 50 | 29 - 35 - 41 - 47 - 51 |
| Heating Sound Pressure Level Out (PWL) dBA | 46 (59) | 47 (60) | 47 (61) | 56 (69) | 56 (69) |
| Heating Air Volume In [Quiet-SHi] (Speeds) L/s | 58 - 75 - 102 - 135 - 173 | 58 - 75 - 102 - 135 - 173 | 58 - 83 - 125 - 170 - 235 | 100 - 128 - 157 - 193 - 233 | 100 - 128 - 162 - 208 - 243 |
| Max. Running Current A | 9.9 | 9.9 | 10.1 | 15.3 | 15.4 |
| Input [Rated] (Cooling/Heating) W | 28/28 | 28/28 | 52/53 | 26/52 | 63/59 |
| Indoor Unit Dimensions [H×W×D] mm | 600 x 750 x 215 | 600 x 750 x 215 | 600 x 750 x 215 | 600 x 750 x 215 | 600 x 750 x 215 |
| Indoor Unit Weight kg | 15 | 15 | 15 | 15 | 15 |
| Outdoor Unit Dimensions [H×W×D] mm | 550 x 800 x 285 | 550 x 800 x 285 | 550 x 800 x 285 | 880 x 840 x 330 | 880 x 840 x 330 |
| Outdoor Unit Weight kg | 35 | 35 | 35 | 54 | 54 |
| Outdoor Unit Breaker Size A | 10 | 10 | 12 | 16 | 20 |
| Piping Diameter [Liquid/Gas] mm | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø12.70 | ø6.35/ø12.70 |
| Piping Max. Length/Height m | 20/12 | 20/12 | 20/12 | 30/15 | 30/15 |
| Guaranteed Operating Range [Outdoor] Cooling °C | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 | -10 ~ 46 |
| Guaranteed Operating Range [Outdoor] Heating °C | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 | -15 ~ 24 |
| Refrigerant Amount [Pre-Charged] kg | 1 | 1 | 1 | 1.3 | 1.3 |
| System model name | MKW25VG2A2KIT | MKW35VG2A2KIT | MKW42VG2A2KIT | MKW50VG2A2KIT | MKW60VG2A2KIT |
Source: Mitsubishi Electric Australia, MFZ-KW-VGK Series product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Mitsubishi Electric MLZ-KP Series 1-way cassette
A 1-way ceiling cassette only 185 mm high, from 2.5 kW to 5.0 kW, for discreet installation in tight ceiling spaces.
- Key points listed by Mitsubishi Electric: Capacity Range: 2.5 kW - 5.0 kW; 1-way airflow; Slimline Design - only 185 mm high; Anti-Allergy Enzyme Filter (Optional); Auto Vane Control
Official Mitsubishi Electric Split Systems brochure (PDF) | Official range page
Notes published with the table: *1 The Capacity (rated), Total Input (rated) and Running Current (rated) are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1 Cooling: Indoor 27°CDB/19°CWB, Outdoor 35°CDB/24°CWB Heating: Indoor 20°CDB/15°CWB, Outdoor 7°CDB/6°CWB *2 ZERL (Residential) refers to ‘Zoned Energy Rating Label’ residential star rating based on GEMS 2019 Determination. *3 Rated Load Amps (RLA) is based on nominal conditions. Use Maximum Circuit Amps (MCA) for power supply infrastructural sizing, etc.
Specifications: MLZ-KP Series 1-way ceiling cassette, reverse cycle (3 models)
| Indoor Unit | MLZ-KP25VG-A1 | MLZ-KP35VG-A1 | MLZ-KP50VG-A1 |
|---|---|---|---|
| Outdoor Unit | SUZ-M25VAD2-A | SUZ-M35VAD2-A | SUZ-M50VAD2-A |
| Refrigerant | R32 | R32 | R32 |
| Power Supply [V, Phase, Hz] | 230 V, Single, 50/60 Hz, Outdoor unit supply | ||
| Cooling Capacity [Min - Rated*1 - Max] kW | 1.50 - 2.50 - 3.20 | 1.50 - 3.50 - 4.10 | 2.30 - 5.00 - 5.50 |
| Cooling Total Input [Rated]*1 kW | 0.59 | 0.9 | 1.37 |
| Cooling EER | 4.23 | 3.89 | 3.65 |
| Cooling AEER | 4.07 | 3.8 | 3.59 |
| Cooling TCSPF (Residential) Hot | 5.5 | 5.52 | 4.58 |
| Cooling TCSPF (Residential) Average | 4.57 | 4.84 | 4.18 |
| Cooling TCSPF (Residential) Cold | 4.53 | 4.95 | 4.24 |
| Cooling ZERL (Residential) Star Rating*2 Hot | 3.5 | 4 | 3 |
| Cooling ZERL (Residential) Star Rating*2 Average | 3 | 3 | 2.5 |
| Cooling ZERL (Residential) Star Rating*2 Cold | 3 | 3 | 2.5 |
| Cooling Running Current [Rated]*3 A | 3.7 | 4.7 | 6.8 |
| Cooling Sound Pressure Level In [Slo-Lo-Mid-Hi] dBA | 27 - 31 - 34 - 38 | 27 - 32 - 36 - 40 | 29 - 36 - 41 - 47 |
| Cooling Sound Pressure Level Out (PWL) dBA | 45 (59) | 48 (62) | 48 (64) |
| Cooling Air Volume (In) [Slo-Lo-Mid-Hi] L/s | 100 - 120 - 133 - 147 | 100 - 122 - 140 - 157 | 100 - 138 - 163 - 190 |
| Heating Capacity [Min - Rated*1 - Max] kW | 1.30 - 3.20 - 4.20 | 1.30 - 4.10 - 4.70 | 1.70 - 6.00 - 6.80 |
| Heating Total Input [Rated]*1 kW | 0.79 | 1.13 | 1.83 |
| Heating COP | 4.05 | 3.63 | 3.28 |
| Heating ACOP | 3.93 | 3.56 | 3.24 |
| Heating HSPF (Residential) Hot | 5.06 | 5.06 | 4.49 |
| Heating HSPF (Residential) Average | 4.5 | 4.37 | 3.89 |
| Heating HSPF (Residential) Cold | 3.97 | 3.85 | 3.42 |
| Heating ZERL (Residential) Star Rating*2 Hot | 3.5 | 3.5 | 2.5 |
| Heating ZERL (Residential) Star Rating*2 Average | 3 | 2.5 | 2 |
| Heating ZERL (Residential) Star Rating*2 Cold | 2 | 2 | 1.5 |
| Heating Running Current [Rated]*3 A | 4.3 | 5.1 | 8.1 |
| Heating Sound Pressure Level In [Slo-Lo-Mid-Hi] dBA | 26 - 29 - 34 - 37 | 26 - 32 - 36 - 40 | 26 - 37 - 42 - 48 |
| Heating Sound Pressure Level Out (PWL) dBA | 46 (59) | 48 (63) | 49 (66) |
| Heating Air Volume (In) [Slo-Lo-Mid-Hi] L/s | 100 - 117 - 137 - 153 | 100 - 128 - 147 - 165 | 100 - 147 - 172 - 197 |
| Max. Running Current A | 7.2 | 8.9 | 13.9 |
| Indoor Unit Input [Rated] kW | 0.04 | 0.04 | 0.04 |
| Indoor Unit Dimensions [H×W×D] mm | 185 x 1102 x 360 | 185 x 1102 x 360 | 185 x 1102 x 360 |
| Indoor Unit Panel [H×W×D] mm | 24 x 1200 x 424 | 24 x 1200 x 424 | 24 x 1200 x 424 |
| Indoor Unit Weight (Panel) kg | 15.5 (3.5) | 15.5 (3.5) | 15.5 (3.5) |
| Outdoor Unit Dimensions [H×W×D] mm | 550 x 800 x 285 | 550 x 800 x 285 | 714 x 800 x 285 |
| Outdoor Unit Weight kg | 30 | 35 | 41 |
| Outdoor Unit Breaker Size A | 10 | 10 | 20 |
| Piping Diameter [Liquid/Gas] mm | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø12.70 |
| Piping Max. Length/Height m | 20/12 | 20/12 | 30/30 |
| Guaranteed Operating Range [Outdoor] Cooling °C | -10 ~ 52 | -10 ~ 52 | -15 ~ 52 |
| Guaranteed Operating Range [Outdoor] Heating °C | -10 ~ 24 | -10 ~ 24 | -10 ~ 24 |
| Refrigerant Amount [Pre-Charged] kg | 0.65 | 0.9 | 1.2 |
| System model name | MLZKP25VG2KIT | MLZKP35VG2KIT | MLZKP50VG2KIT |
Source: Mitsubishi Electric Australia, MLZ-KP Series product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
Mitsubishi Electric SLZ-M Series 4-way cassette
A compact 4-way ceiling cassette from 2.5 kW to 6.0 kW, designed to fit 600 mm x 600 mm ceiling grids, with an optional 3D i-See Sensor.
- Key points listed by Mitsubishi Electric: Capacity Range: 2.5 kW - 6.0 kW; 4-way airflow; Compact Design; 3D i-See Sensor (Optional); Built-in drain pump
Official Mitsubishi Electric Split Systems brochure (PDF) | Official Mr Slim Air Conditioning Systems brochure (PDF) | Official range page
Notes published with the table: *1 The Capacity (rated), Total Input (rated) and Running Current (rated) are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1 Cooling: Indoor 27°CDB/19°CWB, Outdoor 35°CDB/24°CWB Heating: Indoor 20°CDB/15°CWB, Outdoor 7°CDB/6°CWB *2 ZERL (Residential) refers to ‘Zoned Energy Rating Label’ residential star rating based on GEMS 2019 Determination. *3 Rated Load Amps (RLA) is based on nominal conditions. Use Maximum Circuit Amps (MCA) for power supply infrastructural sizing, etc.
Specifications: SLZ-M Series 4-way ceiling cassette, reverse cycle (4 models)
| Indoor Unit | SLZ-M25FA3-A | SLZ-M35FA3-A | SLZ-M50FA3-A | SLZ-M60FA3-A |
|---|---|---|---|---|
| Outdoor Unit | SUZ-M25VAD2-A | SUZ-M35VAD2-A | SUZ-M50VAD2-A | SUZ-M60VAD2-A |
| Refrigerant | R32 | R32 | R32 | R32 |
| Power Supply [V, Phase, Hz] | 230 V, Single, 50/60 Hz, Outdoor unit supply | |||
| Cooling Capacity [Min - Rated*1 - Max] kW | 1.50 - 2.50 - 3.50 | 1.50 - 3.50 - 4.00 | 2.30 - 5.00 - 5.50 | 2.30 - 5.60 - 6.70 |
| Cooling Total Input [Rated]*1 kW | 0.62 | 0.93 | 1.49 | 1.64 |
| Cooling EER | 4.03 | 3.76 | 3.36 | 3.41 |
| Cooling AEER | 3.88 | 3.68 | 3.31 | 3.36 |
| Cooling TCSPF (Residential) Hot | 5.01 | 4.98 | 4.34 | 4.47 |
| Cooling TCSPF (Residential) Average | 4.22 | 4.41 | 3.97 | 4.04 |
| Cooling TCSPF (Residential) Cold | 4.17 | 4.47 | 4.06 | 4.12 |
| Cooling ZERL (Residential) Star Rating*2 Hot | 3.5 | 3 | 2.5 | 2.5 |
| Cooling ZERL (Residential) Star Rating*2 Average | 2.5 | 2.5 | 2 | 2.5 |
| Cooling ZERL (Residential) Star Rating*2 Cold | 2.5 | 2.5 | 2.5 | 2.5 |
| Cooling Running Current [Rated]*3 A | 3.7 | 4.7 | 6.8 | 7.6 |
| Cooling Sound Pressure Level In [Lo-Mid-Hi] dBA | 25 - 28 - 31 | 25 - 33 - 39 | 27 - 34 - 39 | 32 - 40 - 43 |
| Cooling Sound Pressure Level Out (PWL) dBA | 45 (59) | 48 (62) | 48 (64) | 49 (65) |
| Cooling Air Volume (In) [Lo-Mid-Hi] L/s | 108 - 125 - 142 | 108 - 150 - 192 | 117 - 150 - 192 | 125 - 192 - 217 |
| Heating Capacity [Min - Rated*1 - Max] kW | 1.30 - 3.00 - 4.10 | 1.30 - 4.00 - 5.00 | 1.70 - 5.00 - 5.50 | 2.50 - 6.00 - 7.60 |
| Heating Total Input [Rated]*1 kW | 0.78 | 1.05 | 1.58 | 1.87 |
| Heating COP | 3.85 | 3.81 | 3.16 | 3.21 |
| Heating ACOP | 3.73 | 3.74 | 3.12 | 3.16 |
| Heating HSPF (Residential) Hot | 4.74 | 4.7 | 4.31 | 4.42 |
| Heating HSPF (Residential) Average | 4.21 | 4.22 | 3.73 | 3.79 |
| Heating HSPF (Residential) Cold | 3.65 | 3.8 | 3.27 | 3.25 |
| Heating ZERL (Residential) Star Rating*2 Hot | 3 | 3 | 2.5 | 2.5 |
| Heating ZERL (Residential) Star Rating*2 Average | 2.5 | 2.5 | 2 | 2 |
| Heating ZERL (Residential) Star Rating*2 Cold | 2 | 2 | 1.5 | 1.5 |
| Heating Running Current [Rated]*3 A | 4.3 | 5.1 | 8.1 | 8.7 |
| Heating Sound Pressure Level In [Lo-Mid-Hi] dBA | 25 - 28 - 31 | 25 - 33 - 39 | 27 - 34 - 39 | 32 - 40 - 43 |
| Heating Sound Pressure Level Out (PWL) dBA | 46 (59) | 48 (63) | 49 (66) | 51 (68) |
| Heating Air Volume (In) [Lo-Mid-Hi] L/s | 108 - 125 - 142 | 108 - 150 - 192 | 117 - 150 - 192 | 125 - 192 - 217 |
| Max. Running Current A | 7 | 8.8 | 13.8 | 15.2 |
| Indoor Unit Input [Rated] kW | 0.02 | 0.03 | 0.03 | 0.04 |
| Indoor Unit Dimensions [H×W×D] mm | 245 x 570 x 570 | 245 x 570 x 570 | 245 x 570 x 570 | 245 x 570 x 570 |
| Indoor Unit Panel [H×W×D] mm | 10 x 625 x 625 | 10 x 625 x 625 | 10 x 625 x 625 | 10 x 625 x 625 |
| Indoor Unit Weight (Panel) kg | 15.0 (3.0) | 15.0 (3.0) | 15.0 (3.0) | 15.0 (3.0) |
| Outdoor Unit Dimensions [H×W×D] mm | 550 x 800 x 285 | 550 x 800 x 285 | 714 x 800 x 285 | 880 x 840 x 330 |
| Outdoor Unit Weight kg | 30 | 35 | 41 | 54 |
| Outdoor Unit Breaker Size A | 10 | 10 | 20 | 20 |
| Piping Diameter [Liquid/Gas] mm | ø6.35/ø9.52 | ø6.35/ø9.52 | ø6.35/ø12.70 | ø6.35/ø15.88 |
| Piping Max. Length/Height m | 20/12 | 20/12 | 30/30 | 30/30 |
| Guaranteed Operating Range [Outdoor] Cooling °C | -10 ~ 52 | -10 ~ 52 | -15 ~ 52 | -15 ~ 52 |
| Guaranteed Operating Range [Outdoor] Heating °C | -10 ~ 24 | -10 ~ 24 | -15 ~ 24 | -15 ~ 24 |
| Refrigerant Amount [Pre-Charged] kg | 0.65 | 0.9 | 1.2 | 1.25 |
| System model name Wired controller system | SLZM25VA2MAKIT | SLZM35VA2MAKIT | SLZM50VA2MAKIT | SLZM60VA2MAKIT |
| System model name Wireless controller system | SLZM25VA2LKIT | SLZM35VA2LKIT | SLZM50VA2LKIT | SLZM60VA2LKIT |
Source: Mitsubishi Electric Australia, SLZ-M Series product page. Specifications are reproduced as published by the manufacturer and may change. Please confirm current model details with us before purchase.
How we install a Mitsubishi Electric split system in Melbourne
- Enquiry and assessment. We discuss the rooms you want to heat and cool, then assess the home, including room sizes, insulation, windows and orientation, and where the indoor and outdoor units can go.
- Recommendation and written quote. We recommend a Mitsubishi Electric range and capacity that suits the home and explain the options before you commit.
- Installation. Our team installs the indoor and outdoor units, runs the refrigerant pipework and condensate drain, and completes the electrical connection as required by Victorian regulations.
- Commissioning and handover. We test heating and cooling operation, set up the controller and show you how to use the system and look after the filters.
- Ongoing service. Regular maintenance keeps the system running efficiently. See our maintenance services.
Manufacturer warranty
Mitsubishi Electric Australia states that "Mitsubishi Electric M & S series models come with a warranty period of 5 years on parts and labour for residential application", and its warranty table lists 5 Years Parts & Labour for P Series (Mr Slim), M Series, S Series and City Multi air conditioners. Conditions and exclusions are set out on the Mitsubishi Electric Australia warranty information page.
Victorian Energy Upgrades
EZYAIR is a Victorian Energy Upgrades (VEU) accredited provider (accreditation A2261). If you are replacing an older heater with an efficient reverse cycle system, ask us whether your project may be eligible for a VEU discount. Eligibility depends on the existing heater, the new product and the program rules at the time. Learn more on our Victorian Energy Upgrades page.
You can see a range of wall hung, cassette, ducted, bulkhead and floor console units on display, many of them operational, at our Burwood showroom at 49 Huntingdale Rd, Burwood VIC 3125.
Related pages
- Mitsubishi Electric air conditioning in Melbourne (overview)
- Mitsubishi Electric ducted air conditioning
- Mitsubishi Electric multi split systems
- Split system installation in Melbourne
- Split system service and maintenance
Mitsubishi Electric split system FAQs
Which Mitsubishi Electric split system suits a Melbourne bedroom?
For a typical bedroom, the compact MSZ-AP Mini and the smaller MSZ-AP, MSZ-EF and MSZ-LN models are common choices. The right capacity depends on room size, insulation, windows and orientation, so we assess the room before recommending a model.
Do Mitsubishi Electric split systems have Wi-Fi?
Mitsubishi Electric lists built in Wi-Fi control as standard on the MSZ-LN Series. For several other ranges it lists an optional Wi-Fi adapter. The details for each range are shown in the key points above.
Can a split system replace a gas heater in Melbourne?
Often, yes. Reverse cycle split systems heat as well as cool. As a VEU accredited provider (A2261) we can check whether replacing your existing heater may be eligible for a Victorian Energy Upgrades discount.
What warranty applies to Mitsubishi Electric split systems?
Mitsubishi Electric Australia states that M and S series models come with a warranty period of 5 years on parts and labour for residential application. Conditions are on Mitsubishi Electric Australia's warranty page.
Request a quote
Choosing a Mitsubishi Electric split system for your Melbourne home? Contact EZYAIR or call 1300 EZYAIR (1300 399 247).